4402 Woodgate CoveCity of Eagan
Eagan,
PERMIT
City of Eaan
Permit Type: Building
Permit Number: EA098578
Date Issued: 04/13/2011
Permit Category: ePermit
Site Address: 4402 Woodgate Cove
Lot: 000 Block: 000 Addition: Woodgate Cove
PID: 10-84650-01-010
Use:
Description:
Sub Type: e-Reroof
Work Type: Replace
Description: House & Garage
Census Code: 434 -
Zoning:
Square Feet: 0
Construction Type:
Occupancy:
Comments:
If there is no ice protection inspection prior to final, the contractor must meet the inspector w/ a ladder and flat bar.
Pictures are not acceptable in lieu of inspections.
Carbon monoxide detectors are required by law in ALL single family homes.
Fee Summary:
Valuation: 3,000.00
BL - Base Fee $3K
$88.50
Surcharge - Based on Valuation $3K $1.50
0801.4085
9001.2195
Total: $90.00
Contractor:
Sela Roofing Remodeling
4100 Excelsior Blvd
St. Louis Park MN 55416
(612) 823-8046
- Applicant -
Owner:
Christophe R Lotzow
4402 Woodgate Cove
Eagan MN 55121
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Applicant/Permitee: Signature
Issued By: Signature
2005 RESIDENTIAL BUILDING PERMIT APPLICATION ~
City Of Eagan
C~~ (0 3830 Pilot Knob Road, Eagan MN 55122
Telephone # 651-675-5675 FAX # 651-675-5694
New Construction Requirements Remodel/Repair Requirements OKrce llss ~niv
3 registered site surveys showing sq. ft. of lot, sq. ft. of house; and all roofed areas 2 copies of plan Gert`iifiSiirVey:Recd':` .;:'':;Y;;`:: N
(20°a maximum lot coverage allowed) 1 set of Energy Calculations for heated additions Tree Pres,Plan;Recd, ._Y _N.
2 copies of plan showing beam & window sizes; poured found design, etc. 1 site survey for adddions & decks 7ree Pres f2equired': X>N
1 set of Energy Calculations Addition - indicate if on-site septic system On-site,S.epiic System: .Y' N
3 copies of Tree Preseroation Plan if lot platted after 7/1/93
Rim Joist Delail Options selection sheet (buildings with 3 or less units)
Date 3 / ) 0 /os- Construction Cost
Site Address Z Unit/Ste #
Description of Work
Multi-Family Bldg _ Y~ N Fireplace(s) X 0 _ 1 _ 2
Property Owner N1(-j n ~~mQir\ Jal q irj LAZO' ilJ Telephone # (6 C I) 4"~--r ~ -
Contractor 1~OhX_' Q~~~ biY\.a -W kiv[),r~- _
Address ' City
State Zip Telephone # ( )
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
- Minnesota Rules 7670 Categorv 1 Minnesota Rules 7672
Energy Code Category Residential Ventilation Category 1 Worksheet • New Energy Code Worksheet
(~I submission type) • Submitted Submitted
• Energy Envelope Calculations Submitted
Have you previously constructed a building in Eagan with a similar plan? _ Y _ N If so, 25% plan review
fee applies.
Licensed Plumber Telephone # ( )
Mechanical Contractor Telephone # ( )
Sewer/Water Contractor Telephone )
I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate;
that the work will be in conformance with the ordinances and codes of the City of Eagan and the State of MN
Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a
permit; that the work will be in accordance with the approved plan in the case of work wfiicli;requ~ir',es a revie and
approval of plans. L 5 V't~ ~
~
kffl"l "(I v
plicant's Printed Name p licant' Si at e
K~etsT6p{~L ~ZeW ~ - -
OFFICE USE ONLY
Sub Types
? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg
? 02 SF Dwelling 0 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi
O 03 01 of _ plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea. ) ? 33 Ext. Alt - SF
? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 Multi Misc.
? 05 03-plex ? 11 10-plex ~ 19 Lower Level ? 24 Storm Damage
? 06 04-plex ? 12 12-plex Plbg_Y or _ N ? 25 Miscellaneous
Work Types
? 31 New 4#35 Int Improvement ? 38 Demolish Interior 13 44 Siding
? 32 Addition O 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair
33 Alteration ? 37 Demolish Building" ? 43 Reroof ? 46 Windows/Doors
? 34 Replacement 'Demolition (Entire Bldg) - Give PCA handout to applicant
Vaiuatiun 69 z-a- 'wi Occupancy MCES System
Census Code Zoning City Water
SAC Units Stories Booster Pump
# of Units Sq. Ft. PRV
# of Bldgs Length Fire Sprinklered
Type of Const Width
REQUIRED INSPECTIONS
_ Footings (new bldg) _ FinaUC.O.
_ Footings (deck) FinaUNo C.O.
_ Footings (addition) Plumbing
_ Foundation ~ HVAC
Drain Tile Other
Roof Ice & Water Final Pool Ftgs Air/Gas Tests Final
~ Framing _ Siding _ Stucco _ Stone _ Brick
Fireplace _ R.I. _ Air Test _ Final _ Windows
~ Insulation _ Retaining Wall
Approved By: Building Inspector
•
Base Fee
Plan Reg ew
MC/ES SAC
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
License Search
Copies
Other
Total
2005 RESIDENTIAL PLUMBING PERMIT APPLICATION
CITY OF EAGAN
3830 PILOT KNOB ROAD, EAGAN MN 55122
651-675-5675
Please complete for modifications to existing residential dwellings.
