Loading...
4892 Twins Ct PII&NEER engineering CIVII. ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITEGTS ~ 2422 Fnterprise Drive, Mendota Heights, MN 55120, (651) 681 1914 Fax:681 9488 - Pioneefeng.com Certificate of Survey for: BRANDL ANDERSON HOMES ADDRESS: 4892 AND 4896 TWINS COURT, EAGAN, MN ~ COMBINED LOT AREA LOTS 17 AND 18 MODEL: LONDON/RIVIERA ~ LOT AREAS =18,118 SQ FT ~ - ~ BUILDING AREA =3,690 SQ FT ~ O D' D PORCH AREAS =170 SQ FT COVERAGE =21.3% / i HOUSE TYPE: FULL BASEMENT _mO ~ - m ~'1~-~"L / g 9~pQQ~a'= j J~ 1~896 3:9 AAaci 9zn Sla~ / R,~,~.~6/~PN~ - ~ 41.28 N~ 93a.~ ~ or Re4ainin NVall VUiIC Be Required 939.3 ~ 22.31 M 93. 40.2 39Xv ~ / N LO ~h~'~/~ ~ BEN~f IN RMK:~ I 3 940.0 _ TOP OF SPIKE 1$ ELEV.=940.67 *941.2 ~ F J J`. A~940.7 ~a . z w y 5 e7 0 940.41aa . / ~ / ~ ~ ? 947.6 941.6 I I x (Wj W ~ W ' I ~ v< N . ' . 940. i/ 35.33 o m ~ va vu"i 00 Z n Of a O \ ~ \ "0 ~ IK A p W ~ F941.4 ~ TI ~~W 0 ; / . / O I N ~ 1.8 1.7 I 11 0 Q \ i J'\ sai.o ~i ' 4' sai. 12.00 ? Z < 941.7 i _s.ss. 0, ~ ~ \ \ W 41.1 94 X v ~ D " /o o° lS. ~ p I_ m 7T 91~ff ~a rM Oo o /D Q ~.Q.yI~ f~ S O~P~L\-V as ~°o ~ ° m o U n ° 5.00 _ ~/"1 3 3~i E~ 134.83 943.4 m N87'4 ' I .942.2 cp.~j~ 2y\ sai. 942.2 60.3X I v oi m/ O1 N ~ ~N(T W. ~ - \ ov c' i a nz tD D 1 C N ~ m v ~I o . OtT \ c ^9 c ~ So ~ o n L/C0•/o o d- i Q J\\ 1 jin pp A G~ l TI Z A K,,~ I v U'J ~ i ~ ~m I D ~ g g 91.8 I 117v ~ W_ / . v 942.4 ' 8.73' Ot / 12.00 N__ ~ 37.7 4 30.5 eai 4 1 i/ J f J 1 ' ~ i tp 0 l y.8 0 x 942a 942.3 I 00 t i N~' LA o, F ~ I N w 35.33 n N ~ ° 1 ~ I 0 ~ o0 10 ~ r--- ..a, 942.} 9~2.1 C ~ ~y-4~~-- O~ V) o ` I ~ r ~ 9 - - _ 124 9 aza C ~1 N ~ 946.9 29.23(943.4) 943.6 6~.38 (944.0) 943.9 .3 ~ 94. 94.8 ~ p/i, _ 9 crv ~ (943.3) °o zs ' 'S1'32"W 125.66 P~OdDE AND I~AINTAIN z eeNCH MARK: ; INLE1 PROTECT ON UIVTIL 5 IKE ' n .0 - TOP OF SP R. .w. ~ EIEV.=943.60 FINAL TURF IS E TABLISHED I v (VACANT) Iv v I 8 8 30.0 SEWER SERVICE INVERT ELEVATION LOT 17 = 933.3 PLAN BENCH MARK: TOP NUT HYDRANT, LOT 14 AND 15, SEWER SERVICE INVERT ELEVATION LOT 18 = 932.5 PLAN BLOCK 1, HOMESTEAD VILLAGE ELEV.=949.33 HOUSE ELEVATIONS :(PROPOSED) /ASBUILT NOTE: ADO BPoCK LEpGE AS REOUWED ~ NOTE: GRADING PLJJ/ BY PIONEER LAST DA7E0 fl/B/OS WAS USED LOWEST FLOOR ELEVATION .9~37.5) I TO OETEfiMWE THE PROPOSED ELEVAPONS SHOWN ON RIIS CER71FlCAlE. ~TOP OF FOUNDAl10N ELEV. ~ 945.2 NOTE: PROPOSED BUILOINC OIY61510N5 SNOWN ARE FOR MORIZONTAL IOCAT10N OF $iRUCN0.E5 ON 7HE lAT ONLY. CAN7ACT BURDER GARAGE SLAB ELEV. 0 DOOR : 944.8 PRIOft TO CWJSTRUCTION FOR APPROVEU CONSTHUCTION PUNA p NO7E: NO SPEqFIC 5(MLS INVESi1CAT10N HAS BEEN PERFORNED ON MIS LOT ~pB lis(Irl Y THE SURVEYIXV. THE SUITABIUTY OF SOILS TO SUPPONT THE SPECIFlC HOUSE PROPOSED IS NOT THE RESPON98NTY OF i11E AIRVEYOft. D$LC SO~( (lO _ X 000.00 Da0iE5 EbSTNG ELEVAPON NOTE: TNIS CERMCAIE OOES N0T PURPdiT TO SHOW EASENENT$ OTHER ,~p~ ~~~pI~~ ) DD10TE5 PROPOSED Fl£VATON TlIAN IHOSE SNOYM ON THE RECOROED PIAT. ~Qryv F.