Loading...
3130 Lexington Ave - ADA Surveyy. SEBEJTA BLOMBLRC? ADA SURVEY OF 3M EAGAN FACILITY Date: March 12, 2007 To: Mr. Roger Counihan, Engineering Technology Manager, Corporate Services Engineering, 3M Corporation From: Drew Bjorklund, Senior Architect, Sebesta Blomberg Project: 3M, Cottage Grove Center Sebesta Blomberg Project No. 102709.00 Survey Date: March 6, 2007 Intent of Survey: To verify current status of compliance with the Minnesota Accessibility Code. Survey focused on the following elements; site access, building access, toilet rooms, cafeteria and common areas. The survey did not delve into office cubicles and office spaces; it is assumed that if the need arises, accommodations could be made quickly to adapt these spaces in accordance with accessibility standards. Manufacturin (F-1) 78,960 SF Office (B) 23,290 SF Warehousin O 8-1) 20,585 SF Manufacturin (F-1 790 Office B) 232 Warehousin (S-1) 41 Building Statistics Site Access Notes: The main entrance is located on the north side of the facility. The main parking lot, which contains the dedicated accessible parking spaces is also located on the north side of the building. There are seven (7) parking stalls that are denoted to be accessible, with both pole signs and pavement markings. These stalls are closest to the accessible walkway> which leads up to the main entrance. The accessible walkway has a slope of approximately 1:23. The walk has no railings. It does terminate at the parking lot pavement with a compliant curb ramp. ADA Survey for 3M Eagan FaciliN Sebesta Blomberg Project No. 102709A0 March 6, 2007 Page 1 of5 SEBESI-A BL0MBERG ADA SURVEY OF 3M EAGAN FACILITY Site Statistics: No(es General parking 281 316 Parking provided exceeds required parking space count. Accessible 8 7 Need to add one accessible stall. One stall must be van accessible and have a minimum 8' wide aisle. Signage for van accessible space must be provided. Accessible spaces need to be re-striped to re-define aisles between arkin stalls. Building Access and Functional Areas: As stated above, the main entrance is accessed by an accessible walk and by stairs. This is a secured entrance, with a card reader inside the vestibule. The exterior door leaves are each 36" wide. The interior set of door leaves are 35" wide. Both sets of doors provide the minimum 32" wide opening in accordance with the ADA and Minnesota SBC. The distance between the sets of doors is 8'-6", which exceeds the required distance between doors in sequence. Once inside, virtually any function performed within the plant is either accessible or accommodations could be readily made to provide for universal access. The survey did not search for accessible office spaces (fixed or cubicles), but it is assumed that if spaces needed to be made accessible, this could be achieved. The survey concentrated on common use areas, such as corridors, toilet facilities, cafeteria and dining area. There are no shower areas within the plant. Corridors and aisles are generally compliant, being at least 36" in width. Most of the aisles and corridors range from 6' to 10' wide throughout the office and plant areas. Accessibility signage at toilet rooms B141 and B142 should be removed, since this set of toilet rooms is not accessible. These toilet rooms were measured and found to be out of compliance with the MN Accessibility Code, as were CI04C, C108A, C110. Plumbing Fixture Requirements: ADA Survey for 3M Eagan Facility March 6, 2007 Sebesta Blomberg Projcct No. 102709.00 Page 2 of 5 Comparison of required fixtures and provided fixtures is as follows*: SEBtsrn B Lt)!vl [i E EiG ADA SURVEY OF 3M EAGAN FACILITY t 20 + 10 Urinals 24 3+ several bottied water stations Total