Date . ~ 110 / 0~
Site Street Address woOl~ LL'T"~ ~-0 ~-1-1 Z f Unit #
Property OwnerNyi SfiR!'kr_ U,Y 15.1 bvvY1(~.Loiz QVJTelephone #(w)
Contractor Telephone # ( )
Address City State Zip
The Applicant is: ~ Owner _ Contractor _Other
Alterations to existing dwelling $ 50.00
~ Add plumbing fixtures (excludes water softener and/or water heater--complete next
section if installing these appliances).
_Septic System Abandonment
_Water Turnaround (add $125.00 if a 5/8" meter is required)
Other:
Water Softener Water Heater $ 15.00
_ new _ replacement
Lawn Irrigation _RPZ _PVB _new _repair _rebuild $ 30.00
State Surcharge $ .50
Total $
I hereby apply for a Residential Plumbing Permit and acknowledge that the information is complete
and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan and the plumbing codes; that I understand this is not a permit, but only an application for a
permit, work is not to start without a permit and work will be in accordance with the approved plan in
the eVent a plan is required to be reviewed and approved. _
e-Nn&l-~jisl 4 TZ-DUoI
rn a Lil,
Applicant's Printed Name pplic nt's Si at e
<
- _
Lv
\J -2 RESIDENTIAL BUILDING ~ ~ ~ S~
U Permit Application
City Of Eagan 90
. S~
' 3830 Pilot Knob Road, Eagan Mn 55122
Telephone # 651-675-5675 FAX # 651-675-5694 S.. (p~
New Construction Reauirements RemodeUReaair Requirements 0 ce Use Oni ~i,t,i,l_~l q
3 registered site surveys showing sq. ft. of lot, sq. ft. of house; and all roofed areas 2 copies of plan eR of Survey Recd
(20% maximum lot coverage allowed) ` 1 set of Energy Calculations for heated additions Tree Pres Plan Recd,
2 copies of plan showing beam & window sizes; poured found design, etc. 1 site survey for additions & decks 120>ee Pres Not Reqd
1 set of Energy Calculations Addition - indicate if on-site septic system _ On-site Septic System
3 copies of Tree Preservation Plan if lot piatted after 711193
Rim Joist Detail Options selection sheet ;bldgs with 3 or less units ~
- 3-1.~
Date ~ / d' 5' / Q 3> Construction Cost z a,
Site Address R Unit/Ste #
Description of Work °1,
Multi-Family Bldg N Fireplace(s) _ 0 _ 1 _ 2
Property Owner Telephone #
j~
--Al
Contractor
Address lL/)l ; a '14 cy - -0 . City S0
State 141 ~ Zip '5s07S Telephone # (45)) aY~' 9d-/ ~
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
Minnesota Rules 7670 Categorv 1 Minnesota Rules 7672
Energy Code CategOry . Residential Ventilation Category 1 Worksheet • New Energy Code Worksheet
(4 submission type) Submitted Submitted
• Energy Envelope Calculations Submitted
Licensed Plumber, ~Telephone j~763- ~Idf-/B3
Mechanical Contractor Telephone )bsr'~~5/ a /
n
a~ ~ 3~
Sewer/Water Contractor Telephone # ~63 ~-Y
6~ I
~ ,
~
~ 'I hereby apply for a Residential Building Permit and acknowledge that the information is comp and acc~rate;
that the work will be in conformance with the ordinances and codes of the City of Eagan-and- the Stat -e- MN
Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a
permit; that the work will be in accordance with the approved plan in the case of work which requires a review and
approval of plans.
C~~?- ~~eS -V . ~ 1--s k ~ ~
Applicant's Printed Nam.e Applicant's Signature
OFFICE USE ONLY
Sub Types
? 01 Foundation ? 07 05-plex ? 13 16-plex 20 Pool ? 30 Accessol Bldg
71- 02 SF Dwelling ? 08 06-plex 0 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi
? 03 01 of _ plex ? 09 07-plex ? 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt - SF
? 04 02-plex ? 10 08-plex ? 18 Deck ? 23 Porch (screen/gazebo) ? 36 Multi Misc.
? 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage
? 06 04-plex ? 12 12-plex Plbg_Y or _ N ? 25 Miscellaneous
Work Types
~ 31 New ? 35 Int Improvement ?38 Demolish (Interior) ? 44 Siding
? 32 Addition ? 36 Move Bidg. ? 42 Demolish (Foundation) O 45 Fire Repair
? 33 Alteration ? 37 Demolish (Bldg)' ? 43 Reroof ? 46 Windows/Doors
? 34 ReplaCemen 'Demolition (Entire Bldg) - Give PCA handout to applicant
Valuation ~ OV Occupancy MC/ES System
Census Code Zoning IQ City Water
SAC Units ~ Stories Booster Pump
Nbr. of Units Sq. Ft. ~ PRV
Nbr. of Bldgs i Length Fire Sprinklered
Type of Const N/ Width ~
REQUIRED INSPECTIONS
Footings (new bldg) ~ FinaUC.O.
_ Footings (deck) _ Final/No C.O.
Footings (addition) _ Plumbing
_X Foundation _ HVAC
Drain Tile Other
Roof Ice & VGater Final _ Pool _ Ftgs _ Air/Gas Tests Final
~ Framing _ Siding Stucco Stone
_ Fireplace _ R.I. Air Test _ Final Windows (new/replacement)
1r Insulation ~ Retaining Wall
7t
Approved By Building Inspector
Base Fee
Surcharge
Plan Review MC/ES SAC ~O
City SAC
Utility Connection Charge 91
99~
S&W Permit & Surcharge
Treatment Plant _ d
License Search t~Copies
Other
Total
~ I , I I I ~ ~vl / ?
