Loading...
1478 Wellington Way 07/16/2007 09:26 6128252303 RAY N WELTER HEATING PAGE 02I02 Date: 7113107 Revision Date: 7/9 3/07 New ConstruCtion site Info?mation Address 1: 1478 Wellington Way Project Ste"lechase of Eagan Address 2: Lot: #25 BioCk: City: Eagan County: . 5ubdivision: A lication Information Business Name: Ray N Welter HVAC MN Contractor License Contact Person: JOE Office Ph: 612-8256867 Fax: Cell Ph: Address 1: 4637 Chicago Ave. So. City: MPLS. State: MN. Zip Code: 55407 House Detaiis Square Feet: 6144 sq. ft. Avg. Ceiling Ht: 11.2 Number of Bedrooms: 8 ft. Ventilation : Balanced Total Ventilation Capacity : 300 cfm. Minimum Continuous Ventilation :105cfm. Intermitterit Ventilation: 195 cfm. Combustion AoWiance Water Heater: Power Vent Input BTUs: 80,000 Independently Vented FumacelBoiler 1: Direct VenUSealed Combusfion Input BTUs: 120,000 Independently Vented Fumace/Boiler 27 Direct Vent/Sealed Combustion Input BTUs: 80,000 Independently Vented Other CombusUon Apallances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Verrt Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust E,quipment Continuous Exhaust Ventilation Capacity (cfm): NA Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 700 pAake-Ua Air No Make-Up Air Required by Code DLrE~~'~ Combustlon Air . JUL i 6 2001 D Round Rigid Required: 4 inches or Insulated Flex: 5 inches By Applicant Name (print}: G/TC,.. ,/fGfpf4 Signature/Date: ~ If Code Officiat (print): $ignature/Date• 0 2004 CenterPoint $nergy Minnegasco. 2004 Mechanical Codc Guidelints. psge t 9L '7665~p i . ' ~-0 1 _ 40,Sc ° ~L 76(0~~ ~ `a~RESIDENTIAL BLTII.DING rExmsr r.rrLicAlzoN ; ciryofEagan ~lE -7~~s`~ qn,• ~D 3830 Pilot Knoh Road, Eaga¢ MIN 55122 ---I Telephone # 651-675-5675 FAX # 651-675-5694 J0) /D Li . NewknsWdionReourtements. RemodellReoahRevuiremenfs n v/3 re9flered sfle surveys showinp sq. R ot lof. sq. ft. of hau& and atl mofed areas 2 eopfes oi plan show6u~ footings. beams. johis CaA oi Siwey Racd N (2t11 mazhmnn bt cove~age a9aued) - ; 1 sef of Enragy Celqdaflona tor hesled addkns Tree Pres P~n ReW ?2 ~Y vN. caRs Mqmi sMwk~g beam & window shes; poured~ found design. Nc. t sde survey tor additiona 8 dada T~ pm ~y~~~ . _Y ~ . V1 set f Enmgy CaiwWtions ~,3 Adddfon - brclketetlan-sAe aeptic sysfem OiNSile Sepdc Sys6mn _y AiN caRs of Tree Pieservafion Plan B kt platted aRe 711fSi / ~ . ?RYn.E'slDala00ptimust~Ctlm~eel (bu?d'o~pswah3alessunqs) ~ ~ . ?Min'tgacco cnechanical vrntilation form Da4TI ConstructionCost ~ SiteAddress - (.Jv~, • Unit/Ste# DesripBonofWork MWti-Family Bldg Fireplace(s) 1. _ 2 Telephone # J ) ~ D7 - 7-: . F(GlIktractor l C'tty y State 7,ip e3~2/ Z T. Telephone #(rp,s'1} _ COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING i . ~ 'cnergy Code Category - Minnesota Rules 7670 Cateeorv 1 _ Minnesota Rules 7672 ~ (Jsubmissiontype)- - . ResidentialVenL'IationCategory 7.Worksheet . ~qEnergyCOdeWotl¢heet . . . Submfted- . . . . --aaljmAted II I~ . • , Energy ErnelopeCakulations Submitted u W Jni~ 'too? in fhe last 12 months, has The City of Eogan issued a permii for a similar plan based on a master p1anZ _ Y ~ N If yes, date and address of master plan: A ; UCensedPlumber i?19&W4^ Telephone#("f(~ y9b' (,/nO . Mechanicai Conhactor _~Telephone #(~/Z ) 42115-- 70_S Sewer/Water Conhactor Telephone f) yRn - 13 S~ I hereby apply for a Residential Building Permit and acknowledge that the information is coaiplete and aocurat( that the work will be in coaformance with the ordinances and codes of the City of Eagan and the State of M Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without , permit; that the work wiil be in accordance with the approved plan in the case of work wluch requires a review ar aAProval of plans. ~ -~w44- .Applicant's Printed Name Apphcant's Signature \ y . . e.. ~ DO NOT WRITE BELOW THIS LINE ' Sub Tvaes ? 