universally accessible 2 2 3 re aired - 5% Total universally accessible 4 5 2 provided (Exceeds (Exceeds (Add one and repair re uirements) re uirements) other - see below) *List covers a!l toilet rooms within the faciliry, including- A116, A117A, B141, B142, C704C, C708A, CI10, D106A, D107A, E1 SSS. Specific common-use areas are assessed far universal accessibility as follows: Space ocatio Toilet Room D106A Accessible W/C No Move entrance wall of stall to provide minimum 48" from lip of W/C to front wall Accessible urinal Yes Accessible lav Yes - nominally Bottom of front apron is 28-3/4" from floor. Plumbing is protected and dimensionall com liant. Towel dis enser Yes Towel dis osal Yes Soa dis enser Yes Mirror Yes Grab bars Yes - nominally Vertical grab bar missing. Side horizontal grab bar is 10" from back wall, vs standard 12". Toilet a r dis enser No Mount below harizontal rab bar. Toilet Room D107A Accessible W/C No Move entrance wall of stall to provide minimum 48° from lip of W/C to front wall. Centerline of W/C is a roximatel 17" from side wall. Accessible lav Yes - nominally Bottom of front apron is 28-3/4" from floor. Plumbing is protected and dimensionall com liant. Towel dis enser Yes Towel dis osal Yes Soa dis enser Yes Mirror Yes Grab bars Yes - nominally Vertical grab bazmissing. Side horizontal grab bar is 10" from back wall, vs standard 12". ADA Survey for 3M Eagan Faciliry March 6, 2007 Sebesta Blomberg Project No. 102709.00 Page 3 of 5 SEBESTA BLOMBERG ADA SURVEY OF 3M EAGAN FACILITY Toilet a er dis enser No Mount below horizontal rab bar. Toilet Room A116 Accessible W/C Yes Accessible urinal Yes Accessible lav Yes Towel dis enser Yes Towel dis osal Yes Soa dis enser Yes Mirror No Bottom of mirror and shelf to be moved down to 40" AFF. Grab bars Yes Toilet paper dispenser No Mounted too far from front of toilet. Should be mounted 7" to 9" from lip of toilet. Access to Cloak Room No 18" Clearance on pull-side of jamb is not provided. Universal access to space can be gained from Passage A 165A. Toilet Room A117A Accessible W/C Yes Accessible lav Yes Towel dis enser Yes Towel dis osal Yes Soa dis enser Yes Mirror No Bottom of mircor and shelf to be moved down to 40" AFF. Grab bars Yes Toilet paper dispenser No Mounted too far from front of toilet. Should be mounted 7" to 9" from lip of toilet. Cafeteria Room A172 Tables Yes Counter No Provide portion of counter that is between 28" and 34" hi h. Sink No Provide wheel chair pull-in space and sink at counter that is between 28" and 34" hi h. Vendin area Yes Servin line Yes Door to atio Yes Patio tables No Provide wheel chair access to 1 or more tables. Unisex Toilet E155S Accessible W/C No Space between lip of toilet and lav is 45°. Accessible urinal No Space between urinal and lip of toilet is 45". ADA Survey f'or 3M Eagan Facility Sebesta Blomherg Projec[ No. 102709.00 March 6, 2007 Page 4 of 5 i? 5EI3ESTA BLUMBERG ADA SURVEY OF 3M EAGAN FACILTTY Accessible lav Yes - nominall o Below sink i in is not covered. Towel dis enser Yes Towel disposal Yes - nominally Waste basket infringes on clear floor s ace. Su est wall-mounted model. Soa dis enser Yes Mirror Yes Grab bars Yes - nominally Vertical grab bar is mounted slightly too hi h. Toilet a er dis enser Yes General Office Area Drinking fountain ai 5141/B742 Yes - nominally Compliant but not working. Manufacturing Area D Drinking fountain at D 106A / D 107A Yes Lab Area, Area A Drinking fountain at Corridor A145 No Fountain mounted too high. Survey Conducted and Reported by: Drew C. Bjorklund, AIA, CSI Senior Architect Sebesta Blomberg and Associates, Inc. ADA Survey for 3M Eagan Facility Sebesta Blomberg ProjectNo. 102709.00 March 6, 2007 Page 5 of 5