0";
;
.~75 u I p12
• r~ Fora1 for use with Minnesota Rules part 767 j
~ 1& 2 Family Residenti a l " Cookbook" 11 th
a?~ ~ ~ ~ ! ~ •
1(~ ty '
SITE ADDRESS i
BUILDEA uat
~ l
7117-11
~ , .
~
;
Minimum Criteria: f.s~;
PI
Rim loist: R-19 insulatioe Foundaton Windows: In a~I . i. 'f air space, woctd or vinyl frame
Entry doors: I3/s inch solid wood with storm or better •'I ` i
i 1
~
STEP 1 Window & Door Area STEP 2 QalCuls 'ar ; as a' percent of wall
Total Window & Door Area in Sq. Feet Bax A(window ' '15or a) i~ r
wall area) time al the window and door area
WYNDOWS (including foundation windows): ide¢ by Bbx B(to ca l
Dimensions Qncy. Area as a percent of ' C).
~j
~'J~ t/
x n ~j t D Box A
C
h~ 2 0 Box s~
x "
~n x 110 ST D, ign eatures
nx~
~PT'It7N
ASSEMHLY
. x.
X FRAME wa?L
,
x
STAND i
! ~ II' N ~ i
X
g ADVAN
X CAVITY INSUL
X
DOORS: SHEA1'HING:
,ST N 5 X:
~ ~ 611 j01 0
w ~
IIOA X ~ ~ 1,0` o WINDOWS (exc t~ n I;on~ i~dows):
,
Total Area of ~A~r2A
Window & Doors
From the table, d t i;4h c~axirnum percent window
Ft. & door area for t qs~ i o~ i~,s silected; and enter the
Total Wa11 Area in Sq. i~
Wall Total Perimeter Height Area value in box D i,
ID
~b I I.I': i
Box C m il t or ~equal to Box D
Tota! Area QB
af wall
!I Ik II I(~;~~ ~
~
; LOT SURVEY CHECKLIST FOR RESiDENTIAL
BUILDING PERMIT APPLICATION
PROPERTY LEGAL: L
DATE OF SURV Y: Ih--ll-n ~
LATEST REVISION:
m
~
c
~v
L
V
~
'0
Q
0 Q DOCUMENT STANDARDS
~ ? • Registered Land Surveyor signature and company
? ? • Building Permit Applicant
G~ ? ? • l.egal description
0 ? • Address
? ? • North arrow and scale
? • House type (rambler, walkout, split w/o, split entry, lookout, etc.)
C-r)~/ • Directional drainage arrows with slope/gradient %
r~a~ o ? ? • Proposed/existing sewer and water services & invert elevation
6d' ? ? • Street name ,
d ? ? • Driveway
IV/ ? ? • Lot Square Footage
? cl • Lot Coverage
. ELEVATIONS
Existin4
~ ? ? • Sewer service (or Proposed)
P/ ? ? • Property comers
2/ ? ? • Top of curb at the driveway and property line extensions
?~j? • Elevations of any existing adjacent homes
? • Adequate footing depth of structures due to adjacent utility trenches
? V? • Waterways (pond, stream, etc.)
Proposed
2 ? ? • Garage floor
V ? ? • Basement floor 0/ 0? • Lowest exposed elevation (walkouUwindow)
~ ? 0 • Property comers
? • Front and rear of home at the foundation
PONDING AREA (if applicable) ? O/0 • Easement line ? V ? • NWL
? CRI ? • HWL
o [r7/ ? • Pond # designation
? Q~ ? • Emergency Overflow Elevation
? f~ ? • Pond/Wetland buffer delineation
DIMENSIONS
0 • Lot lines/Bearings & dimensions
fW • Right-of-way and street width (to back of curb)
D ? • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc.
~ (i.e. all structures requiring permanent footings)
~ fJ • Show all easements of record and any City utilities within those easements
? 0 • Setbacks of proposed structure and sideyard setback of adjacent exi ting structures
fr7~? ? • Retaining wall requirements, if any
Reviewed:
Name Date
G:/FORMS/Building Permit Applicatlon
i
Cex•ci.ficate of House Location For: H03039 .
~
Equa.l. Access Hanes
DELMAR H. SCHWANZ
'LANOSURVEVORS.INC.
, Registered Under Lews of The Stete of Minnesote
14750 SOUTH ROBERT TRAIL ROSEMOUNT. MINNESOTA 55068 651/423-1769
SURVEYOR'S CERTIFICATE
Address: 4402 Woocigate Cove ,
9 = Fourv~d iron pipe monumP.nt
Set wood hub at bui.lding offset
1=Existi nra spot elevation
(~D = Proposed elevation
~ = Proposed direction of drainage
Lot Area = 11,546 square feet SCALE: 1 INCH = 30 FEET
Hotase & Garage Area = 1,236 square feet House Zype: Tuck Under
Service Invert Elev. = 927.3 --t:
(i~ Y) ~
930.2
~
936 . 5 S89' 44' 41 "W 97 . 40 930.9
05E ANp UTILITY EASEMENT
Q ,
~N 10 30
9A2.9 e _
V937. 1 ~ 934.6
~ L O T 1 \ tD 931. 3t
+ N ~
JBLOCK I \932_ ~
1 . ~
~1. 946,7 ~ ~Z 943. 1
948.5
4A
tD ~ 948.2 22 t
~ ' pP~s~~ 946.0 939.6\ +~q 932.7
947 . 5 k \ PP `~33. 8 'J
\ 44.7
942.3 a
E \ ~UgE + 3- d 933.2 \
~ a
. ~ ° 'tnN
942.7 + \ ~ m~ .M 937.+~ \
\941 1'1
PP~E ~ p 0 934.3 ~
!"P,
37,8 Z
o~~
ATER ~
940.6 9.4 937. vA 934.6
~ • 6p? 9~1 G
s3s.y Q6 09 ~
~ ~ 938. 1 3 .7
9 8 .1'
1 V~ 0 13
~ SO' 08' 00
P-~ o
L-7.96 r
R=45.00 O~O o
1 '`'~esA''. ,•'WM;^ ...,-u~„A'~i<.k;~'N{l ~
roK
Proper.ty Description:
Lot l, BioG)c 1~; WOODGATE COVE, according to the Proposed garage floor elevi,, 4;w:~~' F,
recordP.A plat thereof, Dakota County, Minnesota.