01 Foundation ? 07 OS-plex ? 13 16-plex ? 20 Pool ? 30 Accessory Bldg x 02 SF Dwelling ? OB 06-plex ? 16 Fireplace O 21 Porch (3-sea.) ' ? 31 E#. Alt- Multi ? 03 0 1 of _ plex ? 09 07-plex ? 17 Garage ? 22 PorchlAddn. (4-sea.) ? 33 Ext. AIt - SF ? 04 02-plex ? 10 OB-piex ? 18 Dedc ? 23 Porch (screen/gazebo/pergola) ? 36 Multi Misc. ? OS 03-plex ? 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex ? 25 Miscellaneous ork T es 31 New ? 35 Int Improvement ? 38 Demolish Interior ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demolish Building* ? 43 Reroof ? 46 Windows/Doors ? 34 Replacement 'Demolition (Entire Bldg) - Gtve PCA handout to applicant DeSCflptl0(1: Water Damage _ Yes Valuation L20d Occupancy 'cf MCES System Plan Review X-100% or _ 25% Census Code ~q~ Zoning ~ City Water SAC Units (9) Stories Booster Pump # of Units ~ Sq. F[. ~n PRV # of Bldgs 1 Length Fire Sprinklered Type of Const vWidth ~ REQITII2ED INSPECTIONS ~ Footings (new bldg) Sheetrock _ Footings (deck) ~ Final/C.O. Footings (addition) _ Final/No C.O. Foundation _ HVAC . Drain Tile Other Roof Ice & Water Final Pool Ftgs AidGas Tests Final x Framing _ Siding _ Stucco Lath _ Stone Lath _Brick ~ Fireplace 4R.I. $AirTes[ -)CFinal - Windows [nsulation Retaining Wall / Approved By: Building Inspector Base Fee 2- (7 4 3 Surcharge ~ ~j 2 Plan Review > y ~ MC/ESSAC ~/1 N"~ / D ~ 179~ 0 G"1i12. ~ity SAC ~ ?9, ~yog~/,~~ Utility Connection Charge (j r/ S&W Permit & Surcharge 2rt~(~,3j ~ 6 Treatment Plant License Search X O'~ i V v Copies Other SrooV" Total Permit Number ) y2 S ~014 k W~ REScheck Complian Certiticat Checked By/Date 2003 IECC REScheck Software Version 3.6 Release 1 Data filename: K:\ ENGINEERING SERVICES\_HVAC DEP"ll_Energy Calculations\Iv1N\Steeplechase of Eagan - Signahues\025\I3ennepin-Federal-025 Revised.rck PROJECT TITLE: Hennepin Model CITY: Minneapolis STATE: Minnesota HDD: 7981 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.17 DATE: 01/05/07 DATE OF PLANS: 0 1 /05/2007 PROIECT DESCRIPTION: Steeplechase of Eagan - Signatures 4876 Steeplechase Way Lot#025 Eagan, MN 55122 DESIGNER/CONTRACTOR: Toll Brothers Inc. PROJECT NOTES: Elevation: Federal Options: 013,017,023,070,171,188,190 532,533,900025008,900025011 Kunjal Patel Task 38327 Order 9502 COMPLIANCE: Passes Maxunum UA = 745 Your Home UA = 624 16.2"/o Better Than Code (UA) Gross Glazing Area or Cavity Cont. or poor Perimeter R-Value R-Value U-Factor UA Flat Ceiling: Flat Ceiling or Scissor Truss 1872 44.0 0.0 51 Sloped Ceiling: Flat Ceiling or Scissor Tmss 706 44.0 0.0 19 Skylight 1: Vinyl Frame:Double Pane with Low-E 16 0.400 6 Mics. Ceiling: Flat Ceiling or Scissor Truss 157 44.0 0.0 4 Wall Ceiling: Flat Ceiling or Scissor Truss 39 44.0 0.0 1 Garage wall: Wood Frame, 16" o.c. 442 19.0 0.0 26 Door 5: Solid 17 0.200 3 Knee Wall: Wood Frame, 16" o.c. 181 13.0 0.0 15 Band Joist: Wood Frame, 16" o.c. 263 19.0 0.0 16 Exterior Wall 6": Wood Frame, 24" o.a 2713 19.0 0.0 126 Window 2: Vinyl Frame:Double Pane with Low-E 474 0.360 171 Door 7: Solid 37 0200 7 Door 8: Glass 60 0350 21 Basement Wall I: Solid Concrete or Masonry 1777 OA 11.0 98 Wall height: 8.5' Depth below grade: 7.5' Insulation depth: 7.5' Window 3: Vinyl Frame:Double Pane with Low-E 75 0360 27 Door 9: Glass 40 0.350 14 Floor Over Garage: All-Wood 7oisvTruss:Over Uncondirioned Space 580 30.0 0.0 19 Fumace 1: Forced Hot Air, 92 AFUE Air Conditioner 1: Electric Cenual Air, 13 SEER COMPLIANCE STATEMENT: The proposed building desi{,m described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release 1(formerly MECcheck) and to comply wi[h the mandatory requirements listed in the REScheck Inspection Checklist. I herecy ccrtify that this plan, speci- Builder/Designer fication nr rrnT rr w»c nrena,r.d iry Date /50; 07 me ar under aiy direct supervision and that 1 am a duly Licc:nsed Frolessiunal Enguieir w:der the laws of'ihe Staic of hiiancsolu. Priut Nume: SA M. GROSSE Siy.