Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
3607 Springwood Ct
r City of Eaau 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675.5675 Fax: (651) 675-5694 Use BLUE or BLACK Ink V' l Tart; H Permit #: C% CC Permit Fee: 1, 7 4 • 76 Date Received: Staff: 1 2010 RESIDENTIAL BUILDING PERMIT APPLICATION Date: - it2/7, /E? Site Address: Tenant: ANN, ' [ 7i p, RESIDENT / OWNER 36a7 Jipiti wail Name: L te'LINA& Phone: Address / City / Zip: . Suite #: Applicant is: Owner Contractor TYPE OF WORK CONTRACTOR Description of work: Construction Cost: r sty. tgAs:e. Name: /0'2/7 L9` -_-- Address: Multi -Family Building: (Yes / No"( ) State: Zip: Phone: Contact: Email: License #: City: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? r -_Yes )(No If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Phone: Phone: Sewer & Water Contractor: Phone: NOTE: Plans and supporting documents that you submit are considered to be public information.y Portions of the information'°maybe classified as non public if you provide. specrflc reasons that would permit the City to conclude that they ar etradesecrets CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.Qopherstateonecail.orq 1 hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with a appro ed plap in the case of work which requires a review and app . . .. . x Applicant's Pri jtoj A 42-1 Appii ants Sature Page 1 of 2 SUB YPES Foundation Single Family Multi 01 of Plex Accessory Building WORK TYPES New Addition x Alteration Replace Retaining Wali DESCRIPTION Valuation Plan Review Fireplace Garage Deck -P,v Lower Level )o DO NOT WRITE BELOW THIS LINE _ Interior Improvement _ Move Building Fire Repair Repair (25% 100% yJ Census Code #of Units # of Buildings Type of Construction REQUIRED INSPECTIONS Footings (New Building) Footings (Deck) Footings (Addition) Foundation Drain Tile Roof: Ice &Water Final T" Framing Fireplace: _Rough In Air Test Insulation Meter Size: Reviewed By: Porch (3 -Season) Porch (4 -Season) Porch (Screen/Gazebo/Pergola) Pool Occupancy Code Edition Zoning Stories Square Feet Length Width Final Siding Reroof Windows Egress Window Storm Damage Exterior Alteration (Single Family) Exterior Alteration (Multi) Miscellaneous _ Demolish Building* _ Demolish Interior Demolish Foundation Water Damage *Demolition of entire building - give PCA handout to applicant MCES System SAC Units City Water Booster Pump PRV Fire Sprinklers Sheetrock Final / C.O. Required Final / No C.O. Required HVAC Other: Pool: Footings _Air/Gas Tests _Final Siding: °Stucco Lath __Stone Lath _Brick Windows Retaining Wall: s Footings _ Backfill Final Radon Control Erosion Control , Building Inspector RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Copies TOTAL lf0 P-66 x G997_�6ys�1,� iyo c_66;, ft sc 75-0, City of Eaali pL. L.5 -n° 3830 Pilot Knob Road E �o — Eagan MN 55122- AUG 0 4 RE ' g qi Phone: (651) 675 5675 �D Fax: (651) 675-5694 Use BLUE or BLACK Ink Permit#: Permit Fee: Y Date Received: Staff: 2010 RESIDENTIAL BUILDING PERMIT APPLICATION Date: Y( -a0 Site Address: 960/ S aria ( re, c Tenant: 1-0r L, D L4!, , Suite #: RESIDENT / OWNER Name: Phone: Address / City / Zip: Applicant is: Owner Contractor TYPE OF WORK Description of work: ® f itct/ , Construction Cost: 8/ 0, 0 0 0 Multi -Family Building: (Yes / NoX) CONTRACTOR Name: Leti'rV OL/ AdiGl i / 1'' License #: iii?