Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
903 Wild Rose Ct
RECEIVED February 5, 2009 FEB 0 9 2009 TM . EAGAN ~ Mr. Dave westermayer ENG9NEERING DEPARTMENT Engineering Technician City of Eagan N o r t h f i e 1 d 3830 Pilot Knob Road M i n n e s o t a Eagan, Minnesota 55112 Re: Onsite_Qbservations 903 Wild Rose Court ~ Lana surveying Eagan, Minnesota MBI #N5423/N9032 Civil Engineering Geotechnical Engineering Dear Mr. Westermayer; Construction Material Testing Environrnentai seNioes As discussed in our letter of January 29, 2009, we were present to observe the excavations along the west side of the building near the watermain easement. This letter is intended to discuss what we observed and address the issues of frost penetration and undermining of the watermain pipe. Observations were completed on February 4, 2009. Background The background information listed in our previous letter listed the bottom of footing elevations at 881.00. While that is the actual lowest footing elevations, the footings in the west corner of the house are at an elevation of 884.67. A new map is attached showing the footing elevation in relationship with the watermain. Frost The issue of frost penetration into the soil was based mostly on the lack of cover that might be present after the excavation for footings occurs. The contractor was able to excavate a near vertical wall in the clayey soils as shown on the attached 1604 Riverview Lane map. We measured the edge of excavation as being nearly 8 feet from the center Northfield, MN 55057 Tel. 507.645.0964 of the watermain pipe. This means there is over 8 feet of horizontal soil Fax. 507.645.2842 e-mail. mlc@mbi-nf.com Established 1995 Equal Opportunity Employer 903 Wild Rose Court. Eaqan, Minnesota MBI #N5423/N9032 Paae 2 protection for the watermain. The vertical soil cover is listed as a minimum of 7%2 feet, therefore the watermain should be suitably protected from frost unless additional excavations occur. Underminina Excavation of the footings on the west corner of the building was to a depth of 884.67. The watermain is located a minimum of 7 feet below grade (per City of Eagan drawings) and therefore would be estimated at an elevation of 881.83 (per attached drawing). The excavation for footings was not below the elevation of the watermain and therefore undermining of the watermain is not an issue. Comments Based upon our excavation observations, it is our opinion that frost penetration and heaving of the watermain or undermining of the watermain by the footings are no longer issues at this site. These issues should not need to be re-addressed unless additional excavations occur in the west corner of the building. Our scope of services was limited to the above mentioned issues of frost and undermining of the watermain. Soil observations for foundation support were not completed and are generally not done for single family residential buildings unless the contractor or building inspector note poor soils. A~l Osborn, P.E. Geotecnical Engineer MWO/mwo Cc: Brian J Smith - Brian J. Smith Construction Inc. City of E_ Me To: Builder, Property Owner, Future Homeowner and any other interested parties involved with the property. From: Dave Westermayer Date: January 29, 2009 Subject: Excavating and grading on new home site-903 Wild Rose Ct. The property at 903 Wild Rose Ct. is surrounded by drainage and utility easements with City infrastructure located within those easements. Running along the western property line the City owns an 8" water main. The front corner of the proposed home is shown to abut up to the easement line; this will put it approximately 91/2 feet from the water main. As I write this memo the entire month of January has been below freezing with only a slight moderation in temperature forecast for the foreseeable future. The water main must have a minimum of 7.5 feet of cover, both vertically and horizontally to prevent freezing. It is our concern that when the excavation takes place for the basement and footings we will no longer have sufficient cover to prevent the pipe from freezing. In conversations with the builder it is anticipated that at best, it will be 1 to 2 weeks before backfilling operations can take place. Unfortunately, we are not able to isolate that line and feed the neighborhood from a different direction because there are several homes hooked up to that stretch of water main. In addition to the exposure we are also concerned that during the excavation process, depending on the type of soils encountered, undermining of the water main may take place. Should this happen it could easily lead to the pipe breaking. The main will also be at risk during the excavation process as heavy equipment may be ruruling on or near it that could cause damage. Finally, care must be taken during the backfilling operation, especially with the possibility of frozen soil being placed and compacted near the main. All of these scenarios are very possible at this time of year and are of great concern to City staff. According to the as-builts on file with the City the water main is to have a minimum of 7.5 feet of cover, this does not mean that it can't be deeper though. In conversations with the City utility locator who was recently on site locating the water main, he was getting readings of depths between 8 and 15 feet deep. With current technology these readings cannot be trusted unfortunately. Because of this uncertainty the contractor must expose the water main in the area nearest the front westerly corner of the home in order to verify the water main depth. If it is found that the water main is in fact deeper than 7.5 feet then the Building Inspections Department will require extra depth footings 20 feet in both directions from the corner of the building. The depth will be determined by the depth of the water main. A 1:1 slope is required between the water main and the footing. As a result of these concerns the City is requiring that every precaution be taken to protect this pipe until backfilling operations are complete. As a precaution, the City is requiring the owner to provide us with an engineer prepared plan that will detail the precautions that will be taken. In addition, we are requiring a$10,000 escrow be deposited with the City to cover the costs of increased City inspection time that will be required to monitor the water main as well as any potential repair costs. Shortly after backfilling operations are complete and assuming there are no