Loading...
2248 Wall St - Energy Code CompliancePer NI101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI101.8. Date Certificate Posted 5/28/10 nnehjem Itte BMOC CORPORATION -- Mailing Address of the Dwelling or Dwelling Unit 2248 Wall Street REVISED - ED 5/28/10 ity Eagan, MN Name of Residential Contractor Solar Heat Gain Coefficient (SHGC): " "N License Number 20108964 Vennehjem Building Corp. THERMAL ENVELOPE RADON SYSTEM Insulation Location Total R -Value of all Types of Insulation Type: Check All That Apply X Passive (No Fan) Non or Not Applicable Fiberglass, Blown Fiberglass, Batts Foam, Closed Cell Foam Open Cell Mineral Fiberboard Rigid, Extruded Polystyrene Rigid, Isocynurate Passive Active (With fan and monometer or other system monitoring device) Other Please Describe Here Below Entire Slab Lennox X Powered Model G61- MP -60C -091 82V52 -2 XC13- 042 -230 Interlocked with exhaust device. Describe: Rating or Size Foundation Wall R10 Capacity in Gallons: 50 Output in Tons: 3.5 Other, describe: Structure's Calculated X Interior Perimeter of Slab on Grade Heat Gain: X Location of duct or system: Efficiency AFUE or HSPF% 95 SEER: 13 Calculated cooling load: Rim Joist (Foundation) R13.4 Clm's X Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back -up furnace): Select Type " metal duct Combustion Air Select a Type Interior Rim Joist (1 Floor +) R13.4 Passive X Heat Recover Ventilator (HRV) Capacity in cfms: X 170 High: 214 Interior Wall R19 Low: X Location of duct or system: Continuous exhausting fan(s) rated capacity in cfms: Location of fan(s), describe: I Ceiling, flat R44 Capacity continuous ventilation rate in cfms: X " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct Ceiling, vaulted R38 X Bay Windows or cantilevered areas X Bonus room over garage R40 X X 2" sprayed foam + R30 Batt Insulation Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U- Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.32 X R -value 8.0 MECHANICAL SYSTEMS I Make - up Air Select aType Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Natural Gas Electric Electric Passive Manufacturer Lennox Rheem Lennox Powered Model G61- MP -60C -091 82V52 -2 XC13- 042 -230 Interlocked with exhaust device. Describe: Rating or Size Input in BTUS: 88,000 Capacity in Gallons: 50 Output in Tons: 3.5 Other, describe: Structure's Calculated Heat Loss: 77520 Heat Gain: 33989 Location of duct or system: Efficiency AFUE or HSPF% 95 SEER: 13 Calculated cooling load: 33989 BTU Clm's " round duct OR Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back -up furnace): Select Type " metal duct Combustion Air Select a Type X Not required per mech. code Passive X Heat Recover Ventilator (HRV) Capacity in cfms: Low: 170 High: 214 Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfms: Location of fan(s), describe: I Cfm's Capacity continuous ventilation rate in cfms: " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct �T •� � r 9,2 45i New Construction Energy Code Compliance Certificate ROOM NAME Area (ft Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room 1 1242 10099 4672 483 519 level3 1540 20181 8047 964 894 level2 1242 15761 7079 753 787 Entire House 4024 46041 19797 2200 2200 Other equip loads 31479 5045 