-~ature: Date I ~ Lice #44835 C~ o REScheck Inspection Checklist 2003 IECC REScheck Software Version 3.6 Release 1 DATE: 01/05/07 PROJECT TITLE: Hennepin Model Bldg. I Dept. ~ Use ~ I ~ ceilings: ~ 1. Flat Ceiling: Flat Ceiling or Scissor Tmss, R-44.0 cavity insulation ~ Comments: ~ 2. Sloped Ceiling: Flat Ceiling or Scissor Tmss, R-44.0 cavity insulation ~ Comments: ~ 3. Mics. Ceiling: Flat Ceiling or Scissor Truss, R44.0 cavity insulation ~ Comments: ~ 4. Wall Ceiling: Flat Ceiling or Scissor Tmss, R-44.0 cavity insulation ~ Comments: ~ ~ Above-Grade Walls: ~ 1. Gazage wall: Wood Frame, 16" o.c., R-1 9.0 cavity insulation ~ Comments: ~ 2. Knee Wall: Wood Frame, 16" o.c., R-13.0 cavity insularion ~ Comments: ~ 3. Band Joist Wood Frame, 16" o.c., R-19.0 cavity insulation ~ Comments: ~ 4. Exterior Wa116": W ood Frame, 24" o.c., R-19.0 cavity insulation ~ Comments: ~ I Basement Walls: ~ 1. Basemen[ Wall 1: Solid Concrete or Masonry, 8.5' hd7.5' hg/7.5' insul, ~ R-11.0 continuous insulation ~ Comments: ~ Exterior insulation must have a rigid, opaque, weather-resistant protective covering that ~ covers the exposed (above-grade) insulation and extends at least 6 in. below grade. ~ Windows: ~ 1. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.360 ~ For windows without labeled U-factors, describe features: ~ # Panes Frame Type Thermal Break? Yes No ~ Commen[s: ~ 2. Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0360 ~ For windows without labeled U-factors, describe features: ~ # Panes Frame Type Thermal Break? Yes No Comments: ~ ~ Sky6ghts: ~ 1. Skylight 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.400 ~ Foz skylights without labeled U-factors, describe featuies: ~ # Panes Frame Type Thermal Break? Yes No ~ Commenu: I ~ Doors: ~ 1. Door 5: Solid, U-factor: 0.200 ~ Comments: ~ 2. Door 7: Solid, U-factor: 0200 ~ Comments: ~ 3. Door 8: Glass, U-factor: 0350 ~ Commenu: ~ 4. Door 9: Glass, U-factor: 0.350 ~ Comtnents: ~ ~ Floors: ~ 1. Floor Over Garage: All-Wood JoisUTruss:Over Unconditioned Space, ~ R-30.0 cavity insulation ~ Comments: ~ ~ Heating aud Cooling Equipment: ~ 1. Furnace 1: Forced Hot Air, 92 AFUE or higher ~ Make and Model Number ~ 2. Air Conditioner 1: Electdc Central Air, 13 SEER or higher ~ Make and Model Number ~ ~ Air Leakage: ~ Joints, penetrations, and all other such openings in the building envelope that are sowces of air ~ leakage must be sealed. I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropnate air-tight assembly ~ with a 0.5" clearance from comhustible materials. If non-IC rated, the fixture must be installed with a ~ 3" cleazance from insularion. I ~ skylignc5: ~ Muumum insulation requirement for skyligh[ shaf[s equal to or greater than 12 inches is R-19. ~ ~ Vapor Retarder: ~ Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. ~ ~ Materials Identification: ~ Materials and equipment must be installed in accordance with the manufacturer's ins[allation instructions. ~ Materials and equipment must be identified so that compliance can be deterniined. ~ Manufachuer manuals for all installed heating and cooling equipment and service water heating ~ equipment must be piovided. ~ Insulation R-values, glazing U-fac[ors, and heating and cooling equipment