problems with the water main, the City will return the balance of the escrow, minus the inspection fees discussed above. Along the south side of the property there is a 30 foot drainage and utility easement with a City owned sanitary sewer line running through it. This line is buried over 20 feet deep. Should this line require excavation for repair or replacement we will need to access the entire easement. I'm concerned with the grades on the south side of the property, running from the garage to the south property line. The City standard for maintainable slopes is 3 ft. horizontal to 1 ft. vertical (3 :1). It appears to me that a significant portion of the south foundation wall of the garage will need to be left exposed and utilized for a retaining wall. No external retaining walls will be allowed within the easement. This issue should be addressed at the time the footings are constructed in order to allow for this situation. If there are questions or should it become necessary to meet on site to discuss things further I can be reached at 651-675-5641. C. Russ Matthys, City Engineer Wayne Schwanz, Superintendent of Utilities Dale Schoeppner, Chief Building Official Terry Zelenka, Building Inspector 903 Wild Rose Ct. parcel file F~ :s~ ~ PL g~0 c1q i 90. ~ 0 ; Permit 0 City of ~a a~ Permrt . 19.50 Fee: 3830 Pilot Knob Road 0 ~ Ea gan MN 55122 ( f i Date Rec ived: •~`U j Phone: (651) 675-5675 I67 :2`q 7 i Staff: i Fax: (651) 675-5694 O~O~ ~ ~ ~ ~ 2009 RESIDENTIAL BUILDING PERMIT APPLICATION oate: site Address: Tenant: O(:p Suite RESIDENT / OWNER Name: S~-OIIJ5 41 C=N C!OMPPy--1 V Lt.e- Phone: 11012 -44~ V Address / Ciry / Zip: Pv RDX 240-1 Z!Y NPLZ V+,,-~ MN Tsi Z4 Applicant is: Owner X Contractor TYPE OF WORK Description of work: tj ljw 5/~c.o F-Yim I~ Construction Cost: 4-3(' Svo Multi-Family`Building: (Yes / No )C ) CONTRACTOR Name: ~~Ajr Aiutt &-wPA-N~ 1-L-~- License 2Z&A4s<3 Address: Pd '2;dX ~7s? City: ~PLF 4N--~ State: WN Zip: SS iLQ Phone: ui7-'440 `?64 o Contact Person: iwi ~pjmi'Ut COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING Minnesota Rules 7670 Cateaorv 1 Minnesota Rules 7672 Energy Code • Residential Ventilation Category 1 Worksheet • New Energy Code Worksheet Category Submitted Submitted (4 submission type) • Energy Envelope Calculations Submitted In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes _,~LNo If yes, date and address of master plan: Licensed Plumber: f4MU Phone: Mechanical Contractor: ` Phone: Sewer & Water Contractor: V-:/(A4+b0tj Phone: l~'2-41q-~ i7-`'1 A~-Iz) ° NOTEs°P?a`r?s artd supparfing documents'thafyou, suBrrrtit are considered to be pubtic infprmation. Portions of : . , the infor?rtation may,be c/assified as non-publlc if you,provide specific reasons tha# would ormit the,-City,to , coticlude'ttiat the ~ are frede~°s'ecrets. I hereby acknowledge that this information is complete and accurate; that the work will be in onformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work 's not astaFt-witlae~t..~permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval,pf ans. ~ x ~N/l d~YZVM.NI X Applicant's Printed Name Applicant' S gn re ~ Page 1 of 3 ~ DO NOT WRITE BELOW THIS LINE SUB TYPES _ Foundation _ Flrepiace _ Porch (3-Season) _ Storm Damage _7X Single Family _ Garage _ Porch (4-Season) _ Euterior Alteration (Single Family) ~ Multi ~ Deck _ Porch (Screen/Gazebo/Pergola) ~ Exterior Alteration (Muiti) 01 of , Plex Lower Level Pool Miscelianeous _ Accessory Building WORK TYPES ~ New ~ Interior Improvement _ Siding ~ Demolish Building* _ Addition _ Move Building _ Reroof _ Demolish Interior _ Aiteration _ Fire Repair _ Windows _ Demolish Foundation _ Repface i Repair _ Egress Window _ Water Damage "Demolition of entire building - give PCA handout to applicant DESCRIPTION Valuation ~ 047 0 Occupancy MCES System Plan Review Code Edition Y,14t N~Ut,? 7 SAC Units (25%_ 100%-k Zoning City Water Census Code f}~ / Stories Booster Pump # of Units Square Feet ~ PRV # of Buildings Length ~ Fire Sprinklers Type of Construction Width -,r-•~-- REQUIRED INSPECTIONS __)!L Footings (New Building) Sheetrock Footings (Deck) ~ Final / C.O. Required Footings (Addition) Final / No C.O. Required )r, Foundation HVAC Drain Tile Other: Roof: _Ice & Water _Final Pool: _Footings _Air/ sts Final Framing Siding: _Stucco Lath Stone Lat _Brick Fireplace: ~Rough In _,'Air Test ~Final Windows ~ Insulation /K Retaining Wall ~ Meter Size: Reviewed By: T ~ . Building Inspector RESIDENTIAL FEES Base Fee Surcharge j( ~5"; c•~ 7 ~ ~ J ~j~~ Ol W Plan Review ~ ~ d i g ~ ~ MCES SAC q 7 4 t ~ City SAC Utility Connection Charge S&W Permit & Surcharge ~ Treatment Plant Copies v TOTAL r ~ ~ ~ 3r ~~y~rl , REScheck Software Version 4.1.0 Compliance Certificate Project Title: RAMSEY RESIDENCE Report Date: 01/02/09 Data filename: D:Wrchitecture\CADD\Stone Arch Company\Ramsey\Ramsey.rck Energy Code: 2000 Minnesota Energy Code Location: Dakota County, Minnesota Construction Type: Single Family Giazing Area Percentage: 14% Climate Zone: 2 Construction Site: Owner/Agent: Designer/Contractor: 903 Wild Rose Ct. Bruce Lehrer Eagan, MN Bruce Lehrer, Architect 3908 Georgia Ave. N. Crystal, MN 55427 763 535-2746 astrigal@yahoo.com Maximum UA: 685 Your Home UA: 546 = 20.3% Better Than Code . Cont. . Assembly . . . D.. Perimeter . Ceiling 1: Raised or Energy Truss 1854 40.0 0.1 44 Wall 1: Wood Frame, 16" o.c. 4750 19.0 0.1 241 Window 1: Above-Grade:Vinyl Frame:Double Pane with Low-E 592 0.330 195 Door 1: Glass 50 0.330 17 Door 2: Solid , 25 0.070 2 Basement Wall 1: Solid Concrete or Masonry 693 11.0 0.1 40 Wall height: 9.0' , Depth below grade: 8.0' Insulation depth: 9.0' Floor 1: All-Wood JoisUTruss:Over Unconditioned Space 228 38.0 0.1 6 Floor 2: All-Wood Joist/Truss:Over Outside Air 27 38.0 0.1 1 Fumace 1: Forced Hot Air85 AFUE Air Conditioner 1: Electric Central Air13 SEER ' Cbmpliance Statement: The proposed building design descri ed h e is consistent with the building plans, specifications, and other cafculation he permit application. The propos buil ing has be esi n meet the 2000 Minnesota Energy Code , requii~ments che Version 4.1.0 and to comply with the an atoryre u' s listed in the REScheck Inspe 'on C ecklist. ~ ` A'A Na ~ Ti Si ure Date RAMSEY RESIDENCE Page 1 of 1 City 0f Eam Ma To: Builder, Property Owner, Future Homeowner and any other interested parties involved with the property. From: Dave Westermayer Date: January 29, 2009 Subject: Excavating and grading on new home site-903 Wild