Equip. @ 0.93 RSM 23054 Latent cooling 10935 T/1TAI , AA/1A "77 C•1A�/ / •i/ 'I7 AA nn nn p/ A- 44, �,� <6 ( 4 wrightsoft' Load Short Form Entire House -7 � go co a l l SI-. Project Information Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat For. Outside db ( °F) Inside db ( °F) Design TD ( °F) Daily range Inside humidity ( %) 40 Moisture difference (gr/lb) 51 HEATING EQUIPMENT Make Lennox Trade Signature Model G61- MP -60C -091 GAMA ID .. -*- wrightsoft• Sanchez res., Vennehjem Building Corp 4200 County Road 42, Burnsville, mn 55137 Design Information Htg -/5 75 90 Clg 88 70 18 M 40 50 95 AFUE 88000 Btuh 82000 Btuh 35 °F 2200 cfm 0.048 cfm/Btuh 0 in H2O Method Construction quality Fireplaces 33989 Right Suite® Universal 7.1.17 RSU10932 AW:lk C: \Documents and Settings \admin \My Documents \Wrightsoft HVAC \vemehjem building corp.rup Calc = M Infiltration COOLING EQUIPMENT Make Lennox Trade Signoture Cond XC13 -042 -230 Coil C33 -36C -2 ARI ref no. Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ob: Sanchez Date: Itanbing a... Simplified Tight 1 (Average) 12.0 EER, 13 SEER 35245 0 35245 2200 0.111 0 0.69 Btuh Btuh Btuh cfm cfm /Btuh in H2O 2010- May-27 17:18:34 Page 1 Component Btuh/ft Btuh % of load Walls 0.7 2529 10.2 Glazing 21.1 6993 28.1 Doors 11.0 926 3.7 Ceilings 1.7 2842 11.4 Floors 0 0 0 Infiltration 0.1 297 1.2 Ducts 0 0 Ventilation 3339 13.4 Internal gains 6210 25.0 Blower 1707 6.9 Adjustments 0 Total 24842 100.0 Component Btuh/ft Btuh % of load Walls 6.0 21823 28.2 Glazing 27.0 8937 11.5 Doors 33.1 2778 3.6 Ceilings 2.9 4781 6.2 Floors 1.7 2800 3.6 Infiltration 2.1 4922 6.3 Ducts 0 0 Piping 0 0 Humidification 14596 18.8 Ventilation 16882 21.8 Adjustments 0 Total 77520 100.0 -4- wrightsoft® Building Analysis Entire House Pro - ect Information For. Sanchez res., Vennehjem Building Corp 4200 County Road 42, Burnsville, mn 55137 Desi • n Conditions Location : Minneapolis /St. Paul, MN, US Elevation: 837 ft Latitude: 45°N Outdoor: Dry bulb ( °F) Daily range (°F) Wet bulb (°F) Wind speed (mph) Heat1 Cooling 79 (M ) 15.0 7.5 Latent Cooling Load = 10935 Btuh Overall U -value = 0.057 Btuh/ft - °F Data entries checked. Bold/italic values have been manually overridden AL-- -41- wriyhtsfolrt" Right - Suite® Universal 7.1.17 RSU10932 C:\Documents and Settings \admin\My Documents \Wrightsoft HVAC \vemehjem building corp.rup Calc = M Indoor: Heating Indoor temperature ( °F) 75 Design TD ( °F) 90 Relative humidity ( %) 40 Moisture difference (gr /lb) 51.4 Infi ltration: Method Construction quality Fireplaces Heatin• Glazing umi°ification WoHa. Doors 7_ r ` Infiltration Ceilings Floors Coolin• Job: Sanchez Date: May 27, 2010 By: Farmington Plumbing a... Simplified Tight 1 (Average) Ventilation Cooling 18 40 50.4 2010- May-27 17:09:13 Page 1 4 wrightsoft® Component Constructions Entire House Project Information For. Design Conditions Location: Minneapolis /St. Paul, MN, US Elevation: 837 ft Latitude: 45 °N Outdoor: Dry bulb ( °F) Daily range ( °F) Wet bulb ( °F) Wind speed (mph) Construction descriptions Walls Partitions (none) Doors 11 JO: Door, mtl fbrgl type 11 P0: Door, mtl pur core type Sanchez res., Vennehjem Building Corp 4200 County Road 42, Burnsville, mn 55137 Heating -15 15.0 Cooling 