_? Address: fir 2 0,44y24,1,4 441 City: 4/Ay2-9144 State: AA/ Zip: i 5.31#77 Phone: (7 sl) 25 7 --Jc%O Contact: ® NA G .1`x'.1% Email: !'d � Cav S'a•-� �atiN�P a t � 4 `! tom/' A) / COh COMPLETE In the last 12nths, has Yes r`Alo If yes, THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING the City of Eagan issued a permit for a similar plan based on a master plan? date and ad ess of master plan: Licensed Plumber: //! ' ...et' 1 h1%.1o t 117 05- 9 •IV Y Phone: (9 Vim: 9'/ �( • eel-) Mechanical Contractor: � Phone: 1 (,,� Sewer & Water Contractor: A r Phone:(s,) -2y6- t!J tx i NOTE: Plans and supporting documents that you submmit are considred to be public information. o ion. s of the information may be classified as non-public, if you provide specific reasons that would permit the Crty to ': conclude that they are trade secrets. . , CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gooherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. x /6)1 IT�Ai l/Ge!:f � x PF Applic: nt's Si at"ure Applicant's inted Name Page 1 of 2 ._.eg.;n7Lococi DO NOT WRITE BELOW THIS LINE SUB TYPES Foundation Fireplace Single Family Garage _ Multi Deck _ 01 of Plex _ Lower Level Accessory Building WORK TYPES 1[ New �7` Addition Alteration Replace Retaining Wall DESCRIPTION Valuation Plan Review (25% 100% y) Census Code #of Units # of Buildings Type of Construction Interior Improvement Move Building Fire Repair Repair 03 Porch (3 -Season) Porch (4 -Season) Porch (Screen/Gazebo/Pergola) Pool Occupancy Code Edition Zoning Stories Square Feet Length Width REQUIRED INSPECTIONS Footings (New Building) Footings (Deck) Footings (Addition) )( Foundation Drain Tile Roof: Ice & Water _Final Framing Fireplace: Rough In )(Air Test Final 7( Insulation Meter Size: Reviewed By: Siding Reroof Storm Damage Exterior Alteration (Single Family) Exterior Alteration (Multi) Miscellaneous Demolish Building* Demolish Interior Windows _ Demolish Foundation Egress Window Water Damage *Demolition of entire building - give PCA handout to applicant MCES System SAC Units City Water Booster Pump PRV Fire Sprinklers 1 1 Sheetrock Final / C.O. Required —S. Final / No C.O. Required HVAC Other: Pool: Footings Air/Gas Tests Final Siding: Stucco Lath >Stone Lath Brick Windows Retaining Wall: Footings _ Backfill Final X Radon Control Erosion Control , Building Inspector RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Copies TOTAL 05‘.. 10004 1 11,S/71,V( pa la ) 2-77 "s- 2I VAC)Li3 Page 2 of 2 oDd Date: 7/30/2010 Revision Date: 7/30/2010 New Construction Site Information Address 1: Address 2: City: County: Application Information Business Name: Elander Mechanical Inc. MN Contractor License #: Contact Person: Todd Office Ph: 952-445-4692 Fax: 952-445-7487 Cell Ph: Address 1: 591 Citation Drive City: Shakopee State: Minnesota Zip Code: 55379 Project #: Lot: Block: Subdivision: House Details Square Feet: 4043 sq. ft. Avg. Ceiling Ht: 8.33 Number of Bedrooms: 5 ft. Ventilation : Exhaust Total Ventilation Capacity : 147 cfm. Minimum Continuous Ventilation :90cfm. Continuous Ventilation Provided: Exhaust: 90 cfm Intermittent ventilation satisfied by OTHER exhuast appliance. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 90,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 90 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 300 Make -Up Air No Make -Up Air Required by Code Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches Applicant Name (print): / raj PiQ/ -. Signature/Date: Code Official (print): Signature/Date: © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1 697 kcip9 cod New Construction Energy Code Compliance Certificate Per NI 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Date Certificate Posted ,/ �.. i v . E A 1 e`lnling or Dwelling , , l A �` Mailing Address of the Dwelling it City ��, Name of Residential Contractor 1 V V� Licins�; THERMAL ENVELOPE RADON SYSTEM Insulation Location Total R -Value of all Types of Insulation Type: Check All That Apply X Passive (No Fan) Active (With fan and monometer m- other system monitoring device ) Non or Not Applicable Fiberglass, Blown, Fiberglass, Batts Foam, Closed Cell Foam Open Cell Mineral Fiberboard Rigid, Extruded Polystyrene Rigid, Isocynurate Other Please Describe Here Below Entire Slab Foundation Wall Type in location: interi.-xterior ,r integral Perimeter of Slab on. Grade Rim Joist (Foundation)®, Type in location: interior exterior Rim Joist (lst Floor+)- _• Type in location: interior exterior - integral Wall Iq Ceiling, flat Ceiling, vaulted 4 Bay Windows or cantilevered areas 06 1 Bonus room over garage tt Kt LS - Describe other insulated areas Windows & Doors % 3 Q Heating or Cooling Ducts Outside Conditioned Spaces Average U -Factor xxcludes skylights and one door ) U: • -' S Not applicable, all ducts located in conditioned space R -value Solar Heat Gain Coefficient (SHGC): „ MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System 4 Not required per mech. code Fuel Type . lift' . (. (e J fl • Y''')gmk i L Passive Manufacturer LeANAtht Avian," Umf O)f Powered Model Cittl ---'t t (. ort0 4'VIis-D 0 13rt-co -UY2--2756 Interlocked with exhaust device. Describe: ,._ or Size Input in BTUS: (64 i(,)00Rating Capacity in Gallons: , V Output in, Tons: ++ 3 n% I- Other, describe: „A mc Structure's Calculated Heat Loss: % Y . r , Heat Gain: AA,, �'f/( Location D73 of duct or system: ✓ S Efficiency AFUE or HSPF% 47 1 4• SEER: 13 Calculated cooling load: 1111119101 I 01 /4/ Ctin's " round duct OR Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces dr air source heat pump with gas back-up fumace): Select Type " metal duct Combustion Air Select a Type Not required per mech. code A Passive Other, describe: Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: Location of duct or system: /C Continuous exhausting fan(s) rated capacity in cfms: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms: CI® G tl " round duct OR Total ventilation (intermittent + continuous) rate in cfms: t Ls r " metal duct Created by BAM version 052009 ;ro1 �� e-� , AUG s4p�, PLAN REVIEW FOR COMPLIANCE WITH AIRCRAFT NOISE ORDINANCE Submitter: Lennar 935 E. Wayzata Blvd. Wayzata, MN 55391 952-249-3000 Noise Impact Area Airport - MSP International Noise Zone - 4 New Infill Residence is a "COND" use in Noise Zone 4 Plan Reviewed: CP.:7f' • 7/ 4.