efficiency must be clearly ~ mazked on the building plans or specifications. ~ ~ Duct Insulation: ~ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ~ Return ducts in unconditioned attics or outside the building must he insulated to R-6. ~ Supply ducts in unconditioned spaces must 6e insulated to R-11. ~ Re[um ducts in unconditioned spaces (except basements) must be insulated to R-2. ~ Where exterior walls are used as plenums, the wall must Ue insulated to R-11. ~ Insulation is not required on return ducts in basements. ~ ~ Duct Construction: ~ Duct connecrions to flanges of air distribution system equipment must be sealed and mechanically fastened. I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), ~ mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. ~ Exception: Continuously welded and locking-type longitudinal joints and seams on ducts ~ operating at less than 2 in. w.g. (500 Pa). ~ The HVAC system must provide a means for balancing air and water systems. ~ ~ Temperature Controls: ~ Thermostats aze required for each separate HVAC system. A manual or automatic means to ~ par[ially reshict or shut off the heating and/or cooling input to each zone or floor shall be provided. ~ ~ Service Water Heating: ~ Water heaters with vemcal pipe risers must have a heat trap on both the inlet and outlet unless the ~ water heater has an integral heat trap or is part of a cuculating system. ~ Insulate circulating hot water pipes to the levels in Table 1. ~ ~ Circulating Hot Water Systems: ~ Insulate circulating hot water pipes to the levels in Table 1. ~ ~ Swimming Pools: ~ All heated swimnung pools must have an on/off heater switch and requue a cover unless over 20°/o ~ of the heating energy is from non-depletable sources. Pool pumps require a ticne cbck. I ~ Heating and Cooling Piping Insulation: ~ HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the ~ levels in Table 2. Table 1: Minimum Insulafion Thickness for Circulateng Hot Wa1er Pipes. Insulation Thickness in Inches bv Pipe Sizes Heated Water Non-C'vculatine Runouts CucularinQ Mains and Runouts Temnerature ( F) Un to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pining System Tvpes Ran e F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Headng Systems Low Pressure/1'emperamre 201-250 1.0 1.5 1.5 2.0 LowTemperature 120-200 0.5 1.0 lA 1.5 Steam Condensate (for Feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: Loi s- dC. Se- OF DATE OF SURVEY: 8 LATESTREVISION: 11/2107 m ~ c R L U 9 O z ¢ DOCUMENT STANDARDS ,d . Registered Land Surveyor signature and company ~ ? ? • Building Permit Applicant ? ? • Legaldescription ,.E ? ? . Address Rf • North arrow and scale • House type (rambler, walkout, split w/o, split entry, lookout, etc.) . Directional drainage arcows with slope/gradient % ja • Proposed/existing sewer and water services & invert elevation )3 ? ? • Street name '9 • Driveway (grade 8 width - in R/W and back of curb, 22' max.) ya ? ? . Lot Square Footage '0 ? ? • Lot Coverage , ELEVATIONS Existin 'z ? ? • Property comers .z • Top of curb at the driveway and property iine extensions ?'R ? • Elevations of any existing adjacent homes g . Adequate footing depth of strudures due to adjacent utility trenches 0 y1" ? • Watenvays (pond, stream, etc.) Proposed , [d p ? • Garage floor ~ ? ? . Basement floor 'z ? ? • Lowest euposed elevation (walkoutlwindow) • ? ? • Property corners fd • Front and rear of home at the foundation . PONDING AREA (if appiicable) ? fa ? • Easement line ? fd . ? • NWL 0 J0 ? • HWL ? pl ? • Pond # designation . ? [d ? . Emergency Overflow Elevation ?J21 ? • PondlWetland bufferdelineation SJ~~{/(quS~. G)C.S~, Y ~ • Shoreland Zoning Overlay District Y ~ • Conservation Easements So-44ack adjace,4 ./.o DIMENSIONS nJJNa/4P./S iS /p F4. ,B • Lot lines/Bearings & dimensions 5t`'?r^/ ~o~'S S S;4_ .2 p? • Right-of-way and street width (to 6ack of curb) fa- . Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring pertnanent footings) n~? ? • Show all easements of rewrd and any City utilities within those easements ?.0 • Setbacks of proposed structure and si ard setback of adjacent existing structures ~ ? ? • Retaining wall requirements: Reviewed By: Date-//~ST G:lFORMS/Building Permd Application Rev. 11-26-04 lIZ9107 .•P • ~ ~ Certificate of Survey OF Top 98 5t i 568~46~'3¢ ~E __Top tP 1478 WELLINGTON WAY 9 zos 43 ~ 991.76 o - I ,"C;` _ - - o -o - ~ - - 0 t0.3 A9ry _0 ~ O 1 . 10' Setbock Line ~ ~48o~ ~ +~~,i ~ io~ TOLL BROTHERS , ~ pOp ~ g s. ~ ~ f ~ 1400 Corporate Center Curve - I'~ L a lproposed hous~e- ~,ry~Ati Eagon, MN Zip 55121 ~ ~ o a~ 9' po~u ed I v ' 2 "n ~ 1 ,41 0- , 1valkou~ 6asement ~,3 : / ~^j " / ~ f , ,W a " + 3:1 RAattimum Slopes ~ I w + a ~'j ~ / r ' ~ d` ^ R~s4aining Wail lAJill ~ t~l ry 5 n of ? ~ ~ B8 FieqUlred ond oter s b per ~ g. ti ~ RLK Kuusisto plon A~ y N a°j Proposed/ ~ o ~ ~-r-'Driveway ha_- 5.4% oposed ~ o o ~~,ry + ~9_ ry 9ti. 3 ~ garage 18.2°~h. ~3 c~ A11_~ ~ . 0 20 0 43.5 - t--- ~ 5•3 ~ SCA ~ ~ ~,v VV I II ~N ~ ~ry 'o 21.2 - 1 10 ~ 5' Setbaak ~ine ~ PROPOSED AREAS 55.97 pN ^I - V ~ 99_ z Area of Lot 5, Blxk 5=17.816 Sq. Ft. Top fP 183.52/ss 'S625'E _ Proposed House = 3155 Sq. Ft. 998.31 9ry / 492.56 ap Percent of Lot Covero9e= 17.7% ..y ~ . , vi ~4 PROPOSED ELEVATIONS WO House By _ LEGEND Garage left Garage floor elev. = 7000.8 = Iron monument found = Drainage Direction Minimum lowest floor ~~~~0~ ~ rop of block eiev. = 1001-2 O= Iron monument set and marked -840- = Proposad 10' contours from grading plan elevation = 992.5 ~~940EMG DE". with license No. 23968. -842- = Proposed 2' contours from grading plan Lowest floor elev. = 992.5 D San. Sewer Stub Elev.= 985.8 0= Offset iron -840- = Existing 10' contours m Bearings shown are assumed = -8a2- = Existing 2' contours Drowing Flle: 700\15.85 DWG j = Droinoge dc Utility Easement L o t 5, 1 o e k 5 = EX=gt,n9 sanitory sewer Project No. 2006-408-L ~ %eoo.o = Ex(sting Elewtton 12/213/06 = Exfatin storm sewer _ 9 Toll Bros. Code= # 25 o Proposed devotion from grode - I - = Extsttng water ° ST E E P L E C E a development plan oa = Cu~ bax ~ omooo= Retaining Wall P4 _ Gat6 val`re ^ Duluth, MN. m C~ I hereby certify that this survey, pian or report wos prepared by Hibbing, MN. ~ Ham Lake, MN. ~ 7-7 me or under my direct supervision and fhat 1 am a du ly License d OFEAGAN R1.aK Minnetonka, MN. ;o 11.2 Land Sur under the, ~ of the State of Minnesota. Pnone_ (952) 933-0972 DAKOTA COUNTY, MINNESOTA J ~ ~ X. JonUOry 8, 2007 ~ Fax: (952) 933-1 753 Subject to easements of record, if any. -m ~ Kurt M. Kisch, MN License No. 23968 Date www_rlk-kuusisto.com Rev.: 1-12-07 S?ide House; 4.5 feet 6110 Blue Circle Dr. •Suite #100 •Minnetonka, MN. 55343 ;o Peimit Number REScheck Compliance Certificate checkeasyinate 2003 IECC REScheck Software Version 3.6 Release la Data filename: K:\ ENGINEERING SERVICES\_HVAC DEPT'\_Energy Calcularions\NlN\Steeplechase of Eagan - Signatures\022\Pepin-Provincial-022-Revised-07-16-07.rck PROJECT TITLE: Pepin Model CITY: Minneapolis STATE: Mimmesota HDD: 7981 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.16 DATE: 07/17/07 DATE OF PLANS: 07l17/2007 PROJECT DESCRIPTION: Steeplechase of Eagan - Carriages iy' 0 ~ Eagan, MN 55122 DESIGNER/CONTRACTOR: Toll Brothers Inc. PR07ECT NOTES: Elevation: Provincial Oprions: 017, 023, 025, 151, 187, 190, 367, 90002207 9002012, 