Rose Ct. The property at 903 Wild Rose Ct. is surrounded by drainage and utility easements with City infrastructure located within those easements. Running along the western property line the Ciry owns an 8" water main. The front corner of the proposed home is shown to abut up to the easement line; this will put it approximately 9%z feet from the water main. As I write this memo the entire month of January has been below freezing with only a slight moderation in temperature forecast for the foreseeable future. The water main must have a minimum of 7.5 feet of cover, both vertically and horizontally to prevent freezing. It is our concern that when the excavation takes place for the basement and footings we will no longer have sufficient cover to prevent the pipe from freezing. In conversations with the builder it is anticipated that at best, it will be 11/2 to 2 weeks before backfilling operations can take place. Unfortunately, we are not able to isolate that line and feed the neighborhood from a different direction because there are several homes hooked up to that stretch of water main. In addition to the exposure we are also concerned that during the excavation process, depending on the type of soils encountered, undermining of the water main may take place. Should this happen it could easily lead to the pipe breaking. The main will also be at risk during the excavation process as heavy equipment may be running on or near it . that could cause damage. Finally, care must be taken during the backfilling operation, especially with the possibility of frozen soil being placed and compacted near the main. All of these scenarios are very possible at this time of year and are of great concern to City staff. According to the as-builts on file with the City the water main is to have a minimum of 7.5 feet of cover, this does not mean that it can't be deeper though. In conversations with the City utility locator who was recently on site locating the water main, he was getting readings of depths between 8 and 15 feet deep. With current technology these readings cannot be trusted unfortunately. Because of this uncertainty the contractor must expose the water main in the area nearest the front westerly corner of the home in order to verify the water main depth. If it is found that the water main is in fact deeper than 7.5 feet then the Building Inspections Department will require extra depth footings 20 feet in both directions from the corner of the building. The depth will be determined by the depth of the water main. A 1:1 slope is required between the water main and the footing. As a result of these concerns the City is requiring that every precaution be taken to protect this pipe until backfilling operations are complete. As a precaution, the City is requiring the owner to provide us with an engineer prepared plan that will detail the precautions that will be taken. In addition, we are requiring a$10,000 escrow be deposited with the City to cover the costs of increased City inspection time that will be required to monitor the water main as well as any potential repair costs. Shortly after backfilling operations are complete and assuming there are no problems with the water main, the City will return the balance of the escrow, minus the inspection fees discussed above. Along the south side of the property there is a 30 foot drainage and utility easement with a City owned sanitary sewer line running through it. This line is buried over 20 feet deep. Should this line require excavation for repair or replacement we will need to access the entire easement. I'm concerned with the grades on the south side of the property, ruruiing from the garage to the south property line. The City standard for maintainable slopes is 3 ft. horizontal to 1 ft. vertical (3 :1). It appears to me that a significant portion of the south foundation wall of the garage will need to be left exposed and utilized for a retaining wall. No external retaining walls will be allowed within the easement. This issue should be addressed at the time the footings are constructed in order to allow for this situation. If there are questions or should it become necessary to meet on site to discuss things further I can be reached at 651-675-5641. C. Russ Matthys, City Engineer Wayne Schwanz, Superintendent of Utilities Dale Schoeppner, Chief Building Official Terry Zelenka, Building Inspector 903 Wild Rose Ct. parcel file ' LOT SURVEY CHECKLIST FOR RESIDENTlAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: Ld T ~I 1 S DATE Q SURVEY: Jl/lfl09 LATEST REVISION: /IZ3zO2 m a~ c ca , ~ U O z Q DOCUMENT STANDARDS p? • Registered Land Surveyor signature and company „B ? p • Building Permit Applicant ~ ? ? . Legal description ig ? ? • Address ,9 ? ? • North arrow and scale AI&O ?X • House type (rambler, walkout, split w/o, split entry, lookout, etc.) ~Z p? • Directional drainage arrows with slope/gradient % ~t,,0 ? .9 • Proposed/existing sewer and water services.& invert elevation .g ? ? • Street name ,0 • Driveway (grade & width - in R/W and back of curb, 22' max.) ;r p ? • Lot Square Footage ? • Lot Coverage ELEVATION-S Existin ~ ? p • Property comers ~ p ? • Top of curb at the driveway and property line extensions ~ p? . Elevations of any existing adjacent homes 'W ? ? Adequate footing depth of structures due to adjacent utility trenches ? p . Waterways (pond, stream, etc.) Proposed ~ p ? • Garage floor ~ ? ? • Basement floor 'z p p • Lowest exposed elevation (walkout/window) ~ ? 4 • Property corners ,pf . Front and rear of home at the foundation PONDING AREA (if applicable) ? ~ ? • Easement line ? ~ ? • NWL ? 'K 0 • HWL ? pl ? • Pond # designation X p p • Emergency Overflow Elevation , ? .0 p • Pond/Wetland buffer delineation y . Shoreland Zoning Overlay District y ~ • Conservation Easements DIMENSIONS ~ ? 0 • Lot lines/Bearings & dimensions Right-of-way and street width (to back of curb) • Proposed home dimensions including any proposed decks, overhangs greater than 2', por~ches, etc. (i.e. all structures requiring permanent footings) 'z ? • Show all easements of record and any City utilities within those easements _ g p ? • Setbacks of proposed structure and sideyard setback of adjacent existing structures ~ p• Retaining wall requirements: X)o '~J Akj/S 9.l10r,/ed r?