~VGYaGLiaw~G U}SY~T. o~0TE5 DRAINAGE AND UlIL1TY EASENENT ~ OENOTES DRAINAGE F10W DIRECl10N NOTE: CONTRACTOF NUST KJUGY DRIVEWAY DE9GN. A- OENOlES SPIKE NOiE: BEARWGS $NOYM ARE BASED ON AN ASSUMEO DAIUM OENOTES ElEVA710N ON WE HEREBY CERTIFY TO BRANDL ANDERSON HOMES THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A (xxx.x) 06lOTES ENENCENCY OVERFIOW E.O.F SURVEY OF THE BOUNDARIES OF: LOTS 17 AND 18, BLOCK 1, HOMESTEAD VILLAGE DAKOTA COUNTY, MINNESOTA IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS. EXCEPT AS SHOWN. AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 7TH DAY OF APRIL, 2008. a-a-oe STAKED HWSE SIGNED: I ER ENGINEERING, P.A. SCALE : 1 INCH = 20 FEET eY: Q~, 3606 105255004 MTW NJK Peter J. ' awkinson Licensa No. 42299 , . . , "7b~T/. ~ I Clty Of EapIl PL ~ 7 '?o . s0 ; Parm;, # C ~ 3( permit Fee: ~ 3830 Pilot Knob Road ~ Eagan MN 55122 ~ Date Received:OC~o Ck5 Phone: ~ Fax: (651) 675-5694 1 Staff: ~ 5 75 I - _ j_11 ~ ' 2008 RESIDENTIAL BUILDING PERMIT APPLICATION L- fJ II~~~ ) ~~1~F Date: S~~~O~~_SiteAddress:48`Ia ~ r,~, n5 ~ou?~ L1~Ig ~lOC,, I bGl4 -i//9/I°1 Tenant: ko(n Fsyt~-}(~ IA-G~ Suite RESIDENT / OWNER Name: 3 rrA'"R r a,-N 5 Phone: f 52 "T`l 5l'OZ- 3 O Address / City / Zip: Se" BP ~ow Applicant is: _ Owner X Contractor TYPE OF WORK Description of work: NO w Fc. wi i) V Hvme ne Construction Cost: Lprox. ~a060Ct~;•~ Multi-Family Building: (Yes No _X_j CONTRACTOR Name:I;^:.,n,A( A-Y)c{e.~,'s,_,--r\ ~jrnP S License#: Address: `~~S S E r i n I?'~' Ciry: E44 Gtit state: i''1.() zip: j,;2 Phone: j 5~; -Sf`JSI- 02 30 Contact Person: (4rnGne6L wheE COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING Minnesota Rules 7670 Cateaorv 1 ~ Minnesota Rules 7672 Energy Code . Residential Ventilation Category 1 Worksheet • New Energy Code Worksheet Category Submitted Submitted (-J Submission type) • Energy Envelope Calculahons Submitted In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes X-No If yes, date and address of master plan: Licensed Plumber: 10 ly mn,~ ~ m Phone: 7~3'yJZ- E/d~5 Mechanical Contrector. q i Mu.~fe; s IOC . Phone: T52 ' ~3 I - 573 ~ Sewer & Water Contractor: N{ ~ n v1f,5c ; r 'F W='l 1'1 Phone: ~/11 -7 I4- 3 I5 F °NOTE;yRlans-and supportiirg`docuinenis-that;you.submft are;considered fo be publi0nforrriation. Portinns of "`ihe infoirnation~may<befcla'ssified as=non-putilicilyou~provlde specific reasonszth'at would permit the;City to conclutle°tiiatYhe are;trade secrefs. I hereby acknowledge that this information is complete and accurate, that the work will be in confortnance with the ordinances antl codes of the City of Eagan; that I untlerstand this is not a permit, but only an application for a permit and work is not to start without a permit; that ihe work will be in accortlance with thne approved plan in the case of work which requires a review and approval oYplans. x p-rn an d.ri kVh,?r lE x ApplicanYS Printed Name /A p icanYS Signature Page 1 of 3 DO NOT WRITE BELOW THIS LINE • SUB TYPES ? Foundation ? OS-plex ? 16-plex ? Accessory Building ? Pool ? Single Family ? 06-plex ? Fireplace ? Porch (3-season) ? Ext. Alt. - Multi 01 ot --~,Plex ? 07-plex ? Garage ? Porch (4-season) ? Ext. Alt. - SF ? 02-Plex ? 08-plex ? Deck ? Porch (screen/gazebo/pergola) ? Multi Misc. ? 03-Plex ? 10-plex ? Lower Level ? Storm Damage ? 04-Plex ? 