900022014,900022015,900022028 Kunjal Patel Task 55843 COMPLIANCE: Passes Maximum UA = 816 Your Home UA = 683 16.3% Better Than Code (UA) Gross Glazing Area or Cavity Com. or poor Perimeter R-Value R-Value U-Factor UA Flat Cefling: Flat Ceiling or Scissor Tmss 1726 44.0 0.0 47 Wall Ceiling: Flat Ceiling or Scissor Tmss 32 44.0 0.0 1 Sloped Ceiling: Flat Ceiling oz Scissor Tmss 704 44.0 0.0 19 Skylight 1: Vinyl Frame:Double Pane with Low-E 16 0.560 9 Gazage wall: Wood Frame, 16" o.c. 327 19.0 0.0 19 Door 5: Solid 17 0.200 3 Knee Wall: Wood Frame, 16" o.c. 795 13.0 0.0 65 Band 7oist: Wood Frame, 16" o.c. 271 19.0 0.0 16 Exterior Wa116": Wood Frame, 16" o.c. 3024 19.0 0.0 142 Window 2: Vinyl Frame:Double Pane with Low-E 615 0.350 215 Door 7: Solid 40 0.200 8 Basement Wall 1: Solid Conciete or Masonry 1735 0.0 11.0 96 W all height: 8.5' Depth below grade: 7.5' Insulation depth: 7.5' Window 3: Vinyl Frame:Double Pane with Low-E 69 0350 24 Door 9: Glass 42 0340 14 Floor Over Garage: All-Wood JoisU'Truss:Over Uncondirioned Space 139 30.0 0.0 5 Furnace 1: Forced Hot Air, 92 AFUE Air Conditioner 1: Electnc Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit applicarion. The proposed building has been designed m meet the 2003 IECC requirements in REScheck Version 3.6 Release la (formerly MECcheck) and to comply with the maUcIMpn?~r~r~~q&T~t~sip~xc~a~ th~F Scheck Inspection Checklist. ficatiorM or;ep,)rt wa ,^.rcpazed by Date Builder/Designer mr nr a~...,3. .r .•-ea~ a,1 flh4! 1 z~n 1! daiv :,icer.:=rd ~~'>crt,:!!a tha Y:iws of u,c u: P.'ii;,nesvta. Prin! Nzm e: ' ;SA M. t:ROSSE Signature: I Data 9l Lic 944835 REScheck Inspection Checklist 2003 IECC REScheck Softwaze Version 3.6 Release la DATE: 07/17/07 PROJECT TITLE: Pepin Model Bldg. ~ Dept. ~ Use ~ ~ ~ Ceilings: ~ 1. Flat Ceiling: Flat Ceiling or Scissor Tntss, R-44.0 cavity insulation ~ Conunents: ~ 2. Wall Ceiling: Flat Ceiling or Scissor Tmss, R-44.0 caviTy insulation ~ Conunents: ~ 3. Sloped Ceiling: Flat Ceiling or Scissor Truss, R-44.0 cavity insulation Conunents: ~ ~ AbovrGrade Walls: ~ 1. Gazage wall: Wood Frame, 16" o.c., R-19.0 cavity insulation ~ Comments: ~ 2. Knee Wall: Wood Frame, 16" o.c., R-13.0 cavity insulation ~ Comments: ~ 3. Band Joist: Wood Frame, 16" o.c., R-19.0 cavity insularion ~ Comments: ~ 4. Exterior Wall 6": Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: ~ ~ Basement Walls: ~ 1. Basement Wall 1: Solid Concrete or Masonry, 8.5' htl7.5' bg/7.5' insul, ~ R-11.0 conrinuous insulation ~ Conunents: ~ Exterior insularion must have a rigid, opaque, weather-resistant protective covering tha[ ~ covers the exposed (above-grade) insularion and extends at least 6 in, below grade. ~ ~ Windows: ~ 1. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0350 ~ For windows without labeled U-factors, describe features: ~ # Panes Frame Type Thermal Break? Yes No ~ Conunents: ~ 2. Window 3: Vinyl Fiame:Double Pane with Low-E, U-factor: 0350 ~ For windows without labeled U-factors, describe features: ~ # Panes Frame Type Thermal Break? Yes No ~ Conunents: I ~ Skylights: ~ 1. Skylight 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.560 ~ For skylights without labeled U-factors, describe features: ~ # Panes Frame Type Thermal Break? Yes No ~ Commenu: ~ ~ Doors: ~ 1. Door 5: Solid, U-factor: 0.200 ~ Comments: ~ 2. Door 7: Solid, U-factor: 0.200 ~ Comments: ~ 3. Door 9: Glass, U-factor: 0340 ~ Comments: ~ ~ Floors: ~ 1. Floor Over Garage: All-Wood JoisUTmss:Over Unconditioned Space, ~ R-30.0 caviTy insularion ~ Commenu: ~ ~ FIeating and Cooling Equipment: ~ 1. Ftunace 1: Forced Hot Air, 92 AFUE or higher ~ Make and Model Number ~ 2. Air Condirioner 1: Electdc