~ ~~-+f~~'s• Reviewed By: Date G~ O~ G:/FORMSBuilding PermitApplication Rev. 11-26-04 . . Certifica te of House Loca tion for: ' STONL' ARGH COMPANY L,L, C. Property Address: 903 Wild Rose Court 8 ,8 S 89'46'31 " E tA'0.00 $$9.1 Property Description: 885•o~ E o F ee5.1 sg o S$4 9 Lot 11, Biock 1, ROYAL OAKS, I N ~ according to the recorded plat thereof, I ~ c~ ~ Dakota County, Minnesota. Wood Fence ~ Drainoge. an_ tility Easement M Also showing the location of a proposed M o T house staked thereon. 3e9 Maximum O..~,...,.._:q.;~~ ~999l ~ - +884.5' - ~ : . . ^ I 4 -f- 884.7 ~ B OCK a,, r~~ o L + ~uv Q~~ a (T@ 885.00C~'OO 4.1 ~ E.O.F. pU ~4Q~0 D I A N ^ I 885.0 ~op~ ~sr t 884.1 ~ Scale: 1 inch = 30 feet b 8510 , b~\ ~ Lot Coverage: o 9 l~ g$4~$ ~ + 8 3.4 ~ Lot Area = 24,075 sq. feet Z I $85.$ ~ gg~, j jA $~$,65\ ~ 3 House & Garage = 3,242 sq. feet s. s4 , 7.2 S s 'yo~ 8$5.1 6~ 884.40 ~ Total Impervious = 3,242 sq. feet 9~,~1 ~ 0, 0 ~ 8$5 Coverage =13.47 % ` 889.63 I •$$9.1 ^O s~ ~.9 8 5A ~,y +g 3 O o ~ Benchmark: Top Nut Hydrant, Corner of s.ao~o~~O 4~ Wescott Sq. & Ivy Lane: Elev. =874.15 gg0.0ay 884'9 888.0 c Z 891.3 \ O I • f0 ~ O`I ~~O(~~ C n Sanitary Sewer Invert = 881.0 i 1$90•7 A cO 890.6 N per Grading Plan - Verify in field .0 - W = Existing City w~ /~1,2 ~ant 884.8 890.4 N ~ Watermain er •ry - Grading PI n y~q~ ~ 894.0 N Garage 890A j g.~ ~o Water ~ 891. 40 , Va lve o~+ 891.7 2$.45883. 10.0 ~ ',V.,'~ti'~~~ d ~ 'L• ~ ~ 1.5/ 881.71 89 . S' ~ ~ ~ 83.23 , ~ 889.31 w ~ ~ ~ and 30.e7j i 87 7 ~ ~ \ 91. O e~ Q~ 6 o >prainoge - ~ Q ~ ' _ - ~ 76.9 881.8 .g3•18'11" W 136. 68 ~ 891.6 g - - S 91,6 t 883.8 892 ~ Exis ting House ' ' 0 = Iron Pipe Monument O= Set Iron Pipe at Building Offset 891.6 = Existing Spot Elevation ~ O = Proposed Spot Elevation Proposed Direction of Drainage Existing Sanitory Sewer Manhole By ~ _ w - u - v v - = Proposed Water Service D - ss - ss - ss Proposed Sanitary Sewer Service _ I/z9 09 Proposed Garage Fioor Elev. 894A AN Proposed Top of Block Elev. (Gar) _ ~ 894_33 Proposed Lowest Level Elev. __V 885.67+ /heroby ceitify fhal this p/an, speallcafion, or reporf wesprgparodbyme or undermydiriscl Proposed Top of Footing Elev. = 885_34 supends/on and that/ am a da/yLiraensed Land Surveyorunderthe /aws ofthe S'late of Mlnnesola. D-Eq~,~,MAR H. SCHwANz . n•o._>/>4/09 ~M1 S< De~ J~ `"''s~ LAND SURV~'YORS, ING. Reulsed >/2,3/09 LtCENSED ~ DRAWN DATE 14555 So. RoBERT TRAIL ° LANp - JM 1 /08/09 RoseMOUNT, MN 55068 e ~ SURVEYOR ~ N^445817 APPROVED DATE 651-423-1769 o ~ °e . • A•,e ,,.°~0,~,•° MAS 1 l14/09 RAMSEY RESIDENCE M•a~ SCALE SHEET PROJEGT NO. B ManrrA. Schwanz, LandSarv~yt~ 1~~ - 3O~ H09001 Minnes010License No, 458>7 ~ t Name: ROOF Cuatomer.Dakota County Lu w0:315093 TI:K Qty;6. TC FORGEAXL. R'7DCSI Cr TC: 2x 4 SPF !13/q2 (N) lixialysis based oa Simplifi:ed Analoq Model, _ .._==JoinL Locations^~^----. 1- 2 177 0.04 C.52 0.56 A HC: '2x 4 SPF 017N2 (N) MULTIPLE IqAaCASES This dosign is tha ' 1) 0- 0- 0 4) 16- 7-10 7) '0- 0- 0 2- 3 -612 0.01 Cs:77 0.78 B WB: 2x 3 SPF STUD (N) Ccivosite zeault of muTtipla loadcases. 2) 5- 4- 3 5) lb- 7-10 3- '4 -411 0:00 'G.80 0.81 H 2z 4 SPF 011N2 (N) 3-6,4-6,4-5 End vertical(a) noC dosiqnod :or expoaure 3) 10- 8- 6 6) 8- 3-13 2x fi SPF 1650F-1.5C 0-0 to letQral wind p=as3ure. ROTI.I, pESICN LOADS Hottom rhord haa been loaded with 10 psF This truss ia designed in apcozdance with Uniform PLF Fro.m P1,F Tc ?C FORCE AXt. 8ti6 C$3 Cr liva Saad agplied non-concusrantly: ehe 2006 intarnation3l Rasideatial Code TG Ve=t L+D -90 - 1- 0- 8 -90 10- 8- 6 7- b 402 4.04 'C:78 0.83 H. All G(7FPRESSION Chords aro aasumad to ba 6ectians It502.11.1 And R802.10:2 and TC Vert IhD -90 10- 6- b -90 17- 1- 2 6- 5 17 O.AO C:78 0.78 8 continuously braced unless noted othan+isa. roferenced siandazds, U.N.O. BC Vert LtD -20 0- D- 0 -20 16- 7-16 NndLod per ASCE 7-05, MWFRS%CSC, V. 90.7ph, Sracing Schedulo; in-Plant Quality Apaurapoo with'Cq = 1.00 H= 23.0 £t, I= 1.00, Exp.Cat. C, Kzt= 1.0 Chords Max O.C, Fro.m To In-P1ant Quality A§suzaace, pes Web FORCE Web FORCE B1d Type= mncl I.e 16.6 ft W= 16.6 ft Truss TC 24.0" 1D- 8- 6 17- 1- 2 sna. 3.2.4 of TPI-1-02, for jo3nt'(s): 7- 3 -187 5.- 4 746 in Efm sona; TCDIs+ 6.0 psP, eCDt,~ 6.0 psP 'rtaba Brace Pt Joint to Joint 2,6 7- 2 -784 .5' 0123 --°Mhx. REACTIONS PEA BEARING iACATION""- 1/2 2- 7, 2- 6, 4- -6 --"--"GLAHAL t+WC DEFLECTIONS'---'-_-- 2- 6 276 0- 4 -222 x-I'°c BSet Vert Horiz Uplift Y lype 1/3 3- 6 yy TL 6- 3 c305 0= d -650 D- 1-12 1 1047 320 -48 H Pin 8xaainq shoxn is for visual purposea only: in./Ratio in./Ratio Jnt(s). 16-10-10 1. 934 0 -315 T H Roll Continous lateral bracing sytached to I:Span -0.19/999 -0.34/573 4-3 :PROVIDE VPLIFT CONh'ECTION FER SCgEDULE ~ either edqa ot web{s} shovm OR a T-2arace, Horiz.- 0:06 0.67 NA See explanatian ot RepeLitiva PROVIaE.HORi20NTAL CONNECTION PER 5CHEDULE nailad Elat to edga°.of web with 3.5"x 0.135" Long tarn dvflecCion fsaLOr = 1:50 Member Factor, Cr, on aails spaced B" o:c. 2-hrace miisE oxtend reveree aida of paper or. at least 404 of web length and be same siza, speciea, and grade as wab.. TEC Fo=m 8.14.20071, 2x6 T-S:ace zequired on any web over 141-011. Truss Renair; (TI: `K) Sheet 1 of 2 Also see sheet 2 of 2 ~ 10-8-6 6-4-12 ~ 2 3 0_,j8 ~ er~uod a3 r ta.on ~ sxs ~ 68 {x12 Z C) m ~ r''j~ i 0 v1 ~D rl'A .13-6'11 t.,rd , + f~~ 1- i-a ~ f f ~ N i T 4-7- C.t , ~ - ; ;u ~ 3x8 " n 3x4 3x8 3x4 (U~ ; ~ ~ ~ e r t 1047a s.i~i~~ 9340 >:on,~ i 6- 7-to 1 t~ f~ ; . , . . . . ~ £XCEPT A3 SHOWN PLATES ARE 'MiTek MT20 (Rl- I- 8) :SCalc = 0.1250 WARNING: Eng Job; WO: 315693 Rf'AD ALL NO ES'Qb HIS SBCET COPY OE 7N2.+ 6RhH2NG TO pLGZVEN ?O ERECTSl7G C6NTW+CTOR ERACIF70 xnR,vZhC - - DW4 : TZ : -H ~ Pr n~.lm.;nm~7uJiaiipp4 t u„nr ~ 4 u. ltr r ~~~Rru E ' t ~ i~ M Lu,p ~ d~2n Ds9r.•~SLS Ckbk' 3 A• • /9/20Q9 OTTM Mni5t rd 1 lJ bl rihli ~ niul r Ji wt:lirll n~ isn.la fp~., firdl i . ain.n ni n1t t.~ TC L3ve 35.0 psf I.br DF.: 1.15 {eif iiuhr t~ ryi ni.wxS.P~ulunt,.7~iwY.ifow~P~mindin,,7tluLcialfSMtA(Amyn ~a„e W. .,nn,vviv, TC Dead 10: 0 psf Plt DF: 1.15 BC Live 0.0 psf O.C.::2- 0» 0 IRC-06/TPI-02/NOS-05 BC llead 1 0.4. pef Coda:: D47-RES TOTAL 55.0 sf v5.5.19 7962727 >DA.ign:.~Hntrix Analysis Pzofslc Path: £:Ntru3jobs\315000\315093\ROOE\K,prx 1Y0: 3151193 'I'I; K Qt}: G Raftez Length Left a 13-11- 2 Rafter Length:Rtght = 6- 4-12 TG: 2x 4 SPF #1/H2 (N) PaaR to 1leel Laft = 17- 2-11 SGr 2x 9 S8F k1/H2 (f7) Squara Check Zeft = iB- 5- 0: Square Ch'sck Riqht = 21- 9- 6 WB: 2x 3 SPF STUD (N) Laadinq = 35/10/0/10 2- Or 0 O.G. OF 6 1.15/1.;15 PMBF,= 1.15 3x 4 SPF.k1/q2 (N} 3-6.,4=6,4-5 2x.5 SPF 165OF-1_5C 0-0 In-Plant Quality Assurance, per TrussRepair: (TI: K) aec. 3.2..4 of TPI-1-02, For joint(s Need to trim 0-1-0 off of the left end heel. Z;fi` Temporarily shore truss to assure straight building lines upon completion of repair. 