Proposed top of block elev.
Also s Iowing ttie location of a proposed
house staked thereon. Propo-ed 1'st 1?~re_ e_l
Yv .ev_
X"`1,~~AI I IEf 11S ~ /~,/4
I hereby certify that this survey, plan. or report was prepared by me or under my direct supervision and
that I am a duly Registered Land Surveyor under ~ DELMAR H. tne laws of the State of Minnesote. s SCHWAiVZ ~ ' '"`F;'`f~~,~~"'i`' , ?
s ' $6a5_ Delmar H. Schwanz
Dated April 11, 2003 '
Minnesota Registration No. 8625
~1(~~~l~~
utnnli
l
Site address: 4qo ~ w O 0 b-V'L Lot I Block ~ Subd.
On April 15, 2000 the Minnesota Energy Code, Category I Building Requirements for insulation protection, air
tightness, and ventilation, was adopted. As a result, the City of Eagan is requiring that the following information be
submitted prior to issuance of a Certificate of Occupancy.
_ This structure: is constructed to meet minimum requirements of the Mn Energy Code, Chapter 7670
OR
_ This structure: will be constructed to meet more restrictive requirements of Chapters 7672 or 7674
APPLIANCE GAS ELEC MANUFACTURER MODEL BTU'S VENTING TYPE
Water Heater 0c~7m4?\ s ff ap~ p6W4.1 Fumace
JL4MIL
Dryer
. VENTED
EXHAUST SYSTEM LOCATION TYPE MODEL CFM's YES NO
Kitchen kitchen AA-) Iqao x
Bathroom 1 m~IIJ -150 Y--
Bathroom 2
Bathroom 3
Bathroom 4
Other
VENTING
FIREPLACE S LOCATION GAS WOOD MANUFACTURER MODEL BTU'S DIREC7 ATMOS
MAKE-UP AIR MODEL TYPE CFM's
I hereby acknowledge that the above information is correct and agree to comply with the Minnesota Energy Code and City of Eagan
requirements.
2
Signature Date
Company me
* This form is the responsibility of the General Contractor.
Address: 4402 Woodgate Cove Zip: 55122
Lot: 1 Block: 1 Subdivision: Woodgate Cove
THE FOLC,OWING ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON ~
~
Yes No Comments
Final grade - 6" from siding
Permanent steps - garage
Permanent steps - main entry
.
Permanent driveway
Permanent gas
Sod/Seeded lawn
Trail/curb damage
Porch
Lower level finish
Deck
Fireplace
• Verify with your builder that roof test caps from the plumbing system have been removed.
• Turn off water supply to the outside lawn faucets before freeze potential exists.
• Call the City's Engineering Department at 651-675-5646 prior to working in right-of-way or installing
irrigation system.
~ BUILDING INSPECTOR:
CONTRACTOR:
Equal Access Homes
101 8`h St S, Suite 2816
Minneapolis, MN 55075
73&
2004 RESIDENTIAL PLUMBING PERMIT APPLICATION
CITY OF EAGAN
3830 PILOT KNOB ROAD, EAGAN MN 55122
651-675-5675
Please complete for modifications to existing residential dwellings.
Date (-e I ~ / o q
Site Street Address o Unit #
Property Owner vY 51 omf Telephone #((0-0 (0 I-I -~!?q I
Contractor 0~" Q-r Telephone # 05r}- 8~ ~i-k-(3b 7
~ 1~ Zi p---iy / ~ ~
Address ' ~a''~ City StateOThe Applicant is: _ Owner ~ Contractor _Other
Alterations to existing dwelling $ 50.00
_Add fixtures to rooms, excluding water softener and water heater
_Septic System Abandonment
_Water Turnaround (add $121.00 if a 5/8" meter is required)
Other:
~Water. Softener _ Water Heater $ 15.00
~ replacement _ additional
Lawn Irrigation System RPZ_ new _ repair _rebuild $ 30.00
State Surcharge $ .50
[T:o:tal
I hereby apply for a Residential Plumbing Permit and acknowledge that the information is complete
and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan and the plumbing codes; that I understand this is not a permit, but only an application for a
permit, work is not to start without a permit and work will be in accordance with the approved plan in
the event plan is required to be reviewed and approved.
Appl -d Applicant's Signature
n ,UN 0 9 2004
/ ~ t.