Central Air, 13 SEER or higher ~ Make and Model Number ~ ~ Air Leakage: ~ Joints, penehadons, and all other such openings in the building envelope that aze sources of air ~ leakage must be sealed. ~ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-right assembly ~ with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a ~ 3" clearance from insularion. ~ ~ Skylights: ~ Minimum insulation requirement for skylight shafrs equal to or greater than 12 inches is R-19. ~ ~ Vapor Retarder: ~ Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. ~ ~ Materials Identification: ~ Materials and equipment must be installed in accordance with the manufachuer's installation instrucrions. ~ Materials and equipment must be identified so that compliance can be deternvned. ~ Manufacturer manuals for all installed heating and cooling equipment and service water hearing ~ equipment must be provided. ~ Insularion R-values, glazing U-factors, and heating and cooling equipment efficiency must be cleazly ~ marked on the building plans or specifications. ~ ~ Duct Insulation: ~ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ~ Return ducts in uncondiHoned attics or outside the building must be insulated to R-6. ~ Supply ducts in unconditioned spaces must be insulated ro R-11. ~ Return ducts in uncondirioned spaces (except basemenu) must be insulated to R-2. I Where exterior walls are used as plenums, the wall must be insulated to R-11. ~ Insulation is not required on return ducts in basements. ~ ~ Duct Construction: I Duct connections to flanges of air distnbuuon system equipment must be sealed and mechanically fastened. ~ Alljoints, seams, and connections must be securely fastened with welds, gaskets, masrics (adhesives), ~ mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. ~ Exception: Continuously welded and locking-type longitudinal joinu and seams on ducu ~ operating at less than 2 in. w.g. (500 Pa). ~ The HVAC system must provide a means for balancing air and water systems. ~ ~ Temperature Controls: ~ Thermostats are required for each separate HVAC system. A manual or automatic means to I ~ partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. ~ ~ Service Water HeaHng: ~ Water heaters with vertical pipe risers must have a heat hap on both the inlet and outlet unless the ~ water heater has an integral heat trap or is part of a c'uculating system. ~ Insulate circulating hot water pipes to the levels in Table 1. ~ ~ Circulating Hot Water Systems: ~ Insulate circulating hot water pipes ro the levels in Table 1. ~ ~ Swimming Pools: ~ All heated swimming pools must have an on/off heater switc6 and require a cover unless over 20% ~ of the hearing energy is from non-depletable sources. Pool pumps require a time clock. ~ ~ Heating and Cooling Piping Insulation: ~ HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the ~ levels in Table 2. I Table 1: Minimum Insulation Thickness for Circulating Ho! Water Pipes. Insulation Thickness in Inches bv Pine Sizes Heated Water Non-Circula[ine Runouts Circulatine Mains and Runouts Temnerature ( F) Uv to 1„ Un to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 1: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thiclmess in Inches by Pine Sizes Pinine Svstem Twes Ran e F 2" Runouts 1" and Less 1.25" ro 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Clrilled Water, Refiigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Departrnent Use Only) ~ N`?"oll Architecture ~ ; February 6, 2007 : ~ Chad Canoll r Steeplechase of Eagan - Signatures r 4876 Steeplechase Way r Eagan, MN 55122 (,vjQ LL LA4-7"8'"j lk~ r ~ r RE: Hennepin - TBI Lot #025 ~ Dear Chad, ~ r For TBI Lot #025, I have