88 19 (M ) 72 7.5 15B- losfc-2: Bg wall, light dry soil, concrete wall, r -10 ins, 8" thk 15B11 -8wo-8: Bg wall, light dry soil, 2 "x4" wood int frm, concrete wall, r -10 ins, 8" thk 12E -Osw. Frm wall, vnl ext, 1/2" wood shth, r -19 cav ins, 1/2 gypsum board int fnsh, 2 "x6" wood frm Windows 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/4" thk: 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/4" thk Indoor: Heating Indoor temperature ( °F) 75 Design TD ( °F) 90 Relative humidity ( %) 40 Moisture difference (gr /lb) 51.4 Infiltration: Method Construction quality Fireplaces Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft' Btih/t' -°F fe- °FBtuh Btuh/Bt e s w all n e s w all w n n e e s w w all n e s w all 556 0.061 10.0 650 0.061 10.0 590 0.061 10.0 625 0.061 10.0 2421 0.061 10.0 297 0.041 19.0 339 0.041 19.0 297 0.041 19.0 27 0.041 19.0 960 0.041 19.0 272 0.068 19.0 -141- wrightsoft- Right Suite® Universal 7.1.17 RSU10932 C:\Documents and Settings \admin \My Documents \Wrightsoft FIVAC \vemehjem buildirg corp.rup Calc = M Job: Sanchez Date: May 27, 2010 By: Farmington Plumbing a... Simplified Tight 1 (Average) Cooling 70 18 40 50.4 Btuh BtihRN Btuh 6.84 3801 0.84 468 6.96 4526 0.92 598 6.87 4054 0.86 510 6.94 4341 0.91 567 6.91 16721 0.88 2143 3.69 1096 0 0 3.61 1224 0 0 3.69 1096 0 0 0.77 20 0 0 3.58 3437 0 0 6.12 1665 1.42 387 4 0.280 0 25.2 101 11.0 44 130 0.300 0 27.0 3513 11.4 1480 4 0.280 0 25.2 101 34.8 139 12 0.300 0 27.0 324 35.2 422 100 0.300 0 27.0 2704 20.2 2024 41 0.300 0 27.0 1102 35.2 1436 41 0.300 0 27.0 1094 35.2 1425 332 0.3 0 27.0 8937 21.0 6971 21 0.600 6.3 54.0 1134 18.0 378 21 0.290 10.5 26.1 548 8.70 183 21 0.290 10.5 26.1 548 8.70 183 21 0.290 10.5 26.1 548 8.70 183 63 0.290 10.5 26.1 1644 8.70 548 2010- May-27 17:09:13 Page 1 ' Ceilings 16 30ad: Attic ceiling, asphalt shingles roof mat, r -20 roof ins, r -30 1660 0.032 30.0 2.88 4781 1.71 2842 ceil ins Floors 21A -32t: Bg floor, light dry soil 1242 0.020 0 1.80 2236 0 0 21B -28t: Bg floor, light dry soil, prm int ins coy, r -3 ins, tile flr fnsh 418 0.015 3.0 1.35 564 0 0 ,.� wrightsaft- Right - Suite® Universal 7.1.17 RSU10932 C: \Documents and Settings \admin \My Documents \Wrightsoft HVAC \vemehjem building corp.rup Calc = M 2010- May-27 17:09:13 Page 2 - wrightsoft® Project Summary Entire House Project Information Outside db Inside db Design TD Structure Ducts Central vent (234 cfm) Humidification Piping Equipment load Method Construction quality Fireplaces Area (ft Volume (ft Air changes /hour Equiv. AVF (cfm) Heating Equipment Summary Make Lennox Trade Signature Model G61- MP -60C -091 GAMA ID Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat For. Notes: Heating Summary Infiltration Sanchez res., Vennehjem Building Corp 4200 County Road 42, Burnsville, mn 55137 Desi • n Information Winter Design Conditions -15 °F 75 °F 90 °F Weather: Minneapolis /St. Paul, MN, US 46041 Btuh 0 Btuh 16882 Btuh 14596 Btuh 0 Btuh 77520 Btuh Simplified Tight 1 (Average) Heating Cooling 4024 4024 18749 18749 0.16 0.05 51 16 95 AFUE 88000 Btuh 820 Btuh 2200 cfm 0.048 cfm/Btuh 0 in H2O Outside db Inside db Design TD Daily range Relative humidity Moisture difference Job: Sanchez Date: May 27, 2010 By: Farmington Plumbing