` 2005 RESIDENTLAL, BiTR,DING PERMIT qppI,ICATION
D,
City Of Eagan
3830 Pilot Knob Road, Eagan MN 55122
Telephone # 651-675-5675 FAX # 651-675-5694
New_Construction Reauirements
3 registered site surveys showing sq. ft. of lot, sq. ft. of house; and all roofed areas Remodel/Reoair Reauirements Office Use Onlv
(20% maximum lot coverage allowed) 2 copies of plan Cert of Survey Recd _ Y_ N
2 copies of plan showing beam & window sizes; poured found desi n, etc. 1 set of Energy Calculations for heated additions Tree Pres pian Recd, _ Y_ N,
1 set of Energy Calculations 9 1 site survey for additions & decks Tree Pres Required _ Y_ N
3 copies of Tree Preservation Plan ff lot platted after 7/1/93 Addition - indicate Hon-site sepUc system On-site SepGc System Y_ N
Rim Joist Detail Options selection sheet (buildings with 3 or less units)
Date 2( ~ 0(0
Construction Cost 13~
Site Address q4tol, U300D GA'P& (oo('v
Unit/Ste #
Description of Work g)&,g~ nEcA<
Multi-Family Bldg _ y_ N Fireplace(s) _ 0 _ 1 _ 2
Property Owner ae~~ LgT`Z&(O Telephone # ( )
Contractor VS M0JD&-EJL5
Address City ~~0 <~j t~ ~ ~G K
State no
ZiP Telephone # 53 ( • Z,y' 47
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
Fneergy Code Category - Minnesota Rules 7670 Categor~ Minnesota Rules 7672
(44 submission type) • Residential Ventilation Category 1 Worksheet .
Submitted New Energy Code Worksheet
• Energy Envelope Calculations Submitted Submitted
Have you previously constructed a building in Eagan with a similar plan? _ Y _ N If so, 25% plan review
fee ppplies.
Licensed Plumber FF_7 ~ ~ ~ ~
v L~n U ~ Telephone # ( )
Mechanical Contractor it, , 6),Q )nnF I II II
Telephone )
Sewer/Water Contractor Iu~
Telephone # ( )
Inv _ - - ~
I hereby apply for a Residential Building Permit and acknowledge that the information is complete and accurate;
that the work will be in conformance with the ordinances and codes of the City of Eagan and the Sta.te of MN
Statutes; I understand this is not a permit, but only an applicati for a permit, and work is not to start without a
permit; that the work will be in accordance with the approved i c of work which requires a review and
approval of plans.
Cokf 13 m og~
Applicant's Printed Name
Applicant,s Signa e
OFFICE USE ONLY
Sub Types
? 01 Foundation ? 07 05-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg
O 02 SF Dwelling ? 08 06-plex ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ext. Alt - Multi
? 03 01 of _ plex ? 09 07-plex O 17 Garage 0 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt - SF
? 23 Porch (screen/gazebo) ? 36 Multi Misc.
? 04 02-plex ? 10 08-plex ~:K 18 Deck
0 05 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage
O 06 04-plex ? 12 12-plex Plbg Y or _ N 0 25 Miscellaneous
Work Types
/-1 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding
O 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair
? 37 Demolish Building' 0 43 Reroof ? 46 Windows/Doors
? 33 Alteration
? 34 Replacement 'DemollUon (Entlre Bldg) - Glve PCA handout to applicant
Valuation Occupancy MCES System
Census Code ~ L Zoning City Water
SAC Units Stories Booster Pump
# of Units Sq. Ft. PRV
# of Bldgs Length Fire Sprinklered
Type of Const Width
REQUIRED INSPECTIONS
Footings (new bldg) FinaUC.O.
_;k Footings (deck) ~ Final/No C.O.
Footings (addition) Plumbing
Foundation _ HVAC
Drain Tile Other
Roof Ice & Water Final _ Pool _ Ftgs _ Air/Gas Tests Final
Framing _ Siding _ Stucco _ Stone _ Brick
Fireplace _ R.I. _ Air Test _ Final _ Windows
Insulation _ Retaining Wall
Approved By: I L~ , Building Inspector
Base Fee ~
Surcharge
Plan Review C
MC/ES SAC ~ ~ .
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
License Search
Copies
Other
Total
.
r.
l
T TMIE ~ ~ ~i
PLAT DRAWIN~.~
•Fi lTi''Aca 444593r
fl- I3iSP. Datot 0114/04 Gy;
Pfoper'~y Addl'oso; ~~~~~~~E C-OVE, EAGAN
guyar: LO1'ZOW
L+~gal: LOT 1a iB'LOOK 'i, WOODGATE WVF ~
'Ph3e, Pt#t Drowitg f-S) ot 1nlgrlda,d Ro b~ u"d ±44 ik svRV*r ano rh*ald +Ia9 b# r#n#g opgn 4.~ $Wh.
rn. !pt 06mmelons Ire iakon gro(o the nr~~rome,ptat or tho county r~cord; and gr+
!o M ettuKat+t, Th# iooafion of ft !M r~~rser~~~tg showe an thl~ dra+~ino ars l
, epprolu~ttt ar~d see bov~ upeai s vi~ma dnap+r, W ihrf pr#MiSQL A ~~~ome ~
~ oueroYSF 41;jvW b* aont;atoO 11 an aoourtte ruirr#y W dsrirad. Yhis ptat &tw4ng '
dqex not 602411t+W a tlabpl1y oi the eampat+y iorod is odtendorl fat rgo bu 4hm p9mpgny Df#y,
I ~ 4i~ ~
fPYd
Udlly ~
6lasrr4~t9
i '
,
+ ;
i 10
9o° I
. - . „ dgt
. A`*
i
~ J.
F ~r o
C104~
.
. .
