4900 Biscayne Ave - Ltr re Voigt & Assoc Structural EngrsWednesday, July 07, 2010 RE: 4900 Biscayne, Resemomn 14,0444.14111 . Dear Mr. Kevin Manley: As per your request I made a site visit to the aforementioned addresses. The purpose of the site visit was to evaluate the great room walls. In addition I reviewed the detail and letters that were produced by our office on 10- 21 -09. Observations: While the framing arrangement is different than we had detailed the tallest part of the wall is framed with a higher grade material than we originally specified. Connecting hardware was not installed. Remedial Work Required: 1. At headers install Simpson A35 framing angle at each end of header, one per end (i.e. exterior sheathing does not need to be removed. 2. At king studs install USP A3TZ (A23Z) framing angle top and bottom each side on intermediate king studs and one side only on the king studs that form the outer most mullion on the window sets. The information and opinions contained herein are based upon the limited investigation described at the beginning of this report. No warranties are expressed or implied regarding the existence of other unknown conditions not specifically addressed. Our work is in accordance with generally accepted engineering standards and is not intended to be relied upon or transferred to individuals other than the addressee. Should information or conditions become known which differ from the discussion herein, they may alter the opinions or conclusions of the undersigned. Please call if you have any questions. Sincerely, P o.Q. w. v — Paul W. Voigt, P.E. Voigt & Associates, Inc. I - STRUCTURAL ENGINEERING SERVICES 4635 NICOLS RD. SUITE 204 - EAGAN, MN 55122 PH. (651) 686 -7727 FAX. (651) 686 -8444 I Hereby Certify That This Plan, Specification, Or Report Was Prepared By Me Or Under My Direct Supervision And That I Am A Duly Licensed Engineer Under The Laws Of The State Of Minnesota. A4. IAA Paul W. Voigt Date 7/7/2010 License Number 20705