4900 Biscayne Ave - Ltr re Voigt & Assoc Structural EngrsWednesday, July 07, 2010
RE: 4900 Biscayne, Resemomn 14,0444.14111 .
Dear Mr. Kevin Manley:
As per your request I made a site visit to the aforementioned addresses. The purpose of the site visit was to evaluate the great room
walls. In addition I reviewed the detail and letters that were produced by our office on 10- 21 -09.
Observations:
While the framing arrangement is different than we had detailed the tallest part of the wall is framed with a higher grade material than
we originally specified. Connecting hardware was not installed.
Remedial Work Required:
1. At headers install Simpson A35 framing angle at each end of header, one per end (i.e. exterior sheathing does not need to be
removed.
2. At king studs install USP A3TZ (A23Z) framing angle top and bottom each side on intermediate king studs and one side only
on the king studs that form the outer most mullion on the window sets.
The information and opinions contained herein are based upon the limited investigation described at the beginning of this
report. No warranties are expressed or implied regarding the existence of other unknown conditions not specifically
addressed. Our work is in accordance with generally accepted engineering standards and is not intended to be relied upon
or transferred to individuals other than the addressee. Should information or conditions become known which differ from
the discussion herein, they may alter the opinions or conclusions of the undersigned. Please call if you have any
questions.
Sincerely,
P o.Q. w. v —
Paul W. Voigt, P.E.
Voigt & Associates, Inc.
I - STRUCTURAL ENGINEERING SERVICES
4635 NICOLS RD. SUITE 204
- EAGAN, MN 55122
PH. (651) 686 -7727 FAX. (651) 686 -8444
I Hereby Certify That This Plan, Specification, Or Report Was Prepared
By Me Or Under My Direct Supervision And That I Am A Duly
Licensed Engineer Under The Laws Of The State Of Minnesota.
A4. IAA
Paul W. Voigt
Date 7/7/2010