12-plex ? Miscellaneous WORK TYPES New ? Interior Improvement ? Siding ? Demolish Building' ? Addition ? Move Building ? Reroof ? Demolish Interior ? Alteration ? Fire Repair ? Windows ? Demolish Foundation ? Replacement ? Egress Window ? Water Damage ' Demolition (entire building) - give PCA handout to applicani DESCRIPTION: Valuation ~010 Occupancy AL.~( MCES System Plan Review Code Edition 2t(2(9~ SAC Units (25%_ 100%_xj Zoning City Water Census Code ( ~71 Stories _L Booster Pump # of Units Square Feet I PRV ~ r~(1j # of Buildings Length ~ Fire Sprinklers Type of Const. VG_ Width REQUIRED INSPECTIONS Footings (new bldg) ~ Sheetrock ~ Footings (deck) ~ Final/C.O. Footings (addition) Final/NO C.O. ~ Foundation HVAC Drein Tile Other: Roof: Ice & Water _Final Pool: _Footings _Air/Gas Tests _Final Framing Siding: _Stucco Lath ~CStone Lath Brick ~ Fireplace:--R.l. ~Air Test Final Windows ~ Insulation _ Retaining Wall Reviewed By: Building Inspector - - -------------------n - RES/DENT/AL FEES: Base Fee I C~ 1 Surcharge Plan Review ~ MC/ESSAC ~•v 1V uY' 7' ~ity SAC ~q Utility Connection Charge ~ S&W Permit & Surcharge ~ u )u % Treatment Plant Copies OJU Total Paqe 2 of 3 • - ~ a's,sy Permit # Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: London Spec - Flat Lot Report Date: 05l06/08 Data filename: C:\Program Files\Check\REScheck\4892 Twins.rck Energy Code, 2000 Minnesota Energy Code Location: Dakota County, Minnesota Construction Type: Single Family Glazing Area Percentage: 12% Construction Site: OwnedAgent: DesignedContractor: 4892 Twins Court Amanda Wheeler Eagan, MN 585123 Brandl Anderson Homes 4555 Erin Drive N120 Eagan, MN 55122 952-898-0230 awheeler@brandianderson.com e..• Ceiling 1: Raised or Energy Truss: 1422 44.0 00 31 Wall 1: Wood Frame, 16' o.c.: 2277 19.0 5.0 97 Window 1: Above-Grade:Vinyl Frame:Double Pane with Low-E: 262 0.350 92 Front Door: Solid: 20 0.400 8 Garage / House Door: Solid: 78 0.110 2 Basement Wall 1: Solid Concrete or Masonry: 1044 0.0 5.0 86 Window 2: Basement > 5.6 i12:Vinyl Frame:DOUble Pane with 19 0 350 7 Low-E: Floor 1: All-WOOd JoisViruss:Over Unconditioned Space: 8 30.0 0.0 0 Fumace 1: Forcetl Hot Air: 90 AFUE Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit appliration. The proposed building has been designed to meet the 2000 Minnesota Energy Code requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. / y ~Builder/Designer ~ Company Name Date London Spec - Flat Lot Page 1 of 1 LOT SURVEY CHECKLJST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: 4 S~ I£ I~ ~IO1' IC I n'~~ ~IIIaJ DATE OF SURVEY: ~II 7I~~i IATEST REVISION: d tm c R t U Q ~ p Z Q DOCUMENT STANDARDS 0 • Registered Land Surveyor signature and company ~ ? ? • Building Pertnit Applicant ~ ? ? . Legal description ~ ? ? . Address ,r ? ? • North arrow and scale '.7 • House type (rambler, walkout, split w/o, split entry, lookout, etc.) '2 ? ? . Directional dreinage-arrows with slope/gradient % ,0 0 0 • Proposed/existing sewer and water services & inveA elevation ? 0 • SVeet name fd - 0 ? • Driveway (grade & width - in RIW and back of curb, 22' max.) ? ? . Lot Square Footage ? ? • Lot Coverage ELEVATIONS Existin ? 