1. Using a sawsall to eut through steel plates, carefully cut and remove 0-1-0 from end of truss taking care not to damage the remaining nortions of the truss. 2. Install neiv 2x4 #1/#2`SPF ta inside of end vertical as shown, cut encls accuratcly to bear. 3. Apply %x" APA rated 32/16 shcathing to each face af truss in (2) locations shown, fastening with (12) bd common nails ner lineal foot into all members, installed in a staggered pattern. Gx8 _ Gx13 Sheet Z of 2 Also see sheet I of 2 J i,, f ~1 ~ N 13- G- tl 13< 6- U cq 1.5x1 i ~ J A .~p. z -t-7-0 srs s.a lZ., 104743.50" 934i~.i.00" ^3 C) I G- 7-lU - ~ 7 Cr 3 1 a-3,: I6-2-10 +t'-)- ~ EXGEPT AS SHOWN PLATES ARE MiTek MT20 SC~~Ic=11:?~11t1 ~ , NasnQ: ROOF Customer:Aakota County Lu Wp:315093 TZiKG. Qty;2 TC FbRCE AX3. BNU CS2 Cr TC; 2x 4 SPk' N1/#2 (N) Analysis based.on Sizmilificd Analoq Modal. - ' ---doint Iacaeions=----=~ .1- Z. 197 0..040.52 0.56A BC! Zx d'SPF A1/q2(N) MIJLTIPLEIqAI)CASES Thisdesi(jii is.thQ 1) 0-.0-0 -Ay 16- 7-20 7) 0--0-.0 2- 3 -612 0.01 0.71 0;.72 AWB: Zx 3 SPF STUD (N) cc+npositc sesult of multiple loadcaaas', 2} 5- 4-.3 5) 16- 7-10 2x 4 SPF ql/q2 (N) `3-6,4-6,4-5 Snd vertical(s) not.deaiqned for axposure 3) 10- 8-"6 61 8- 3-13 3- 4 -411 D.00 0.80 +O.B1 8 2x 6 SPF 1650F-1:5C 0-0 to lateral aind pre?sure. T4TAL DESIGl7 LOADS G8: 2x 3 SPF STUD- (N) This tru3s ia derlignQd in accordance yith IUniform PLF From pLF Tp BC FORCE ARL eNA t5I Cr 2x 4 S8F q1YN2 (N) 0-0 the 2006 international Rasidential Code TC Vart L+D -40 - 3- 4-.8 -90 10- B- 6' 7- 6 402 0.04 0.78 0.83 8 Botten chord has bean loadod xith 10 p3f soetions R582.11.1 and R802.10.2 and TC Vert L+D -90 10- 8- 6 -90 17- 2 6- 5 17 0,00 0,78 0.79 g live load appliad non-concurreatly, reEerenced standards, U:N.O; HC Vart L+D -20 0- 0-'0 -20 16-°7-10 Al1 CCY3PRESSION Chords ar6 aaqu,Ted Eo'be Sracinq Schedulo: In-Plant ¢uality. Asaurartco wieh Cq = 1.'00 continuouely bzsiced unless no:ed othezr+ise. Chords Mau O.C. From To In-Plant Quality Aasurance, per web FORCE Wob EORC& Hnd2.od per ASCE.7-05; NrTF3t3/C6C, v= 90mph, TG 24.0" 10- 9- 0 17- 1- 2 acc: 3.2:4 of TPI-1-02; 1or juint(s): 7- 1 -187 6- L" 746 H= 23.0 ft, I= 1.00, Exp.Cat. C, Kzt= 1.0 Hebs HraCe Pt Joint to Joznt 2,6 7- 2 -784 5- 0 123 $ld TYPe= encl 16.6 ft W= 16.6 ft Trnss 1/2 2- 7;2- 6,d- 6 ----M.NC. REACTIONS PER HEAitING LOCATION----- 2'-.6 276 0- C -222 ia EAID xono; TCDI.= 5.0 ps:, HCD1= 6.0 psf 1/3 3- b X-Loc BSat VQrt xoriz,Uplift Y Type 6- 3 305 0- 0 -650 This tzuss has boon designed £or wind Hracinq shoxn is for visnal purposea on1y. p- 1-12 1 1047 320 -48 8 Pin in the plane of tha truss oalyl!! ~ Continous lateral 5racing attachad tc 16•14-10 1 934 0 -315. T H Roll either edqa of web(s) shorm OR a.T-b=ace, BROYZpE UPLIFT COId7ECTIdN PEA SCBEDULE Seo,eacplanation o£ Rapotitiwa- nailad flat to adge of Neb with 3,5"x 0.1351' PFtOVTDE AOR22oD7TAL'CONNEGT20N PER SCHEDULE MerborFactos,Cr; on -nails'spacnd 611 o.c.T-brace muot;axtend --------GLOSAL t.Nf DEFLECT20N3--------- xevarse sido of paper or at least 909 of web leaqth and bo Qama LL TL siza; speciea, and grade as wab, ia./Ratia fn./Ratio Jnt(s), TEC £ozm 8.1C.2007.. 2x6 T-BZaco requi,red on any web over 14'-0". I.Span -0.19/999 -0:34/573 4-3 Truss Rcnair: {TI.: KG) xoriz. 0.04 0.07 Nk S}ICQt l of 2 Long term do£lection taetor = 1.50 Also see sheet 2 of 2 tb-&=G 6-4-I2 1 2 3 t0.0U 3r8 Gr8 6si2 f, T' ~x~+i t~ 13- C- U 1.5x4 I 11`-~~5~4 7 Z3 ~ ~ ~ I ~ ' I 714 - ~ ~ 4-7- Q J 3 S I 3a4 3a8 3.0 . , ~ j f . R " ' ` 2330 s:nn" 11147ti3.50" I6-7-10 iG- .f0 ' C03M.ETIC PIJ:T£S j88)1.5x4 8) ° Z., EXCEPT liS SHOWN PI.ATES I+RE M'aTek MT20 Scnlc = 0.0938, WARNING: Enq Job: WO`. 315093 AEA17 ALL NOTES ON Tk125 SNEET ACOM OF T1YIS DRAHING-TO $E GZVEN.T(7 . a-+ erscazr~c co~cron mwsirro wruuisxc Dwg.: T2: KG ~ " II ny.hnin+~dwih~ ngintrecinl~ L JLniypnJlh g1 l g hl ~ iithn. hufAnp +lceigum1 .:66mwlw &.rcJMtlr h6JJ:np.k Ur+nn k lr. :>r,~.inei,.. .D.sgnr:BLS- Chk: 3/9/2009. ry n fu I iht lu I'll g1.;ih.Cti i ni~4 ' t n4rl.~llia +p`.r. 1 1plr..~•,tlimu OTT~~ akk ul«•e1.4r11) i.a TC Ltve 35.0paf Lbr. Dfi': 1.15pee f~i~ Er ~,i.wn..~~:~n.LtiF.kitr.reiTc~!•Isie~na:i i:..fi~: I-a J aNSYII)ik~rfli~ Pl! DE' 1.15 Iei,, u.~~~~~ns~ u, TC Dead 10.0 psf . BC Liva 0.0 psg O.C.. 2 0-,0 IRC-06/TPI-02/ND5-05 DC nead 10.0 psf Code: M-RES TOTAL 55..0 s€ v5.5.19=7462729 Design: MaErix-7+nalysin. ProfiloPatih:-F:\tzu.sjoba\315000\3I5093\ROOF\KG.pzx. W'U: 3150I3 Tl: K(`, Q1y: 1 Raftor bength Left = 13-11-,2 RaPter LQngth Right = fi- 9=12 TC: 2x 4 SPF #1/N2' (N) Yeak to tieal `Le:t = 17- 2-11 BC: 2x 4 SPF 91/N2' (N) Squa,re Chack :LQ_°t =18- 5- D Square Check Right ='21- 9- 6 WB: 2x 3 SPF STUD (N) Loading = 35/10/0/10 2- 0- 0 O.G. DF = 1.15/1.15 RMIDF = 1.15 2x 4 SPk' #1/#2 (N) 3-6,9-6,4-5 `2x b SPF 1650F-1.8C 0-0 T'russ Renair: (TI; KG) G8: 3 SPF SPF N STW (N) 2x 2x 4 1/#2 (N) o-o Neecl to trim 0-1-0 off of thc left end heel. Tn-Plant Quality Assuranae; pe= sec. 3.2.4 of TBZ-1-02,'for jaint(s): Temporarily shore truss to assure straight building lines upon comPletion of repair.. i;e 1. Using a sawsall to cut through stcel plates; carefully cut and removc 0-1-0 from end of truss taking care: not to damage the remaining portions of the fruss, 2. Instoll neFV 2x4 #11#2 SPF to inside of enci yerfical as shown, cut ends accurately to`bear. 3. APply'/:" APA rated 32116 shcathing to each face of #russ in (2) iocations shown, fasten:ing with (12) 6d common aails pcr lineal foot into all members, instailed in a staggered pattern. Shcet 2 pf`2 6x8* ~ ~Xiz Atso see shcet 1 of 2 , ~ q 3zi ~ R CA ~ .C~. : " c14 13- G- U ! 3- G- 0 z ~ ;C) 1.5x4 i l 5- 4 ....y r; ,T c ,r rs rs 4•. 7• 0 . S ~ r M.. r~ ' 3z8 3x~1 ' : ~ ~ ;:a 47 GJ LJ rC'~:!. - . 