-1/5444-404-3\ '2,O1 A414(414Ct19 Cr • Information Submitted: Annotated architectural drawings including: Windows: Atrium Swinging Patio Doors: Atrium Entry Doors: Therma Tru Skylights: N/A Compliance with STC Requirements: Average window/wall area for exterior wall: t 6d With this window/wall area ratio and STC 40 walls, windows with an STC 30 can be used to meet the noise reduction requirements; Summary: Other measures including duct bends and caulking are being taken to ensure minimum transmission of noise through the exterior building shell so that the construction should meet the compatibility guidelines. Therefore, the materials and construction as proposed should meet the requirements of the Eagan aircraft noise ordinance. Review Completed (date): • Z • 147 Review Completed by: Tom Tamte Compliance with Procedures to Ensure Adequate Noise Attenuation: Exterior wall construction: LP Smart Board 15/32" sheathing Tyvek wrap 2x6 studs 16" O.C. R-19 batt insulation with 1/2" gypsum board Roof Construction: Peaked roof with manufactured trusses 24" O.C. Roof vents Shingles 15# felt 1/2" sheathing Blown insulation R-44 5/8" gypsum board Mechanical Ventilation System: 3 -ton central air conditioning unit Window, Door Frame, Perimeter and Other Seals: All window and door openings are to be caulked with butyl -based caulk Fireplace Chimney Cap: Built-in flue damper, chimney cap, glass enclosed Ventilation Duct Exterior Wall Penetrations: All exterior ducts will have bends as required by the ordinance Door and Window Construction: Windows: Atrium (30 STC) Sliding Patio Doors: Atrium (30 STC) Entry Doors: Therma Tru (29 STC) Skylights: N/A Other Exterior Wall Penetrations: Sill sealer between plates and blocks -- wrightsoft Load Short Form Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott Project information For: Design Information Outside db (°F) Inside db (°F) Design TD (°F) Daily range Inside humidity (%) Moisture difference (gr/lb) Htg -16 70 86 50 55 Clg 88 72 16 M 50 33 Method Construction quality Fireplaces Infiltration Simplified Semi -tight 1 (Semi -tight) Make Trade Model HEATING EQUIPMENT Lennox Merit 90 G43 -48C-090-** Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 88000 Btuh 83000 Btuh 50 °F 1556 cfm 0.024 cfm/Btuh 0.00 in H2O COOLING EQUIPMENT Make Lennox Trade 13ACX Series - RFC Cond 13ACX-042-230-* Coil C33-43*+TDR Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13 SEER 29050 Btuh 12450 Btuh 41500 Btuh 1383 cfm 0.067 cfm/Btuh 0.00 in H2O 0.83 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Basement 1536 13070 409 317 27 Study 168 3452 1448 84 97 3/4 Bath 54 2137 301 52 20 Great Room 360 4135 1939 100 130 Living 156 6494 2517 157 169 Stairs 84 0 0 0 0 dining 120 1926 835 47 56 Foyer Closet/Mud 84 100 2629 1488 556 292 64 36 37 20 Kitchen Pan 196 16 3138 0 1617 0 76 0 108 0 Nook 108 2263 1156 55 77 UA1 58 0 0 0 0 \IA11 32 0 0 0 0 Stairs 2 84 0 0 0 0 _aundry 72 1777 fl&c IA ... Printout certified by ACCA to meet all requirements of Manual J 8th Ed. r". wrightsoft- Right -Suite Residential 6.0.117 RSR29907 ACC!'1 C:\Documents and SettingslThomas H. ElanderlDesktop\Wrightsoft Heat Loss\Lennar 6008.rrp Calc = M 2010 -Aug -23 0998:32 Page 1 Master Bed Master bath Bed 2 B2 Closet J&J Bath Loft Bed 4 Closets Bed 3 hall bath NA2 240 130 192 35 77 224 154 65 156 54 308 3935 2248 2517 859 893 3724 2770 1500 3218 0 0 1823 653 1420 175 227 1108 2021 475 1308 0 0 95 55 61 21 22 90 67 36 78 0 0 122 44 95 12 15 74 135 32 88 0 0 Entire House Other equip loads Equip. @ 0.93 RSM Latent cooling d 4863 64173 10404 20646 2214 21236 4839 1556 1383 TOTALS 4863 74577 26075 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 1556 1383 wrightsoft- Right -Suite Residential 