0 • Property wmers p? • Top of curb at the driveway and property line eutensions ~A p • Elevations of any existing adjacent homes • Adequate footing depth of structures due to adjacent utility trenches ,9 ? ? . Watenvays (pond, stream, etc.) Prooosed ? ? . Garege floor ~ ? ? • Basement floor ,g p ? • Lowest ezposed elevation (walkouUwindow) p p ? . Property comers )z • Front and rear of home at the foundation PONDING AREA (if applicable) ? ~ 0 • Easement line 0 ~ ? . NWL ? ~ ? . HWL . ? ~ ? . Pond # designation ? ig 0 • Emergency Overflow Elevation ? ,PJ 0 • Pond/We[land buffer delineation Y . Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS ,I~ ? ? • Lot lines/Bearings & dimensions • Right-of-way and street width (to back of curb) ? O • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all struc[ures requiring permanent footings) Z 0? • Show all easements of record and any City utilities within those easements ,Z 0? • Setbacks of proposed structure and s ey rd setback of adjacent existing strudures ,Q • Retaining wall requirements: / I ~ i Reviewed By: - Date G:/FORMSlBuilding Pertnit Application Rev. 11-26-04 Page 1 of 1 Connie Edwards From: Betsie Mills [bmills@brandlanderson.com] Sent: Friday, November 07, 2008 10:34 AM To: Connie Edwards Cc: Carol@pearsonplumbing.com Subject:~489 a2 nd 48964twins-court'Permits 83137 and 83131 Connie, These jobs have been reassigned to Pearson Plumbing Corporation Phone (320) 963-1010 Plymouth Plumbing no longer exists they have merged with Wenzel and become Wenzel - Plymouth Plumbing, LLC Do you need any additional information Thank You, -/.l%e :w Brandl Anderson Homes 4555 Erin Drive Eagan, MN 55122 952-898-0230 ex 215 bmills brandlanderson com ll /7/2008 Job Name: BRANDL TWIN Truss ID: P2 Qty: 10 JID: 376877 0NC %-LOC 0.EAR SIIE 0.Ep'D TC 2x4 SPF C3650F1.SE Neb bracVry re4u1nE at uch lontlon shwm. TMs Mz1pn bazeC on chorE braclnp e0D11ad 1 0- 3-11 3397 5.50" 3.OP 2a1 SVF Q100i1.8E 1-3 ~ See cUnEard Een11s (TX01oe)001-001 revl), pr eM follulnq sch4EuL: Z 39- 3- / II13 5.50" 3.41" 2z6 SVF C1650F1.5E 6-I •[PMj.pUTE MpNIIOR OSFD-Se. ]otni Reporc^ maa O.C. tran m BRG REQUIRENEHfS shwm arv basaE WLY g~ 2y1 SPF N1/Y2-GVI ~esipn.d per MSI/!PI 1-2003 TC 34,00" 23- 0- 0 30- 0- 0 on iha vuis meterlal si each bearln9 Ix4 SVF C2100F1.8E !-SO Thlz Eastpn Eoes no< attount for lmY ttm UVLIR 0.fARI0N(5) : Brp 0.eacC UDHft Re9~4 51za wg 2x1 SPF #lp]-GN ttm~ EepenEent loWinp (cnep). Butldtnp Supporc Ma1n N1nE Non-X1nd 1 2391 -159 3.Oa" 2X3 SVF X3-GN 2-9 4-11 Deslqn~r must ucouni }or M15. 1 -159 16 3 21fl -126 3A3" 2v4 SVF I3-GN 15-~ 0.~fer 20 )olnc aC Mia11 She*t Por 1 -llfi lb XEDLE 2x6 SPF C1650F1.5E Mavlmum 0.onctonal Tolarenn vuC X/0-Drop : 04-12 Luober vhear allorrables an Wir NDS. TXIS DESIO! IS THE COMPoSRE RESULT OF TMs irvsv 1z Ges1GneE uslnp Che INC/I!C iruss D1n<e values an baseC an MOLTIPLE LOAp GSES. ASCE]-OS MinE Spectflqiion uR1np anE approval ae nqWreE by IBC 3103 IF 14WGE0.5 A0.E tNOIUTFD W TXIS OMWINL, B1Eq EncloSeG • Yes, Lnportanu iaccor - 1.00 ps and ANSIRiI mE en nporttd tn availebl• TMEV ARE BASfD IXI 1.5" IiWLER NAILS FOR Truzs toraHpp . Not End 2on. n Bld L~-0E30 ao-10o(lNE)T.C O1M D alna0e~mustENFpov1EN~[oravoeECponElnO. INMGERS MUST2BE CUEVA~LWTEDR(BYS~MERS). Fkan 'rao/ he10htW.