047A.50 934ti 5:001* ~ f6- 7-ao :7 - A 6 4 S i s , 16-7-10 ~t1-9- EXCEPT _AS SHOGiN'PLATE8.ARE MiTOk ;MT20 Scair=O:2500. ~o : Memo 5201 Eust kiver Rtxtd Suite 308 Mrrrneamlix. Mit:izesnta :55421 Plzo,re: t763j 571-2500 1"ax:. (76_1)571-1I68 Dat@: ~ay 18y 2009 To:: Jim Iirumm (Stcrne A:rch Custam Homes) From: Tfan Sargeant~ Subject: Ramsey Residence, 903 Wild Rase Caurt, Eagan,11!fN Project R09.00152 Ulteig Engineers, lnc. designed the foundation walts in the garage that were exposed on che outside more ihan the't}+pical toundatian for the residenee under construciion at the atsave referred adc[ress. The foundation wall systerrt was designed sueh that the wall is to span verticaily with dowals tying inta the faoting and slab at the tap. The wall was cracked during fhe backfilling due tti a (ack of temporary bracing. The contractors remaved the back fitl and tied.the w311 to the front foundat'tan wall using a syst.eny of steel plates and cables. T'he filt was replaced and the garage slab was installerl with.the haQk dowe(s into the foundation waEt. The fqttndation wall distress wa4 described as a large diagonul ceack near the tap m'rdd1e section of the wall which was clcised when the avall was pulled back into placed. Ulie;ig has reviewed the fiiiai con;ctruction canditian and does nat recomniend any further eortective measures atthis time. The crack in ttte wall will be cnverECi wittt backfilt ox7 the inside cif the. garage crack aratl wifh the hause sicl'ing an the Lxtcrior side. Therefores EhEI?L' IS il4 I]et'.CI tO C(74Xy IIljC:CC tI14' cracfc. The wall system is structurally aciequate ance the dowels at the top of the :wall were i.nstalled into the garage slab. Please call nae'if you have any questions. I hereby cerfify that this plan, speciricatiocr or report was prepaneri by me ar under rny direct supervision and that I am a duiy l'rcensed professionat engineer under the laws of the State of Minnesata, Daniel Sa ant Uate: 0511$/09 Minnescrta Registration No. 26817 20' EASEMENT N 1-1- 10' SEPERATION 890,00 GROUND ELEVATIQN 885,00 889,00 I 888.00 887,00 7.5' EXCA ATION 2 0' E A S E M E N T 886,00 LowER FLaaR 885.67 885,00 ( 884,00 S BOTTOM OF FDOTING 884,67 883,00 ~ I 882.00 8' WATERMAIN Z' OVERSIZE 881,00 ESTIMATED BOTTOM I OF PIPE 881,83 FINISHED FLOOR: 885,67 880,00 I BOTTOM OF FOOTING: 884,67 879,00 878,00 890.00 10' SEPERATION g~~,oo 876,00 ERPST PENETRATIDN REVIEW I I I 20' EASEMENT 8910 1-0- 10' SEPERATION 890,00 GROUND ELEVATION 889,00 888,00 ~ P/ 887,00 7.5' EXCA ATION 886,00 LOWER FLOOR 885,67 lbj 885,00 4- 884,00 BOTTOM OF FOOTING 884,67 ~ 883,00 / 882.00 B` WATERMAIN- 881,00 ESTIMATED BOTTflM P L A N V I E W OF PIPE 881,83 ~ 880,00 879,00 ' 878.00 NO UNDERMINING OF WATERMAIN IICCURRED ~ e77,00 EXCAVATIDN WAS NOT BELOW EXPECTED WATERMAIN DEPTH I ELEVATIONS TAKEN FROM CERTIFICATE OF 876,00 ' HOUSE LOCATION AND ARCHITECTURAL PLANS U N D E R M I N I N G R E V I E W I hereby certify that this plan, specification ar report was prepared by me or under my ~a survepin8 I ceo~teechntcet ring direct supervision and that I am a duly Urban-Land constructinn i~ateriai W''ATERMAIN R j~ EW Licensed Professional Engineer under the P1~~H T~~ laws of the State of Minnesota. Consuiting - Civi1 Landsca e Eagineerfng Arckuteure 903 WILD RO S E C OURT MARK W. OSBORN. P.E. 1804 RtvervieR Lene xortMield, MN 66067 EAGAN MINNESOTA elephone 607.895.0984 Date 2/5/09 Reg. No. 41362 T ~ Facelmlle 507.6452842 ' mD1@mcgh4eDetta.cam Address: 903 Wild Rose Court Zip: 55123 Permit: 88093 THE FOLLOWING ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON : Yes No Comments Final grade - 6" from siding Permanent steps - garage Permanent steps - main entry Permanent driveway Permanent gas Retaining Wall or 3:1 Max Slope Sod/Seeded lawn Trail/curb damage Porch Lower level finish Deck Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. BUILDING INSPECTOR: G:\Building Inspections\FORMS\Checklists /1 INSULATION INSPECTION CHECKLIST FOR RESIDENTIAL BUILDING PERMITS PROPERTY LEGAL: B t CI PROPERTY ADDRESS: 903 ; t Rb5' U k j INSPECTOR: t?tt~ ~4, ~Gl ,fit) INSPECTION DATE: o Z Z SITE GRADING ? ? All slopes 3:1 or flatter? ? ? Slopes steeper than 3:1 require retaining wall. Are retaining walls present? ? ? Does grading conform to As-Built Grading Plan 1 foot approximately)? ? ? Does perimeter grading tie in well with adjacent properties/undisturbed land? ? ? Is there proper grading and/or drainage around Lookout or Egress Windows? EROSION CONTROL ? ? Is Silt Fence (or approved equal) installed and in good working order? ~I ? ? Is Sod/Fiber Blanket installed behind curb? ? ? Is the Rock Construction Entrance/Driveway installed and in good working order (proper type/size of aggregate, clean-not covered with soil, etc.)? ? ? ? Is temporary vegetative cover w/ mulch present? ? ? ? Is permanent vegetative cover w/ or w/o mulch present? (circle one) CITY EASEMENTS AND UTILITIES jJ ? ? Are all easements clear-no part of any building/deck/porch/retaining wall/etc. encroaching in easement? ? ? Are catch basins present within the property or in the street in front of the property, if so are they clean, do they have the proper erosion control in and/or around them? ? ? ] Does the property have an Emergency Over Flow (EOF)? This can be found on the Certificate of Survey. If so, is it present and has it been graded properly? MISCELLANEOUS ITEMS ? ? Is there tracking present on Public Right-of-Way/Street from construction site? ? ? Is the driveway at the proper width at ROW line? (22 ft. max.)(Curb stop is at ROW line) ? ? Is the site clean, no trash and/or construction debris lying around? ? ? Was the proper type of building constructed according to the approved grading plans? (LO, WO, FB, R, etc.) Use BLUE or BLACK Ink For Office Use I317'City ofEaali Permit#: �j� t Permit Fee: 3830 Pilot Knob Road VI (0.('I Eagan MN 55122 '( Date Received: _ c -1 1 Phone:(651)675-5675 Fax:(651)675-5694 Staff: � J 2017 RESIDENTIAL BUILDING PERMIT APPLICATION n )Z3 Date: .�-Z 3 -)7 Site Address: 9 C 3 to 1 d° £c; � Unit#: Name: 13 r;e4 -1 J- leek Vo //' "ict..4, Phone: &12-201- 0 Resident/ K/� Owner Address/City/Zip: 903 wi Cd Ofe Cf` ��e1 Ct A SX/ ?3 Applicant is: Owner Contractor ✓ Type of Work Description of work: ...-:✓Pc/�"u )/l u7,�y t q ) - -1 Construction Cost: x•--51 LA.3CJ. 00 Multi-Family Building: (Yes /NoX) Company: Veld 1 {p / r3cds- Contact: T0 f h ✓//Cly Address: 30 i C'jd >G /eCity: gU�r4J1,r/ 1 Contractor 17n // State:ty�lrr Zip: ST-337 Phone:61Z-363 -1)47-Lail: J0L il CA)V4!/7pccS1 Cyff//te�rr License#: 11)/`) Lead Certificate#: /I/�` If the project is exempt from lead certification, please explain why: Q ( / 0A Ne i,df S'i,�.�®rt�1 1�7 40 l J .r ba c4Yr/ce. COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan? Yes No If yes,date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities_ www.gooherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. +l i v 1/CC& x Aar Applicant's Printed Name 11!!!"a. 