6.0.117 RSR29907 ACCA C:1Documents and Settings\Thomas H. Elander\Desktop Wrightsott Heat Loss\Lennar 6006.rrp Calc = M 2010 -Aug -23 09:26:32 Page 2 -�- wrightsoftt Building Analysis Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott Desi: n Conditions Location: Minneapolis -St. Paul, MN, US Elevation: 837 ft Latitude: 45°N Outdoor: Dry bulb (°F Daily range °F) Wet bulb (° Wind speed mph) Heating -16 15.0 Cooling 88 (M ) 71 7.5 Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Moisture difference (gr/Ib) Infiltration: Method Construction quality Fireplaces Heatin`• Com onent Btuh/ft2 Btuh % of load Walls 5.7 36031 48.3 Glazing 24.6 6910 9.3 Doors 28.0 1174 1.6 Ceilings 1.7 4221 5,7 Floors 2.0 4061 5.4 Infiltration Ducts 3.3 10232 1545 13.7 2.1 Piping 0 0.0 Humidification 5815 7.8 Ventilation Adjustments 4589 0 6.2 Total 74577 100.0 Caolin• Component Btuh/ft2 Btuh % of Toad Wails 0.7 4197 18.4 Glazing 26.1 7321 32.0 Doors 9.1 380 1.7 Ceilings 1.3 3218 14.1 Floors 0.1 118 0.5 Infiltration 0.6 1892 8.3 Ducts 940 4.1 Ventilation 848 3.7 Internal gains Blower Adjustments 2580 1365 0 11.3 6.0 Total 22859 100.0 Overall U -value = 0.059 Btuh/ft2-°F Data entries checked. Heating 86 50 54.6 Simplified Semi -tight 1 (Semi -tight) Cooling72 16 50 32.7 1 -PP- wrightsof't` Right -Suite Residential 6.0.117 RSR29907 2010 -Aug -23 09:28:32 AC CN C:\Documents and Settings\Thomas H. EianderADesktop\Wrightsoft Heat LocalLennar 6008.rrp Calc = M Page 1 -- wrightsofte Component Constructions Entire House Elander Mechanical Inc. Job: 8008 Date: August 11,2010 By: Scott Project Information For: Design Conditions Location: Minneapolis -St. Paul, MN, US Elevation: 837 ft Latitude: 45 °N Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) 15.0 Heating -16 Cooling 88 19 (M) 71 7.5 Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Moisture difference (gr/Ib) Infiltration: Method Construction quality Fireplaces Heating 70 86 50 54.6 Simplified Semi -tight 1 (Semi -tight) Cooling 72 16 50 32.7 Construction descriptions Or Area U -value Insul R Htg HTM 11, 8wh/lt'-'F n= °Fieluh Btuh/a= Walls 12E-5sw: Wood stud frame, siding or stucco, R-5 foam board, R-19 n cavity insulation e s w all 12E-2sw: Wood stud frame, siding or stucco, R-2 foam board, R-19 n cavity insulation $ w all 15B-4sfc-8: Basement - 8° concrete, no framing or interior finish, n R-4 foam bd to floor, 8' e s w all Partitions 12C-Osw: Wood stud frame, siding or stucco, no board insulation, R-13 cavity insulation Windows 4A1-2oc: Operable, metal clad wood frame, low -e glass, a=0.20 surface 2, 2 pane; NFRC rated (SHGC=0.30); 50% indoor insect screen 4A1-2oc: Operable, metal clad wood frame, low -e glass, e=0.20 surface 2, 2 pane; NFRC rated (SHGC=0.27); 50% indoor insect screen 4A1-2oc: Operable, metal clad wood frame, low -e glass, e=0.20 surface 2, 2 pane; NFRC rated (SHGC=0.29); 50% indoor insect screen 4A1-2oc: Operable, metal clad wood frame, low -e glass, e=0.20 surface 2, 2 pane; NFRC rated (SHGC=0.25); 50% indoor insect screen n n e s all e w all e w all s Loss CIg HTM Gain Btu?) BtuMU4P Btuh 813 0.052 24.0 3.93 3193 0.64 522 657 0.052 24.0 4.23 2776 0.69 454 535 0.052 24.0 4.47 2391 0.73 391 528 0.052 24.0 4.47 2362 0.73 386 2533 0.052 24.0 4.23 10723 0.69 1752 43 0.063 21.0 0.00 0 0.00 0 42 0.063 21.0 0.00 0 0.00 0 144 0.063 21.0 0.00 0 0.00 0 229 0.063 21.0 