~13 860f=0 xXPhih :~r~.0o Ti cLnuL x9spER w¢[s: EnE vertluls are Eu1pneE Tor utal loaEa ASCE] IZ SunEarE Occupanry Wad LmE - 33.0 ps} ic [M. p10.. / ipi. <SI only unless noCeE OthemlcY. D~s1p0e0 az Mi1n M1114 Foft! ~Iss1SL10 $y52Mn 1-x anr :u so o.e4 Exnmlans abev. or Mlw. cM ttuss proflb - Lar-rtse anE CnmOOn~n[s ,ne asee~np i.3 au3 t.Is / nf :w o.se 34 -3369 115 / 39 .60 0.99 Uf any) hav. been e..Iqh.e ror io,e: Tr1bYtflfy Afei . 18 iq}t 1 ~5 -DH 1.15 / 3~l .60 OJi iomc.na oniy. x~.i:onc.i io,as ipy111d IIC 5~6 -i6R 1.~5 / t]~ .6Y 0.96 CM M~ 0} LII! ~[ApHonf I1iW pOS lae0 sa -uv i.is i iu .ca 0 65 ronsid.r*7 unless shown. A Erop-l0p to +n REVAIR- x cair. m~, / m+z. csi otherntu unsuporntl ra11 may creau a THE T.C. IS BROKEN 7-0-0 TO THE RIGMT OF ]OINT I5. I-9 -3N L / vu i.+s a,~e Mnpe tttett x~iu requves aeainonet eeelpn ALL PLATES, UNLE55 OTHERl~25E NOTED, f-io -en t.w / ino u o.w consldoratton (by athers). lo-u -:a t.so /:no :ts o.n MUST BE INTAR AND PkE55E0 IN THE u-ix -ia i.co 0.16 W000 PER TPI. 13-U -113 1.60 / 1399 .IS OJl Il~l~ -lf3 1,60 / 1399 .IS 0.5 uas -n i.~ i ne .so o.u! ~ 22-0-0 ~ 8-0-0 f 98-0 ~ • AOEQUATELV SUPPoRT THE TRUSS we cwv. ou~. csr 1 1 3 4 5 6 7 UNTIL TNE REGAIR IS COMPIETE. i-s -4ro n.~ / m t.bo o,a~ ~ ATfACH THE SU8(S) RS SPEQFIED b9 -'3 1.60 / sw ias o.n ~g"~J- 1-0M/lOd ON EA[H SIDE OF THE BREAK. i.as / ur .w a.ro 20.100 sai -si n.so / ux i.~s a.n 10.10C • PoSITION TME SG8 AS SMOWN. -so> >.as / w i.ao aaf -10 ~ DISTRIBUTE TME NAILS EVENLV. t-a: -a i,w i ~m es a.:o 6-14 -12 w ~.is i vo ~.eo o.n 5X7 6X8 2X4X8'q1/#2SCA0 iis ai,s s i:3o o:9e ~ 3X4 ONE FACE I ~ „/q V S4X6 5X8 11'B-6 12 15 1 5X13 SHIP 6 8X8 Z 086 3X4 5=4X6 4X4 EK6 374 B1 5X5 S-04 g2 l/ W.SOB W.50B R2397 R2773 U: 159 U:-126 1 IIf:NEBN' Cf:N'1'IF'\"1'l1A f'1'i115 PIAIV. $I'F_. ~ 39~ CIFICATION.OR REPONT WA5 PREPAREO ~8 9 1011 1213 14 15~ BYMfONUNDERM\'OIRECfS1:PERV1510\ ANO TIIA f 1 MI A IIC1.1 Nt:C15TF.Rf:11 PNO- FESSIO;VAL ENGIPEER U]DER TIIE L1N'S OFTIIESI' OrIS S TA. C. E. ALTER MICOTieCWIplab, ie TrvMY20 OLOrWM0001, UlIIMpWMCO'XC(dN02O C. •SNrl81s OnROmMDIM• IMfE NI:CISI'NAI'10]\0.13966 TRUSPLUS 6.0 VER: 76.5.7 ~onewwer'rx'torrv.rxmp~.>°H°rm~epanamr~u~.aw~uoi.awrJamB.~vixroonwarawoirn.ndf.~.. 7~22~2~0$ rrem0 oieew a. napaon.a a srorn mo.. m+n aw• aua oi*n 10 naa o~.n~ atn mvetuti niw. la a~oI.l. 147 - A. B. G Mo~~tN~ se WARNINGRead all notes on thla s6ea1 and gNe a copy o/It to the Erecd~ Conbaetw. Cust: LYIMN LUMBER / CHAN. ~ msa.qinra.inawirwanpemaou.tinawwM.m.ni..e«newmy.nm..o~wwWn.wmwwnAn.r.an, W0: OHvaL_S_c8 2 9 7 21000 0 5,00001 .iaawnswenn.an.e.msmen.sm.w~rvnawp.e.naua. wNaWwemyi.u.m.aro,mnmewinwr.ey. om.mem Ds9nr: ]LH MLC = 34 Hf: 2530 ~.ienv~m~aMm.~emW~~„mm?~nu~r~rcmreunMaeO~rM>~eneissen m.euurqar4wmmenNmm~uYbw TRUSWAL ~~~mdr.y~a..i.a...ane.momro~aeywmiau~yma.mem.o.wu..e~.mn.m.a.~...nnwiwwmua 7C L{w 35.00 psf OurFacs L=1.15 P-1.15 swreryenaaqn.mwwmerwenip~~pin.emom~nwabw.nM~~req.nymw.uimpmn.miwrryw.e.a.u~ramwm~x TC Deatl 10.00 Psf aep 4Wr Bnd 1.10 wa.er~n~one.m~.vm~ewewns~emna.mm~me.nelNm~~wenMiw+P~ ttacao~nwanae.o~.ai~.y SYSTEMS """°"°"~wainmm..wu..w.r~erovwmeerwavsuwmnwem~«~n>w..a~em~ r.en.