reviewed the construction documents for structural integrity. I r find no exceptions to the roof framing, floor framing, and foundations including "tall . wall" assemblies and garage portal stability. Note that the stud framing shown on the . construction documents have a maximum deflection criteria of spaiV240 for the : Foyer wall and span/180 for all other "tall walls" under wind loading per ASCE 7-98. ' If you have any questions or concerns, please do not hesitate to call. ~ Sincerely, ~ r Toll Brothers, Inc. ~ I liorc5y ceWTy thst ihis p'.an, sgcci- ~ ficaxioa, or report was E;m^ared by r me or u.dr,t;ny dir-ci supfrvision r and that I a~ a und. Lic:nsed F Pro;css:onsl Gri iacer ~:r,cizr the r ~ laws of e:c S:ate of [:;iWaesota. r ~ Pruu Nacie: LISA hL GROSSS r- Signatnre: w . r Date?,L~o 7 Licei~ 944835 ~r Lisa M. Grosse, P.E. Assistant Director of Engineering " MN License #44835 CC: Jerry Lamina LMG/11 •SESG 1tr0020 •SPR #24594 Task #42356 •r r r r r r ~ EASTERN D[V[S[ON ~ 250 Gibraltar Road 0 Horham, PA 19044 o (215) 2935300 o FAJ{X (215) 293-5313 ~ PHILADELPHIA o ORLANDO o SCOTTSDAL6 m DALLAS m DENVER m LOS ANGELES r A `7011 `Brothers CO:uP,4,VY ~ . INSULATION INSPECTIOM CHECKLIST FOR RESIDENTIAL BUILDING PERMITS PROPERTY LEGAL' Lc S 'F~oL,L -5- (c (Iq SR PROPERTY ADDRESS: ~l _ I N ( /l.9 ~4} INSPECTOR: .,a~~e-d'tUwe ~ ?`~~~k Den;e4so'I WSPECTION DATE: ayi o ¢ Z/ Z. SITE GRADING ? o Ali slopes 3:1 or flatter? 19~ Slopes steeper than 3:1 require retaining wall. Are retaining walis present? ? Does grading conform to As-Built Grading Plan 1 foot approximately)? 11~//o ? Does perimeter grading tie in well with adjacent properties/undisturbed land? gD ? Is there proper grading and/or drainage around Lookout or Egress Windows? EROSION CONTROL vo ? Is Silt Fence (or approved equal) installed and in good working order? ~ Is Sod/Fiber Blanketinstalled hehind curb? Is the Rock Construction Entrance/Driveway installed and in good working order (proper typelsize of aggregate, clean-not covered with soil, etc.)? 10 Is temporary vegetative cover w/ mulch present? Is permanent vegetative cover wl or w/o mulch present? (circle one) CITY EASEMENTS AND UTILITIES ~0 ? Are all easements clear-no part of any building/deck/porch/retaining walVetc. encroaching in easement? ? Are catch basins present within the property or in the street in front of the property, if so . / are they clean, do they have the proper erosion control in and/or around them? g~ ? Does the property have an Emergency Over Flow (EOF)? This can be found on the Certificate of Survey. If so, is it present and has it been graded properly? MISCELLANEOUS ITEMS ?~7 ? Is there tracking present on Public Right-of-Way/Street from construction site? 10/ Is the driveway at the proper width at ROW line? (22 ft. max.)(Curb stop is at ROW line) ? Is the site clean, no trash and/or construction debris lying around? ? Was the proper type of building constructed according to the approved grading plans? . (LO, WO, FB, R, etc.) Address:1478 Wellington Way Zip: 55122 ~ 76656 THE FOLLOWIIVG ITEMS WERE/WERE NOT COMPLETE AT FINAL INSPECTION ON : I~ J~( J D C Yes No Comments Final grade - 6" from siding Permanent ste s- ara e Permanent ste s- main ent Permanent drivewa Permanent as Retainin Wall or 3:1 Max Slo e SodlSeeded lawn TraiUcurb damage Porch Lower level finish Deck Fire lace • Verify with your builder that roof test caps from the plum6ing system have been removed. . Turn offwater supply to the outside lawn faucets before freeze potential exists. • Call the Ciry's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. V BUILDINC IlVSPECTOR: GBldg Insp/Forms/2007/Checklists Orr~el- 7-07