a... Summer Design Conditions 88 °F 70 °F 18 °F M 40 % 50 gr/lb Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (234 cfm) Blower Structure Ducts Central vent (234 cfm) Equipment latent load Equipment total load Req. total capacity at 0.00 SHR Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 19797 Btuh 0 Btuh 3339 Btuh 1707 Btuh Use manufacturer's data n Rate/swing multiplier 0.93 Equipment sensible load 23054 Btuh Latent Cooling Equipment Load Sizing 3140 Btuh 0 Btuh 7796 Btuh 10935 Btuh 33989 Btuh 2.7 ton Cooling Equipment Summary Make Lennox Trade Signoture Cond XC13 -042 -230 Coil C33 -36C -2 ARI ref no. Efficiency 12.0 EER, 13 SEER Sensible cooling 0 Latent cooling 35245 Total cooling 35245 Actual air flow 2200 Air flow factor 0.111 Static pressure 0 Load sensible heat ratio 0.69 Btuh Btuh Btuh cfm cfm /Btuh in H2O -4i- wrllghtarott- Right - Suite® Universal 7.1.17 RSU10932 2010-May-27 17:09:13 /IC.C.P1/4 C:\Documents and Settings \admin \My Documents\Wrightsoft HVAC \vemehjem building corp.rup Calc = M Page 1 - wrightsoft° AED Assessment Entire House Pro'ect Information For Sanchez res., Vennehjem Building Corp 4200 County Road 42, Burnsville, mn 55137 Design Conditions Location: Minneapolis /St. Paul, MN, US Elevation: 837 ft Latitude: 45 °N Outdoor: Dry bulb ( °F) Daily range ( °F) Wet bulb ( °F) Wind speed (mph) 11,000 — 10,000 - 9,000- 8,000- 7,000- 6,000- 5,000- 4,000 3,000 - 2,000- 1,000- 0 8 9 / Hourly Heating -15 15.0 Indoor: Heating Indoor temperature ( °F) 75 Design TD ( °F) 90 Relative humidity ( %) 40 Cooling Moisture difference (gr /lb) 51.4 88 Infiltration: 19 (M ) 72 7.5 Test for Adequate Exposure Diversi Hourly Glazing Load 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Average Maximum hourly glazing load exceeds average by 30.3 %. House does not have adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 22 Btuh (PFG - 1.3*AFG) Bold/italic values have been manually overridden I AED Ym5 �'►�y - t wrightsof t° Right Suite® Universal 7.1.17 RSU10932 AGC,A C: \Documents and Settings \admin \My Documents \Wrightsoft FNAC \vemehjem building corp.rup Calc = M Job: Sanchez Date: May 27, 2010 By: Farmington Plumbing a... Cooling 70 18 40 50.4 2010- May-27 17:09:13 Page 1 wrightsoft Right -J® Worksheet Entire House Job: Sanchez Date: May 27, 2010 By: Farmington Plumbing and ... 1 2 3 4 5 6 11 6 12 13 14 15 Room name Exposed wall Ceiling height Room dimensions Room area Ty Construction number 15B- 10Sfo. 2 glazing,; d r outr,. 2 11,10 a � t r out 15B11 -8wc -8 15B- 10afx.2 2 glazing, dr out 2 glazing, dr outr, 15 B 11 -8wc -8 11 PO 15B- 10sfo-2 2 glazing, dr out PO 15B11 -6wc -8 12E-Osw 15 B- 10sfo•2 2 glazing, clr outr, 15811 -8!8 2 glaz2 glaitrtig, dr nut, 11 PO 16B -30ad 21 A-32t 21 B -28t U -value Or (Btu h/ft F) 0.300 . r 0.600 n 0.055 n 0.083 e 0.200 e 0.300= e. 0.055 e 0.290 e 0.083 s .300 s 1290 s 0.055 s 0.068 w 0. 083 w 0.300 w 0.055 0.300 0.290 0032 0.020 - 0. 