+.,nma,um.~ eC Live 0.00 psf Aep Ibr CaoO 1.10 ~ .we.onnwun.ewwrc.wmm.rmewrowmre.:~~an..acwnuamn.owcrw.na~nmmmv.l.an.... Re0 Mbr Tens 1.10 /)EI?BUllainptamponmts uauwft. uevmr.wrur-warmn<wwarsm.s.aenno.pnw.onwm.xuowocowONErvrwernrowuna+- BC Dead 10.00 psf O.C.Spacinp 2- 0- 0 wsrem~y.ee.sr~n,uev.~p.,w~am~ necyt.wlnaees~w~eYwicAmammenuunig.iwu.lnpne.+oanm>norcmeprn,wmen. De51gn Spec IRC-2006 vncmmune m.As.rc.nrm1wMwatoe.m~~Wn~~nimaa~+~+++emca.w.rFV.vero.w.enya,oc:ror TOTAL 55.00 Dsf DEFL RATIO: L 210 TC: L 18 Job Name: BRANDL TWIN Truss ID: P Q: 10 JID: 376877 9RG %-LOC RFAR SI2E REp'D TC 3x1 SPF C1650F3 SE IMb braclnq noutrM at eecM1 lo<adon zhwm. TMS Eesiqn Eesod on cMrd braclnp appHeO 1 0- 2-12 ]39) 5.50" 3.01" 2v1 SFF C1100F1.8E 1-3 ~$Oe :vrmre 0evtls (TX0108]001-001 ravi). par Me follwinq scheEule: 2 39- 3- 4 2173 5.50" 3A1" 2v6 SPF C1650F1.5E 6-7 [PMJ~LATE MOIIITON USED-See Joint Report•' max O.C. fran xo BRG REpVIREMEMfS sham are EnseE ONLY g~ 3x4 SPF I1/N2-CAX pes10nb De/ AMSI?PI 1-3003 TC 24.00' 21- 0- 0 30- 0- 0 on the truzs maierlal at aach baaNnO 3x0 SPF C2100F1.8E 630 Thts e.:ion aw: mt acrnunt for lonq ierm UPLIR RFARION(5) : Bra React Up11Tt Req'E 51xe y~B 2x4 SPF N1/N2-GN Hv EepnEent loW1n0 («KD)Bu11d1np SupporC Matn MnE Non•M1nE 1 239) -159 3.W" 2.3 SPF I3-UN 1-9, 4-11 Oestpner must attount fot cMS. 1 -159 lb 2 3113 -R6 3.11 ]MI SPF M3-CAN 15-1 R.t.r Co ]olnt QC Oaia11 Sheet Por ] •139 lb hFDLE 2a6 SPF C1650F1.SE Muimum Rovctonal Tolvance useE Xtp-DroO : 0-1-12 LuMer sMar allorables ere Oer HDS. TNIS DESIQI IS TME COtlVOSIIE NESULT OF ih15 truss 1s 0ev1Cned uflnp iba I0.C/IBC irv[s pLn valuee an Eas.E on XOLTIiLE LMD GSES. AS[E)•OS N1nE $peHHUtlon test1ny anE approval as r .qulnd by IBC 1703 IF I4WGER5 ARE INOIGTFD ON THIS DRAXIIlG, Bltly EncleseE ~ ria, Sspornnn Fattor . 1.00 pa W ANSI/TVI inC are re port.C tn avaiLbL TXEY A0.E 615ED ON 3.5" IWi4E0. XAIL$ F00. TrYSS LOwYton . XOL EM ZOm FLECTIN)I and L~~OE30" p.100(LIVE)T.C O1M Ora1 ~pentsomustEWFpw1 a~ioravoed ponGtnp. 1NN~CEERSNMUSTZBE AE!EVAIWTFDp(BYSOTFE0.5). Ff~an' m~f hal0hi~.~13.b68TC~x~pe h~r~.00 fi ainut nfire[R iM[[5: EnC vortluls an devlpntE for azta7 loaES ASCEI II Sundard Occupanq pad LoaE . 33.0 O,t iC M~. A/ TpS. p, C9 MIIY YOIeSi noNO oMVw1f4. Ms10md av Ms1n N1nd Porce ~If51iC10 SySSYIn 1-} -3A) 6Y U.N EY(af1S1Mi abOVf 0r bl1qY th[ tfY!{ fOT1l• • LAY•r13e ind CPfi OflelISS 6~d Clddd~Il ]-3 -3113 l.l / 1]9 .64 O.Si ~ P 9 -]t59 t,t / if~ .w o.n Uf any7 have bun a.ma..a ro. loaES' THWtary Aru - 19 sph ~-S -}ID i.l / 3U 1.6~ D.1] 1ndltltb OOly. !br$OfIU) lOddf ipp~Ud LC 5-6 -~6M 3.1 / 3)~ 1.60 0.% t11e !OE OT Che !%[oOf10nf h6V. Iro[ MVI s-r -an o.ss censiEend unlrss shmm. A droD-1e0 m an REPAIR- x cau. nn. i rtNS. cst ethinvise unsuyported rall wy aean a TNE T.C. IS BROKEN 3" TO TME RIGHT OF 70IM s. e4 av i. / aew i.t oas Mnp~ dfmcx xl~et rpulros ¢EElttonal Gstpn AlL PUTES, IINLE55 OTHERYSSE NOTED, sao n I ino coniiE.ranon (ey osnvs). MUST 9E IMRR AND PRESSED IN THE 1041 474 3.6 / 3T0 15 OJ) u-~: au ~.an oaa MJ00 VER TPI. Il-ll dll 1. / 13K .6 OJl 13-1~ -Ill 1.60 / ll99ldf 0.9 u-ss -u a~3 i 221I-0 F 8-0-0 ~ 9-6-0 ~ • ADFAWTELY S11PPoItT THE TRU55 wx conr s~ UNTIL TXE REPAIF IS COMPLETE. 