~~,x~ . . . - : ~ - = - ~r}:~,;z,...._,.....:.:_. - . . •
-
i
1
i
1
~
f ? ~
~ F-S LEGACY REPORT 93-52.01
G Reissued April 1, 2003
1 C C E v a I ua t i o n S e rv ic e, I11 C. BusinesslRegional Office # 5360 Workman Mili Road, Whittier, California 90601 #(562) 699-0543
Regional Office # 900 Montclair Road, Suite A, Birmingham, Alabama 35213 #(205) 599-9800
WWW.ICC-@S.org Regional Office # 4051 West FlossmoorRoad, Country Club Hills, Illinois 60478 #(708) 799-2305
Legacy report on the BOCAO National Building Code/1999
DIVISION: 06-WOOD AND PLASTICS 2.2 DESIGN LOADS
Section: 06110-Wood Framing
The deck system is designed to bear a maximum live load
DESIGNER DECKS@ of 60 pounds per square foot, a 200 pound concentrated
load in any direction on the railing, a 200 pound concen-
DECK AMERICA, INC. trated horizontal load on the railing infll, and a non-
1041 CANNONS COURT simultaneous 60 pound live load and 300 pound concen-
WOODBRIDGE, VA 22191-1434 trated load on the staircase.
2.3 INSTALLATION
EVALUATION SCOPE The deck system is assembled as a grouping of 4'-0"X4'-
0" modules of prefabricated components which are
Compliance with the following code: mechanically connected in the field.
BOCA Nationa/ Building Code/7999 The deck posts are supported on precast concrete foot-
# Section 2303.1.1 Allowable stress design ings which are installed below grade to the frost line of the
locality or to a minimum depth of 24", whichever depth is
1.0 DESCRIPTION OF EVALUATION greater.
This report is an evaluation of Designer DecksO exterior The mechanically lam'inated girder beams, side bands,
modular wood decking system for use as a structural load and cross joists have notched ends, which are reinforced
carrying floor system. by factory applied truss plates. The notched beam ends
form a wood to wood connection with the mechanically
laminated ledgers of the front band and house plate. The
2.0 DESCRIPTION AND USE OF PRODUCT connections are mechanically fastened with eight 3 inch
galvanized screw shank nails toe nailed into each connect-
2.1 GENERAL ing beam (see Figure 2).
The Deck America Inc., Designer Decks@ are prefabri- The deck system is attached to the adjacent structure by
cated deck systems for installation adjacent to and in means of two rows of galvanized lag screws of 3/8"
conjunction with one and two family dwellings. The system diameter and washers of sufficient length to ensure a
is constructed from No. 1 and Select Structural grade minimum penetration of 1 sia" into the existing 2"x8", 10"
marked Southern Pine. The lumber is pressure treated or 12" wood house plate, brick wall or concrete wall of the
with NatureWoodT"" preservative (NER-628). existing structure. For attachment to brick or concrete
The deck system consists of precast concrete footings, Walls the lag screws are installed into expandable lead
mechanically laminated deck posts, laminated girder anchors inserted in predrilled holes having the same
beams, cross joists, front bands, side bands and house diameter as the anchor.
plate, and 4'-0"X4'-0" decking modules (see Figure 1). The upper row of lag screws are spaced at 24" on center
The system also consists of prefabricated railings and maximum and extend through the deck house plate into
prefabricated stairways. All components are assembled the existing strudure. The lower row of lag screws are
using hot-dipped, zinc coated galvanized screw shank
nails, truss plates and lag screws. spaced at 48" on center maximum and extend through the
deck ledger and house plate into the existing structure.
The decks are available in standard sizes, in increments of
4'-0". In the case of decks with an overall width not in 4'-0" The deck railing assembly is attached to the deck perime-
increments, the required width is accomplished by prefabri- ter by means of galvanized lag screws and washers
cating either one or both of the outside modules to a installed through the deck railing posts, which are spaced
dimension of less than 4'-0". The maximum height of at 48" on center maximum, and penetrating the perimeter
installation shall be 14'-0" above grade, measured to the band members.
finished deck surface. The deck posts are spaced in The manufacturer shall supply written instruction to
maximum increments of 8'-0" on center parallel to the provide for the proper and safe installation of the deck
building and 12'-0" on center perpendicular to the building: system.
l('('-li,Cle,Cic_N lcpurl.cqrr nn!!n be cnqe'Irued n.creju'e.reqling net[haliee nr nny adicr nltriGWC.a nol speci,Jicu!ly addre.vred, qar nrclher ln he cuaclrueJns nn un?nr.ceiueiN a/'I/ru %uhjecl
u/'ihr repnri nr u rnrmuroeodaiiun for ii.c uce Tlrere i.s nn unirrnnin hv lC(' F.rnhmlion .eenicv, bic., expre.cs or implied, as io an.v jmJiiig nr nihar moNer m ihi.s repuri, or 7.1 io mp,
prudur! ru rrrrd hr 1hr rrpw t.
CopynghtOO 2003
. PEigii 2 of 3
- 93-52.01
, 3.0 CONDITIONS OF USE 3.7 The elevation of the Designer DecksO system stair-
This report is limited to the applications and products as case is limited to 10'-0" maximum. Decks having an
stated in this report. The ICC-ES Subcommittee on elevation greater than 10'-0" shall have an intermedi-
National Codes intends that the report be used by the ate landing between stair runs.
code official to determine that the report subject complies 3.8 5eismic analysis of this system is outside the scope
with the code requirements specifically addressed, pro- of this report.
vided that this product is installed in accordance with the
following conditions: 3.9 This report is subject to periodic re-examination. For
information on the current status of this report, con-
3.1 Designer DecksO shall be installed in accordance tact the ICC-ES.
with the manufacturer's written instructions and with
the requirements stated in Section 2.0 of this report. 4.0 INFORMATION SUBMITTED
3.2 Construction documents, including design calcula-
tions shall be provided with permit applications. The The system has been reviewed for its ability to withstand
individual preparing such documents shall be compe- applicable live, concentrated, and snow loads based on
tent and qualified in the application of the structural structural calculations and detail drawings submitted by
design principles involved, and shall possess the the applicant. The system has been designed in accor-
registration or license in accordance with the profes- dance with the requirements of NFoPA NDS and NDS
sional registration laws of the state in which the Supplement, 1997 Edition.
project is constructed.