015 - HTM (Btuh/ft') Heat 3.69 3.61 26.10 6.87 27.00 26.10 3.69 6.12 6.94 27.00 0.77 27.00 26.10 2.88 1.80 1.35 Cool 0.00 0.92 34.83 5.19 0.00 8.70 0.86 0.21 .70 0.00 1.42 0.91 35.19 0.00 35.19 8.711 1.71 0.00 0.00 c) AED excursion Envelope loss/gain a) Infiltration b) Room ventilation Internal gains: Occupants (a) 230 Appliances/other Subtotal (lines 6 to 13) Less edema) load Less transfer Redistribution Subtotal Duct loads Total room load Air required (cfm) 8.0 ft 4024.0 fP Entire House 452.0 ft Area fF) or perimeter (ft) Gross 297 666 4 12 360 21 711 100 21 297 272 666 41 as 41 21 1660 1242 418 13 0% N /P /S 556 0 0 21 297 650 0 0 339 21 590 0 21 0% Load (Btu h) Heat 3801 3513! 1134 1096 4526 324 1224 548 4054 2704 548 1096 1665 4341 41119 4922 0 46041 0 0 0 46041 0 46041 2200 Cool 183 510 2024 183 0 387 567 1436 0 1425 183 2842 a 0 22 13290 297 0 2990 3220 19797 0 0 0 19797 0 19797 2200 Room1 146.0 ft 8.0 ft heat/cool 1.0 x 1242.0 ft 1242.0 fF Area ff) or perimeter (ft) (Btu h) Load Gross 360 21 0 0 0 ' 3 0% N/P /S Heat 0 339 21 ;0 0 0 1096_ 0 0 1224 548 0 0 0 0 297 1096 272 1665 0 0 0 0 20 3 9527 573 0 10099 0% 0 0 0 10099 0 10099 483 Cool 183 0 0 0 0 117 550 2727 35 0 690 1220 4672 0 0 0 4672 0 4672 519 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrapr.saore- Right - Suite® Universal 7.1.17 RSU10932 P. C: \Documents and Settings \admin \My Documents \Wrightsoft HVAC \vemehjem building corp.rup Calc = M 2010- May-27 17:09:14 Page 1 wrightsoft Right -J® Worksheet Entire House Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ►. -f4 we-sco tsore- Right - Suite® Universal 7.1.17 ACCK C: \Documents and Settings\admin \My Documents \Wrightsoft HVAC \vemehjem building corp.rup Calc = M Job: Sanchez Date: May 27, 2010 By: Farmington Plumbing and ... 1 2 3 4 5 6 11 6 12 13 14 15 Room name Exposed wall Ceiling height Room dimensions Room area Ty Construction number 158 2 gl 11,JJ0 rk. 15B1 1 -8wc -8 15B -1062 2 glazing, dr out 2 glazing, dr € ut, 15 B 11 -8wc -8 11 PO 15B-IOsfo-2 2 11 POD, dr outr, 15811 -8wc -8 12E -Osw' 15B- 10sfo-2 2 glazing, clr out 15B11 -£!8 22gl O irk dr outt, 16 B-30ad 21A -32t: 21 B -28t U -value (Btuhfft 0.055 0.0 83 0.280 0.300 0.055 0.290 0.083° 0.300 0.290 0.055 0.088 0.083 0.300 0.055 0.300 0.290 0.032 0.020 0.015 Or n e e! e e s s S '.. S w w w w w w' HTM (Btuh/ft Heat 3.61 26.10 6,87 27.00 26.10 3.69 6.12 6.94 27.00 0.77 7. 00 6 .10 2.88 1.80 1.35 Cool 0.84 11.02 11.38 18..00 0.00 0,92 34.83 35.19" 0.00 8.70 0.86 20.21 8.70 0.00 1,42 0.91 35.19 0.00' 35.19 8.70 1.71 0.00 0.00 c) AED excursion Envelope loss/gain a) Infiltration b) Room ventilation Internal gains: Occupants @ 230 Appliances/other Subtotal (lines 6 to 13) Less extemal load Less transfer Redistribution Subtotal Duct loads Total room load Air required (cfm) leeel3 160.0 ft 8.0 ft heat/cool 1.0 x 1540.0 ft 1540.0 ft Area ft or perimeter (ft) Gross 0 0 414 58 0 0 0 306 29 0 1540 0 418 5 0% N/P /S 9 0 0 0 0 290 0 0' 0 0 356 0 0 0 0 277 0 0 0 0 1540 418 0% Load (Btu h) Heat 2553' 101 1102 0' 0 15 OI 24 0 0 2456 1559 0 0 0' 17907 2274 0 20181 0 0 0 20181 0 20181 964 Cool 329 44 464 0 0 264 139 422 0 0 313 1167 0 0 0 248 -281 6760 137 0 1150 0 8047 0 0 0 8047 0 8047 894 leeel2 146.0 ft 8.0 ft heat/cool 1.0 x 1242.0 ft 1242.0 ft Area ft or perimeter (ft) Gross 5 0% N/P /S 0 0 348 0 0% Load (Btu h) Heat Cool 0 0 0 0 2421 324 0 1016; 0 4 0 0 0 0 197 857 183 0 0 319 422 2 0 346 205 O 0 0 -247 13686 3803 2075 125 O 0 1150 2000 15761 7079 O 0 O 0 O 0 15761 7079 O 0 15761 7079 753 787 2010- May-27 17:09:14 Page 2