's Signature Page 1 of 3 minty t.onnecuon a.narge S&W Permit&Surcharge Treatment Plant f Copies TOTAL Page 2 of 3 q03 a a core c+- , - DO NOT WRITE BELOW THIS LINE 17 37Y SUB TYPES Foundation _ Fireplace — Porch(3-Season) _ Exterior Alteration(Single Family) Single Family — Garage _ Porch(4-Season) _ Exterior Alteration(Multi) _ Multi _ Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of_Plex _ Lower Level \r Pool _ Accessory Building WORK TYPES /� xNew _ Interior Improvement _ Siding _ Demolish Building* Addition — Move Building — Reroof Demolish Interior _ Alteration _ Fire Repair _ Windows ___.. Demolish Foundation Replace _ Repair _ Egress Window _ Water Damage Retaining Wall *Demolition of entire building-give PCA handout to applicant DESCRIPTION "` Valuation ri61 0 )3 OccupancyDN./Ct.-le MCES System Plan ReviewCode Edition (,4'!$ D °"` SAC Units (25%_ 100% �) Zoning111:4-- City Water Census Code ///"' Stories Booster Pump #of Units Square Feet PRV #of Buildings Length Fire Suppression Required Type of Construction v6 Width REQUIRED INSPECTIONS Footings(New Building) Meter Size: Footings(Deck) Final/C.O. Required — Footings(Addition) Final/No C.O. Required Foundation Foundation Before Backfill HVAC Gas Service Test Gas Line Air Test Roof: Ice&Water _Final Pool: )cFootings V Air/Gas Tests ) Final Framing 30 Minutes 1 Hour Drain Tile /� — Fireplace:_Rough In _Air Test Final Siding: Stucco Lath _Stone Lath _Brick_EFIS Insulation Windows — Sheathing Retaining Wall: Footings,Backfill Final Sheetrock Radon Control — Fire Walls Fire Suppression:_Rough In_Final Braced Walls Erosion Control Shower Pan Other: Reviewed By: It ,Building Inspector RESIDENTIAL FEES Base Fee pot_ Surcharge t_ Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit&Surcharge L Treatment Plant02/4"0 Copies TOTAL Page 2 of 3 POOL PERMIT — APPLICATION SUBMITTAL REQUIREMENTS Address: C-t0 J I la R,6,Ke , Applicant Name: 1-60A �� 51 JIkb1l Pim v1 GENERAL INFORMATION x ¢ b o z ❑ ❑ Applicant name and contact information _-Er ❑ ❑ Property owner name 8 ❑ ❑ Address of property JD ❑ ❑ North arrow, scale (1" = 30' or 40') --la ❑ ❑ Site Plan, drawn to scale showing location of house,pool, and other existing or proposed structures, including retaining walls and fences. ..— ❑ ❑ Location and name of all streets adjacent to property --3` ❑ ❑ Directional drainage arrows (existing and proposed) ,.l3 ❑ ❑ Lot Square Footage —� ❑ ❑ Lot Coverage ELEVATIONS Existinq A ❑ ❑ House corners )21i ❑ ❑ Property corners ❑ ja ❑ If applicable, ground elevation at each end of retaining walls and at wall's greatest height Proposed ❑ ❑ Finished pool deck corners ❑ , ❑ Top of proposed retaining walls (if any) and at each different elevation(if it changes) Zi ❑ ❑ Pool bottom(or max. depth) DIMENSIONS Existinq X ❑ ❑ All property/lot lines ❑ ❑ All Easements on the property Proposed ❑ ❑ Pool ❑ ❑ Pool plus integrated deck/patio rEi ❑ ❑ Shortest distance from outside edge ofpool d to lot lines and house Reviewed: h Name. Date G:FORMS/Poo1 Permit Checklist/11-20-12 • rt x rt O 00 ON ..s C n A ...TTT m 1 JAr am' LL..--.�� 8 ,,,,,_....4 , Z. ro / f n N ^s 1 01 0 0 JJ 4 C ! 0 0‘ R° \ C> p g OJ a Ts -e n ,IT e $ ./'' g. c`` O o a �, . \4 * , o CI z c CD g ro Z rt n a) IND rn n m n c ° N 3 NNi i i ° z ow Cu N �Oo X w �. F+ O ,_ °1 * P = l< < ^ P. N O ut co n 7a O if !D N (J1 6D 31 n o DK `< " N.. —p �R co m o m K O03 0-7 O .4. co 0 0 to co Z c fl1 C7 n co W I1I � t RECEIVED ' . tiN081017 Certificate of House Location for: STONE ARCH COMPANY LLC• C=A';s i,`5 �,1 �,�/`�ac ' 1 Property Address: t h E 5 yL 903 Wild Rose Court 884.8.-- S 89'46'31" E 0.00 1.1 889.1 h?viCe • r Property Description: 885 or 882.5 -loci I I S z Z 4.v7 • •E.O.F. 885.1 885.0 ® 1 N ,\ Lot i 1,Block 1,ROYAL OAKS, i T 9; N according to the recorded plat theteo, i i i N ti j(2� fide / f tilit Easement ,, u Dakota County,Minnesota. Wood Fence �� Drainage. an Y I Also showing the location of a proposed lcn e (C4 v. e.6JI house staked thereon. "� r r r ; a3:a Maudatum Slopes r V t 07.. _'"�V11&$Will t` T J + 8@4.5 ,Y r- /�v o/ ,s over 3 Be�::..,uIr i � •• IL��, .i ,. ` ;'j 4) ''- 0;11 be f'Jrn �e7 I /�€G'./' tXLsi''iy �^ p:. lap . ?_ 'au, FT vac /-''R Ii fi r?.`" ) � 4,. Pii`1� cy h C� //t e Q��-�? NEM Q'�� " 4 885.80Q;o , 01' \ E.Q.F.j^ ) -.1 • / Scale: 30 feet n • `++i' \'c�# ���4.1 t\` ). 0 P�; 1 !Sy:.m :,: $ 884.9, / Lot Coverage: .1 CD//, Ix 884,8 \ + 8f 3.4 t L its f -'S d e A. Lot Area=24,075 sq.Leet 2 `885.8, 885.1 °A 8 65\• t `' House&Garage= 3,242 sq.feet 1 .S8851 \ \---•A i,i� • //, d`� 6.64 i" ..7,2 - , yfl , 88440 t / l` t i e r`h q� Total Impervloue= 3242 sq.feet !'t(. ./�^ A `se 885.9 S' ? • 1 l d ) n l Coverage=13.47% 889.. 1 ,':889.1 oA s/O y ci '� /''. (.(/t//��nQs t- pts 01 I S /! / 7" eertchmark:Top Nut Hydrant,Cornerr a �4890 Po �1 884.9 (}��j} � !�(� V trdescatt Sq.it ivy Lane:Bev.=874.15 • 890.0 .S.O /�o r-► 41 ti, �p //� /�i $91,3 \ 0 ' 6 :90.8 �S� of « v ,eai(,y'eiI- elect /2"sr/ Sanitary Sewer Invert s881.0 ��� 1 890.7w\ c.,..; to per Grading Plan - Verify in field /' / 4 J, a, O -AL.-,1-("i •/ •4,9 LO -W- = Existing City tij //1,2 42Pnt 890.4 s ra `.4.8 T• f it �, e [ Watermain per •ti ,� / 90.0 .-•-tr fe v61 )r`4•1 d r Grading Pian �C9 ;//4' s94.Q N Garage (� ? } :•'i.1 �ii`U`cG • gS'AL�5a0-' Water "�. 891. // .. • . 891.7 ze.458: - 40 Li12,-. ah h'K ©E S( , Valve t ,- i 1,11,o�1 c . .. to.Q� 881.11 Ferri Ce �7c C�irrc/r `r ..,1. r/• cpe _ _ 1 .fi '' 8 -F s,67" ! - .il. ��5. \ 889.31 and tl 87�1 � '(' ''' '6 p >piraino9e _ 17 J t / �Jc� i / S y :'1. ' jY� 7 >��. 876.9,< - 861.8 1 , �' `\...�•� �..�� sT t g'11" W 138•t313 0.1 Yr 891.6• - 863.8 *ID 892.0 Existing kouse c� • = Iron Pipe Monument O = Set Iron Pipe of Building Offset %' (›S ' 891.8 - Existing Spot Elevation O= Proposed Spot Elevation ' 'ED -= Proposed Direction of Drainage `� r t ® = Existing Sanitary Sewer Manhole LU �' S _s--v-v-v- = Proposed Water Service �y .[j�� 4 -" - � -�-ss-s- = Proposed Sanitary Sewer Service Dom. Proposed Garage Floor Elev. _ 894_0 •� oa,Adda.�CditdCa wan. Proposed Top of Block Elev. (Gar) = 894.33- Proposed Lowest Level Elev. a 885.57 {hbrabydatt�plen, t�A' 885.34 • IL irepatwas peperedbyme°ruse•rmydrad Proposed Top of Footing Else, m 1 pi Ir' super bn end Mot t BM a okay LkwirsedLand Surveyor' laws ofthe State of AI6ArrB i0ihr. ,"�,ti,,,=",rt,,, a DELMAR H. SCHWANZ r .5 (1,2319 ,�� p,.... pi,.. `ii'i(i LAND SURVEYORS, /NC. • RevAsed 1/13/09 .:-9 ' ,L� DRAWN DATE 14555 So.ROBERT TRAIL • LICENSED „ai LANC' .tM 1/08/09 ROSEMOUNT,MN 55068 SURVEYOR r• APPROVED DATE 651-423-1769 P. g �• , 45817 ..•��= �.- s ,.•40.x' MAS 1/14/09 RAStsEY RESIDENCE �'�'SaiS r�'rj40.