3.3 Lumber used in the construction of Designer DecksO 5.0 INFORMATION REQUIRED ON CONSTRUCTION
shall bear the grade mark of No. 1 Southern Pine for DOCUMENTS
all framing members, and deck members except for To aid in the use of this report the following represents the
the following: minimum level of information to be reflected on construc-
• 2"x 10" girder beams with laminated 2"X4" ledgers tion documents in order to determine compliance with this
spanning 12'-0" research report.
• 2"X 10" front band with laminated 2"x4" ledgers 5.1 The language "See ICC-ES Legacy Report No. 93-52."
spanning 12'-0" 5.2 Indicate the minimum allowable soil bearing pressure
Which shall bear the grade mark of Setect Struc- for the deck system footings, and the required size of
tural Southern Pine or better by an approved footings.
agency. 5.3 Indicate height of deck above grade.
3.4 All lumber used in the construction of Designer 5.4 Indicate minimum depth of footings below grade and
DecksO shall be pressure treated with preservatives local frost line.
conforming to the requirements ofAWPA C1-92, C2-
92 and C9-90 and AWPA P1/P13-91, P2-90, P5-92, 5.5 Indicate lumber size, species and grading for all
P8-91 and 139-92. Preservative treated lumber shall members.
bear the quality control mark of an approved agency.
3.5 Other than cutting to allow for fabrication of a deck 6.0 IDENTIFICATION
module with a dimension less than 4'-0", as indicated Deck America Inc./Designer DecksO manufactured in
in Section 2.1 of this report, no field cutting, alteration accordance with this research report shall be marked at
or notching of structural members is permitted. the plant with the identifying language, "See ICC-ES
3.6 Review of concrete footings for the Designer DecksO Legacy Report No. 93-52."
system is outside the scope of this report. Calcula- This report is subject to re-examination in two years.
tions signed and sealed by a registered design
professional shall be provided to the code official to
substantiate the design of the footings and to sub-
stantiate adequate size such that the allowable soil
bearing pressures are not exceeded.
I
~ ?
` Page 3 of 3
93-52.01
10 .9
1. Decking module: 4'x4' size l~ 8
i
2. Front band: 2"X10" with laminated 2"X4" 11 ; ~
ledger (16' maximum)
3. Precast concrete footings
4. Post: 3 laminated 2"X4" or 2"X6" members ~ i
5. Side band: 2"x10" with laminated 211x4"
ledger (16' maximum)
. I
6. Wind brace: 1"x4" diagonal ~
7. Girder beam: 2"x10" with laminated 2"X4" ~
ledger on both sides (16' maximum) ~ j s
8. House plate: 211x10" (16' maximum) ~
9. Ledger:2"x4" 2 ; 5
10. 20 gage galvanized truss plate (2"x8")
11. Crossjoist: 2"x10" with laminated 2"x4"
ledger on both sides (typical - 4') 4
3
Figure 1* ~
TYPICAL 8' x g'
DESIGNER DECKSO SECTION
rxroKVANZED
20Wae TMea ru?tsa
aN~xooeso~wanw ~
Aro uwMtso aMOO wwa,
aot awM atc~o~s~o~ts ~
rx~a wo?ea~
ai~e+u:
rxW Leoc+ER
.
1wo r aKVAmm
• ~tanra~wacw?ns
zWLeuM
\ ~ •
rxir
1/WMA7LD Oli IA FORY A
fll0llT WO ~ 1M1117i! 27h1' lfDOllld OF
CONMWT*p NEAN18. aart r
aALVANMaataaSWJrc
~ TOCa Ea'Mna ~
'MO?E 7lNT 6= RIYOS ANO
CROis MlTS REW"ONE rAP LupER
?X4' 1A11NI1TED IEDOEIt A!a
TlYIT QIROElt KAM REOIM 1YI10.
Figure 2*
"THESE DRAWINGS ARE FOR ILLUSTRATION PURPOSES ONLY. THEY ARE NOT INTENDED FOR USE AS
CONSTRUCTION DOCUMENTS FOR THE PURPOSE OF DESIGN, FABRICATION OR ERECTION.
Mar 13 12 03:10p Jarod Olson
2 Pal -es Totim&-
Citi of EaQall "ij
3830 Pilot Knob Road
Eagan MN 55122
Phone: (651) 675-5685
Fax: (651) 675-5694
Email:
hi -
6516318661 p.1
For Office Use
% (�
Permit*: /t / -o
Date Received.