0.00 0 0.00 0 352 0.072 4.0 6.19 2180 0.00 0 384 0.072 4.0 6.19 2378 0.00 0 345 0.072 4.0 6.19 2135 0.00 0 384 0.072 4.0 6.19 2378 0.00 0 1465 0.072 4.0 6.19 9070 0.00 0 2075 0.091 13.0 7.83 16239 1.18 2445 15 0.300 0.0 25.8 374 9.91 144 13 0.300 0.0 0.00 0 0.00 0 50 0.300 0.0 25.8 1290 31.1 1556 13 0.300 0.0 25.8 343 17.8 236 90 0.300 0.0 22.2 2007 21.4 1936 90 0.300 0.0 25.8 2322 28.5 2561 62 0.300 0.0 25.8 1595 28.5 1760 152 0.300 0.0 25.8 3917 28.5 4321 6 0.300 0.0 25.8 159 30.2 186 21 0.300 0.0 25.8 542 30.2 635 27 0.300 0.0 25.8 700 30.2 821 7 0.280 0.0 24.1 175 15.3 111 wrightsoft- Right -Suite Residential 6.0.117 RSR29907 RCCA C:1Documents and Settings\Thomas H. ElandenDesktop\Wrightson Heat LosslLennar 6008.rrp Calc = M 2010 -Aug -23 09:28:32 Page 1 4A1-2oc: Operable, metal clad wood frame, low -e glass, e=0.20 w 4 0.320 0.0 27.5 110 33.2 133 surface 2, 2 pane; NFRC rated (SHGC=0.32); 50% indoor insect screen Doors 1110: Metal door, fiberglass core, with storm e 21 0.360 0.0 31.0 650 10.0 211 11PO: Metal door, polyurethane core, no storm w 21 0.290 0.0 24.9 524 8.08 170 Ceilings 16A-44ad: Ceiling under unvented attic, no radiant barrier, dark 2031 0.022 44.0 1.48 2999 1.22 2488 shingles, R-44 insul. 1613-30ad: Ceiling under vented attic, no radiant barrier, dark 444 0.032 30.0 2.75 1222 1.64 730 shingles, R-30 insulation Floors 19C-19cscp: Carpeted floor over tight enclosed crawl, R-11 wall, 438 0.049 19.0 1.46 640 0.27 118 R-19 blanket 21A -24c: Carpeted basement floor, No insulation, 24' wide 1591 0.025 0.0 2.15 3421 0.00 0 . . wriightsoft- Right -Suite Residential 8.0.117 RSR29907 2010 -Aug -23 09:28:32 ACCA C:\Documents and Settings\Thomas H. Elander'DesktoplWrightsoit Heat Loss\lennar 6008,rrp Calc = M Page 2 - wrightsoft= Project Summary Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott Project Information For: Notes: Desi '• n information Weather: Winter Design Conditions Outside db Inside db Design TD Heating Summary Structure Ducts Central vent (50 cfm) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) -16 °F 70 °F 86 °F 62628 Btuh 1545 Btuh 4589 Btuh 5815 Btuh 0 Btuh 74577 Btuh Heating 24914 024 Minneapolis -St. Paul, MN, US Summer Design Conditions Simplified Semi -tight 1 (Semi -tight) Cooling 4 27 24914 0.24 111 Heating Equipment Summary Make Trade Model Lennox Merit 90 G43 -48C-090-** Efficiency 92.1 AFUE Heating input 88000 Btuh Heating output 83000 Btuh Temperature rise 50 °F Actual air flow 1556 cfm Air flow factor 0.024 cfm/Btuh Static pressure 0.00 in H2O Space thermostat Outside db Inside db Design TD Daily range Relative humidity Moisture difference 88 °F 72 °F 16 °F M 50 % 33 gr/lb Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (50 cfm) Blower Use manufacturer's data Rate/swing multiplier Equipment sensible Toad 19706 Btuh 940 Btuh 848 Btuh 1365 Btuh 0.93 21236 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Central vent (50 cfm) Equipment latent load Equipment total Toad Req. total capacity at 0.70 SHR 3605 Btuh 155 Btuh 1079 Btuh 4839 Btuh 26075 Btuh 2.5 ton Cooling Equipment Summary Make Lennox Trade 13ACX Series - RFC Cond 13ACX-042-230-* Coil C33-43*+TDR Efficiency 13 SEER Sensible cooling 29050 Btuh Latent cooling 12450 Btuh Total cooling 41500 Btuh Actual air flow 1383 cfm Air flow factor 0.067 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.83 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 441- wa-igtatsoft• Right -Suite Residential 8.0.117 RSR29907 2010 -Aug -23 09:28:32 ACCP. C:\Documenis and Settings\Thomas H. Elander'Desktop\Wrightsoft Heat Loss\Lenner 6008.rrp Calc = M Page 1 wrightsofty Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Entire House 516.0 ft 8.7 ft 4863.0 IP d Basement 184.0 ft 8.0 ft heaVcool 1.0 x 1536.0 ft 1536.0 ft2 6 11 Ty Construction number 12E-Ssoi, 4A1-2oc:.. 