+ SCALE SHEET PROJECT NO. i'Tr 1"=30' H09001 MarAA,safl. ..4 Load Sonmpr - Use BLUE or BLACK Ink For Office Use Permit : ! -� City of Eag, # eC F : . o b Permit ee 3830 Pilot Knob Road Eagan MN 55122 Date Received: Phone: (651)675-5675 Fax: (651) 675-5694 L Staff: 2017 RESIDENTIAL PLUMBING PERMIT APPLICATION Date: a/c28//1 Site Address: (4O3 (,(Ji là Ro6e C-c. Tenant: Suite#: Resident/Owner Name: gclChh voil +MYL r\ Phone: Address/City� /Zip: Name: A. lo'1t.11d o.,11a Jdn5 PiU,YY\bi tl d License#: PC k)4/49Contractor i�� CU1 kk,YY1* j(-t S City: j i.ilnk 0,(1116A64/\ Stater Zip: rya 6/g--7/Pho6/g--7/ Cl"�� b Contact: I Email: aSY1StD I u Ntb�hoh. ® rr Cc.w Type of Work A.New _Replacement _Repair _R/ebuilld _Modify Space _Work inR.O.W. Description of work: LL L >/, G���� � AILI/Z/52/471(1/1'7 RESIDENTIAL Water Heater Water Softener Lawn Irrigation( RPZ/_PVB) Permit Type Add Plumbing Fixtures( Main/_Lower Level) Septic System New Water Turnaround _Abandonment RESIDENTIAL FEES: $60.00 Water Heater, Water Softener, or Water Heater and Softener(includes State Surcharge) $60.00 Lawn Irrigation (includes State Surcharge) $60.00 Add Plumbing Fixtures, Septic System Abandonment, Water Turnaround*(includes State Surcharge) "Water Turnaround (add$280.00 if a 3/4"meter is required) $115.00 Septic System New(includes County fee and State Surcharge) TOTAL FEES$ CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordancetwith the approved plan in the case of work which requires a review and approval of pl ns. x tYICYI ) S )o-in A x Applicant's Printed Name Applican i9 nature FOR OFFICE USE Reviewed By: " "' Date: Required Inspections: Under.Ground Rough-In Air Test Gas Test Final Meter Related Items: Meter Size .Radio Read Manometer Staff: PERMIT City of Eagan Permit Type:Building Permit Number:EA143863 Date Issued:06/29/2017 Permit Category:ePermit Site Address: 903 Wild Rose Ct Lot:11 Block: 1 Addition: Royal Oaks PID:10-64800-01-110 Use: Description: Sub Type:Fireplace Work Type:Gas Fireplace (new) Description: Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to concealing. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 3,000.00 Fee Summary:BL - Base Fee $3K $88.50 0801.4085 Surcharge - Based on Valuation $3K $1.50 9001.2195 $90.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Brian R Volkmann 903 Wild Rose Ct Eagan MN 55123 Fireside Hearth & Home 2700 Fairview Ave N Roseville MN 55113 (952) 985-6675 Applicant/Permitee: Signature Issued By: Signature cEIVED Com'' RE Use BLUE or BLACK In110) JUN 1. 9 2017 r For Office Use ' 4 1 U y Permit s / 7 N" f Cl y of �a�a� Permit Fee: (G /` 7L. ! 3830 Pilot Knob Road Eagan MN 55122 Date Received: ON! (651)675-5675 Fax:(651)675-5694 Staff : VII 2017 RESIDENTIAL BUILDING PERMIT APPLICATION 06/28/2017 903 Wild Rose Ct Date: Site Address: Unit#: Brian and Jessica Volkmann 612-201-0784 Name: Phone: Resident! 903 Wild Rose Ct. Eagan, MN — 1 Owner Address/City/Zip: X Applicant is: Owner Contractor Basement Finish Type of Work Description of work: 10000 X Construction Cost: Multi-Family Building:(Yes /No ) South Metro Custom Remodeling Inc Adam P Warpeha Company: Contact: 1813 Wyndam Dr Shakopee Contractor Address: City: MN 55379 612-916-691E southmetroremodel@gmail.corr State: Zip: Phone: Email: BC#628112 NA License#: Lead Certificate#: If the project is exempt from lead certification, please explain why: House built in the last 5 years COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan? X Yes No If yes,date and address of master plan: Soland and Sons Plumbing 612-718-8489 Licensed Plumber: Phone: Anderson Air 612-719-2450 Mechanical Contractor: Phone: NA Sewer&Water Contractor: Phone: NA Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific masons that would grit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan;that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit;that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. Adam P Warpeha x x Applicant's Printed Name Applicant's Signature Page 1 of 3 ii Esc- �,� 9)Z2 •Z ll DO NOT WRITE BELOW THIS LINE / � SUB TYPES Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family) Single Family _ Garage Porch(4-Season) Exterior Alteration(Multi) _ Multi _ Deck — Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of_Plex ✓ Lower Level Pool _ Accessory Building WORK TYPES _ New _ Interior Improvement _ Siding _ Demolish Building* _ Addition _ Move Building _ Reroof _ Demolish Interior Alteration _ Fire Repair _ Windows _ Demolish Foundation Replace _ Repair Egress Window _ Water Damage Retaining Wall *Demolition of entire building-give PCA handout to applicant DESCRIPTION S �� Valuation ) (1 J 0 Occupancy .C." MCES System Plan Review Code Edition 4 r ( SAC Units (25%_100%y) Zoning f/ City Water Census Code Stories Booster Pump #of Units Square Feet PRV #of Buildings Length Fire Suppression Required Type of Construction 7-6- Width REQUIRED INSPECTIONS Footings(New Building) Meter Size: Footings(Deck) Final/C.O. Required Footings(Addition) )4 Final/No C.O. Required Foundation Foundation Before Backfill HVAC_Gas Service Test Gas Line Air Test Roof: Ice&Water _Final Pool:_Footings _Air/Gas ests _Final iFraming 1( 30 Minutes_1 Hour Drain Tile )c Fireplace: V Rough InP` Air Test x Final Siding:_Stucco Lath _Stone Lath _Brick_EFIS Insulation I\, t Windows Sheathing Retaining Wall:_Footings_Backfill_Final Sheetrock Radon Control Fire Walls Fire Suppression:_Rough In_Final Braced Walls Erosion Control Shower Pan Other: Reviewed By: ` , Building Inspector RESIDENTIAL FEES ?? Base Feetrf,S t Surcharge f Plan Review V V MCES SACr3",I C ' f �` City SAC U, f '?;`I%' Utility Connection Charge t./` IltY S&W Permit&Surcharge Treatment Plant / Copies q /29y20 -- / D TOTAL / Page 2 of 3 PERMIT City of Eagan Permit Type:Building Permit Number:EA157616 Date Issued:08/29/2019 Permit Category:ePermit Site Address: 903 Wild Rose Ct Lot:11 Block: 1 Addition: Royal Oaks PID:10-64800-01-110 Use: Description: Sub Type:Reroof Work Type:Replace Description:Does not include skylight(s) Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Valuation: 5,000.00 Fee Summary:BL - Base Fee $5K $118.00 0801.4085 Surcharge - Based on Valuation $5K $2.50 9001.2195 $120.50 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Brian R Volkmann 903 Wild Rose Ct Eagan MN 55123 Evergreen Construction Company Inc 1200 Centre Pointe Curve, #175 St Paul MN 55120 (651) 209-3130 Applicant/Permitee: Signature Issued By: Signature