2012 ZONING PERMIT APPLICATION
✓ Please submit a set of scaled drawings with the application. ° 5C.Fk-P i iL oWe,IaW,C0
PROPERTY
CONTACT
TYPE OF
WORK
PLANNING
Approved:
Notes:
Revised Plans
Approved:
ENGINEERING
Approved:
Notes:
Revised Plans
Approved:
COMMENTS
Site Address:
Name:
Address:
�d 2 14-c1 _t6vt✓
AWN Phone: (76i.5,) 757-9t/Q6
City/State/Zip: POSe(A le "lo 5 S113
— —Date: 04 /3 2ai 7--
0 Driveway ❑ Other:
Applicant Signatu
Retaining Wall
❑ Patio
❑ Sidewalk
0 Sport Court
0 Fence
Description of work: Bo 18,d Ith Li I4 10 /4 . X2
Awa ll5 aLduf 3 h ill.,,' 3' et- a i -
!j'3 is/l a(Lou i- /5' . house_
Setbacks, hard surface coverage, shoreland zoning, bluff zone/setbacks, etc.
No Date of Approval: /20 /
C<c .t2cY
Staff: ,Ry,
LY1
Yes / No Date of Approval: Staff:
Grading, drainage, utility easements, wetlands, erosion control, improvements in the Right -of -Way, etc.
Yes / No Date of Approval: Staff:
Yes / No Date of Approval: Staff:
G:\Building Inspections\PERMIT APPLICATION/S1201 f\2011 Permit Applications
Mar 13 12 03:10p Jarod Olson
e
.0 0
6516318661 p.2
Certificate of House Location For:
Equal; Access Homes
DELMAR H. SCHWANZ
' LAND SURVEYORS. INC.
Registered Under Laws of The Stale of Minnesota
14750 SOUTH ROBERT TRAIL ROSEMOUNT. MINNESOTA 55068
SURVEYOR'S CERTIFICATE
Address: 4402 Woodgate Cove
= Found iron pipe monument
= Set wood hub at building offset
= Existing spot elevation
= Proposed elevation
= Proposed direction of drainage
Lot Area = 11,546 square feet
House & Garage Area = 1,236 square feet
Service Invert Elev. = 927.3 :it
936.5 S89'44'4i"W 9
�' E AND UTILITY E
937.1
sit T
f'P a
/0 --5'6/Q
H03039/449,
toctocioA4c
Co
651/423-1769
SCALE: 1 INCH = 30 FEET
House Type: Tuck Under
930.9 930.2
9A2.9
}
1r(1 c..t,,I V1,1 f,l�. t4ek 1 11
3
1• 948.5
4A
tD44
1932.
943,1
>`tp• Esc n P%.3i 47. w'rs 947.5
00
.3 -A
e03
N0 942.7
Cl
•
.";�8 10. •,;
934.1
940.6
934.6,
938.1
A10.08'00°
Lm7.96
Rw45.00
Property Description:
Lot 1, Block 1L WOODGATE COVE, according to the
recorded plat Itlhereof, Dakota County, Minnesota.
I IIAlso showing the location of a proposed
house staked thereon.
.7
6
,p,1461'
\100°'''
I hereby certify that this survey, plan. or report was .'• .,•1)
prepared by me or under my direct supervision and
that I am a duly Registered Land Surveyor under
the laws of the State of Minnesota.
Dated April 11, 2003
Proposed garage floor elev. (7-`w':4s�
Proposed top of block elev. 944.
Proposed to est level elev.
DELMAR H. *4
SCHWANZ //41,
s ° — 8625 &Delmar H. Schwanz
VI? 'Minnesota Registration No. 8625
PERMIT
City of Eagan Permit Type:Building
Permit Number:EA114535
Date Issued:09/17/2013
Permit Category:ePermit
Site Address: 4402 Woodgate Cove
Lot:000 Block: 000 Addition: Woodgate Cove
PID:10-84650-01-010
Use:
Description:
Sub Type:Reroof & Siding
Work Type:Replace
Description:
Census Code:434 -
Zoning:
Square Feet:0
Occupancy:
Construction Type:
Comments:If there is no ice protection inspection prior to final, the contractor must meet the inspector w/ a ladder and flat bar.
Pictures are not acceptable in lieu of inspections.
When installing ventilated soffit material, remove existing material (i.e. debris that could block vents) and take steps to
ensure maximum ventilation to attic. Call for final inspection after installation.
Valuation: 8,000.00
Fee Summary:BL - Base Fee $8K $162.25 0801.4085
Surcharge - Based on Valuation $8K $4.00 9001.2195
$166.25 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Christophe R Lotzow
4402 Woodgate Cove
Eagan MN 55121
Sela Roofing Remodeling
4100 Excelsior Blvd
St. Louis Park MN 55416
(612) 823-8046
Applicant/Permitee: Signature Issued By: Signature
PERMIT
City of Eagan Permit Type:Building
Permit Number:EA114864
Date Issued:09/19/2013
Permit Category:ePermit
Site Address: 4402 Woodgate Cove
Lot:000 Block: 000 Addition: Woodgate Cove
PID:10-84650-01-010
Use:
Description:
Sub Type:Windows/Doors
Work Type:Replace
Description:Two or More Windows/Doors
Census Code:434 -
Zoning:
Square Feet:0
Occupancy:
Construction Type:
Comments:Improvements to the home require smoke detectors in all bedrooms. If altering window openings, call for framing
inspection. Call for final inspection after installation.
Carbon monoxide detectors are required by law in ALL single family homes .
Valuation: 4,000.00
Fee Summary:BL - Base Fee $4K $103.25 0801.4085
Surcharge - Based on Valuation $4K $2.00 9001.2195
$105.25 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Christophe R Lotzow
4402 Woodgate Cove
Eagan MN 55121
(651) 493-0088
American Exteriors Of Minnesota Llc
1408 Northland Drive #106
Mendota Heights MN 55120
(303) 865-3328
Applicant/Permitee: Signature Issued By: Signature