2 c -s -a5~a5/ u3 .~o oa~THE METAL LUSSET PLATES AT THIS JOIM ? 3 4 5 B 7 • ATTACH THE SGB(5) AS SPEQFIED '-1 -~3 i.a / sw is o.'jMUST BE UNDAMAGEO INTACT AND PRESSED ~M W/lOd ON FACH SIOE OF THE BREAK. -ss au i in so o.vnIN TXE YqOD PER T • P05ITION THE RILHf END OF THE SGB AT JOTM 5. s-ss -n ~.soi uss :~s a.~I ON ALL THE MEMBENS. ` 54i -603 1.15 / ~o so oafTHE REPAIR SPEQFIED REQUIRES THIS. 7.4A0 DISTRIBUTE THE NAILS EVENLV. id] -H 1.60 / ~W .IS 0.10 6-14 -i:n i.as i vo ~.co a.n 2X4X12'tl1/#2 SGB 1&10d 5X7 (B J. ao a'si ~ EACH FACE 1&100 3X S+4X8 5XB 11$6 12 t5 1.5X3 SHIP I V aXB 6- 1 0 8E 3X4 S=4X8 4X4 5X8 l B1 5X5 S>4X4 3%4 BZ ' W.50B W.508 R2397 R 2173 U:.159 Ui128 1 IIF.NI:BY Q:N fIFY 1'lIA'1"I 1115 PI.AM. SP4: ~ 39~ CIPICATIOtl. UR REPON7 ~~AS PREPAREO ~B 9 1011 1713 ~q ~5~ BYMEORUNDERM\'OIRECfSGPER\'ISIOY ANp "1'HA f I AM A 1161.1 Ht:CIS fF.R1:D PN(1- FESSIONAL ENCI[1EEN U~DfR TIIE LAN'S OiT11CS1' O~\II.V 5 TA. C.F..ALTER ~ T Aummamrolah+rO Twwal¢apaorW«e 20 pa.,unlmpeceaa `HB^iwHefo aPhrDllBpaRmmAlplnr DAPt: NCC151'MA'I'10\?0.3J96b TRl15PLU5 6.0 VER: T6.5.7 o~DneMWEy•YII'brt1NM%i0p..m'H•Ia18Q~.M1OmTeuiwal0W~o~.ao.r~am8x.nx ort: ara.avia...~drr.. ~f ~f rt~m~ ontn r~ ooqaon.a n.rorm ao~. snn wue qw oms io..aa o..nw wam sc rc~ur:Scir..lv nwl.l. 7/~fLL/L0O8 147 - A. B. C. Mo~ tN~ se WARNINGRead all notes on thla aheet and glve a rnpy ollt to the Ereeting Con6actor. Cusc: Lrr~aN Luwaea / cww. ~ M mi.aW~ue..~wnawwmna<a.ownnaw..mwn.nro.e..nev.ama.rmmamomwrM»mmw~~+m.v.a..r IYO: DrivdS_e87972100005,00001 .eaen.msewa.nu.meeemn.nem.sm.iawc.aupnena.a. wmpamooyi.mo.enxam.nm.jsamay anwas Dsqnr: 7LM fLC = 34 Wf: 253M niarwnaeyim~aepanwmnu~ewr.meuavpawpivpnwmr~sseen ttieuw~perpvmwm~wiwmmm TRUSWAL ~~~~~mr~rr.ru.wanoMroraeywanio-uaeyma.nan.w~W,wor~~ ~aaonaw.mm~wapmue TC Live 35:00 pzf DurFacs L=1.15 P=1.15 e~+r+Nw.seWm.~.r>~m,a..uu~ywimemammuaaw.M~uaer.npuwwmommian.nye.a.a.mrem.r~a TC Dead 10.00 sf Rep !4r Bnd 1.30 nn.e.am~yna.nnrnr.~wwcw~d~aanawmm..w.elMmi.e~.mamosnd~ ms<m~om.nanme.cuuaM.rv P ReV A4r CanP 1.10 57"i SYSTEMS e"*^^"^ffl^r`aume.manu.een.vww.maanu.eu%nweraw.mw.v'a.mmmn.r.eaneC Live 0.00 psf ReP Mbr Tena 1.10 na a.uw ww n.xwmrc. wnx. raeMw a.na.a:xui.m cwna wm nwav..w.u. eadianmm rhemmwm.m. ROVBUWInpCOmponam. Oroup,lnc. ANS"i1.yyrMA i•.weearNncanmaAm.ra a.eeaowpnW.pnmm..anuwm~sarE~teArxnosaaunon- BC Dead 10.00 Psf O.C.Spacin9 2- 0- 0 waw"wnv. s im, uo- ryp, roSwe? ~euim~maeenw~surtreireneyvnc~nam m.maor.umwtmndema+enw~m~com..wasm. Desipn Spec IRC-2006 Wvi~FH~If.il~~MwknFan~utlVqw~wtl~MyJV~)YIwWtl1111~pR~M,MN.9~M0,W~tltlnOcn,OC]Wd6 TOTAL 55.00 Dsf IDEFL RATIO: L NO TC: L 18 2017-Sep-13 02:17 PM Greenguard Construction 507-208-4336 2/13 Use BLUE or BLACK Ink For Office Use r ' 1 -1 )1 City of Bakal Permit#: �� �� 3830 Pilot Knob Road Permit Fee: 2 �' C Eagan MN 55122 M.. Date Received: 9jr'l f� Phone:(651)675.56713 buildlnainsoectionstEEcitvofeaaan.cont Staff: 2017 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 9/1 3/1 7 Site Address:4892 Twins Court « (,) Unit#: Name: Homestead Village HOA Phone:Ali (612)242-0754 Resident/ Owner Address/City/Zip: Applicant Is: Owner X Contractor Description of work: Re-Shingle Dwelling Type of Work {� 0 Construction Cost: 15'000'00 J f O Multi-Family Building:(Yes X/No_) • Company: GreenGuard Construction Contact: Pat Addy Contractor Address: 2915 Waters Road #101 City: MN 55121 (812)750-2033 Cell pet.addy@greenguardconstruction,com State; Zip; Phone: Email: License#: BC633970 Lead Certificate#: nat103540-2 If the project Is exempt from lead certification,please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING in the last 12 months,has the City of Eagan Issued a permit for a similar plan based on a master plan? _Yes Jho If yes,date and address of master plan: Licensed Plumber; Phone: Mechanical Contractor: Phone: Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents that you submit are considered to be public Information. Portions of the Information maybe classified as nonpublic If you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's wabeite at www,cltvofeaaan.comisubsoribo. Exterior work authorized by a building permit issued In accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance, CALL BEFORE YOU DIG.Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities, www•aoeheretsteonecall.arq I hereby acknowledge that this Information le complete and accurate;that the work will be In cont.••-. co with the ordinances and codes of the City of Eagan:that I understand this Is not a permit, but only an application for a permit,and work : not 1. alert without a permit; that the work will be in accordance with the approved plan In the cave of work which requires a review and approval plane. xPat Addy Applicant's Printed Name Applicant's Signetu rti Page 1 of 3 PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA145371 Date Issued:09/07/2017 Permit Category:ePermit Site Address: 4892 Twins Ct Lot:18 Block: 01 Addition: Homestead Village PID:10-33475-01-180 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Heater Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Allow an 18" minimum radius clearance to the water meter from all appliances (i.e. furnace, water heater, water softener). Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Alison L Harder-ross 4892 Twins Ct Eagan MN 55123 (612) 369-4556 Champion Plumbing 3670 Dodd Rd., #100 Eagan MN 55123 (651) 365-1340 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Mechanical Permit Number:EA167153 Date Issued:02/25/2021 Permit Category:ePermit Site Address: 4892 Twins Ct Lot:18 Block: 01 Addition: Homestead Village PID:10-33475-01-180 Use: Description: Sub Type:Residential Work Type:New Description:Air Exchanger Comments:Questions regarding electrical permit requirements should be directed to State Electrical Inspector, Pete DeGrood at (507) 210-0754. Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Fee Summary:ME - Permit Fee (Replacements)$59.00 0801.4088 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Alison L Harder-ross 4892 Twins Ct Eagan MN 55123 (612) 396-4556 Burnsville Heating & Air Conditioning 3451 West Burnsville Parkway, Ste. 120 Burnsville MN 55337 (952) 894-0005 Applicant/Permitee: Signature Issued By: Signature