12E-2sw 4A1-2oc .15B 4sfG8 12E-5sw 4A1.2oc 4A1-2oc 4A1-2oc 11KO 15BAsfc-8 12E-5sw 4A1-2oc 12E-2sw` 15B-4sfc-8 4A1.2oc 12E-2sw. 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11P0 158-4sfc-8 12C-Osw 16A44ad 16B-30ad 19C-l9cscp 21A -24c U -value (Btuh/ft2-°F) 0.052 0.300 0.063 0.300 0.165 0.052 0.300 0.300 0.300 0.360 0:165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0.165 0.091 0.022 0.032 0.049 0.025 • Or n. n n OE e e e e e 0: 8 s. • s.• s s ` w: w w w w w w. HTM (BtuWtta) Area ft2) or perimeter (ft) Load (Btuh) Area ft2) or perimeter (ft) Load (Btuh) Heat 4.47 25.80 5.42 25.80 6.19 4.47 25.80 25.80 25.80 30.98 6,19 4.47 25.80 5.42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1.89 2.75 1:46 2.15 Coot 0.73 9,91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 0.73 17.78 ;:1.05 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1:57 1.64 0.27 0.00 Gross 828 15 56 13 352 824 90 6 50 21 384 548 13 42 352 7 144 636 4 62 21 21 :384 2075 2031. 444 '438 1591 N/P/S 813 0 43 0 352 657 0 0 0 21 384 535 0 345 0 144 528 0 0 0 21 384 2075 2031 444 52 191 Heat 3193 374 0 0 2180 2776 2322 159 1290 650 - 2378 2391 343 2135 175 0 2362 110 1595 542 524 2378 16239 :::2999 1222 640 3421 Cool 522 144 0 0 0 454 2561 186 1556 211 0 391 236 0 0 111 0 386 133 1760 635 170 0 2445 2488 730 :118 0 Gross 0 .0 0 0 352 0 0 0 0 0 384 0 0 0 352 7 0 0 0 0 0 N/P/S 0 0 0 0 352 0 0 0 0 0 384 0 0 0 345 0 0 Heat 0 0 0 0 2180 0 0 0 0 0 2378 0 0 2135 175 0 0 0 0 0 0 2378 0 0 523 3302 Cool 0 0 0 0 0 0 0 0 0 0 0 0 0 0 111 0 0 0 0 6 c) AED excursion 0 -14 Envelope toss/gain 52396 15234 13070 409 12 a) Infiltration b) Room ventilation 10232 0 1892 0 0 0 0 0 13 Internal gains: Occupants 42 230 Appliances @ 1200 6 1 1380 1200 0 0 0 0 Subtotal (lines 6 to 13) 62628 19706 13070 409 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 2% 5% 0 0 0 62628 1545 0 0 0 19706 940 0% 0 0 0 13070 0 0 0 0 409 0 Total room Toad Air required (elm) 64173 1556 20646 1383 13070 317 409 27 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. c wripffttsorr- Right -Suite Residential 6.0.117 RSR29907 �1+ CADocuments and Settings\Thomas H. ElanderlDesktop\Wrightsoft Heat Loss\Lennar 6008.np Cato = M 2010 -Aug -23 0928:32 Page 1 -- wrightsoft' Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area 26.Study 0fl 9.0 ft heat/cool 14.0 x 12.0 ft 166.0 fP 3/4 Bath 6.0 It 9.0 ft heat/cool 9.0 x 6.0 ft 54.0 02 6 1i Ty w:;'< P C F Construction number 12E 5sw: 4A1-2oc': 12E•2sw 4A1.2oc 15B-4sfc-8 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 156-4sfc-8 12E-5sw 4A1-2oc :12E=2sw:: 158-4sfc-8 4A1-2oc.. 12E=2sw: 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11P0 156=4sfc=8 12C-Osw 16A.44ad 16B-30ad 19G19cscp 21A -24c U -value (Btuh/ft2-"F) 0.052 0.300 0.063 0.300 0.165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 is 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0:165 0.091 0.022 0.032 0.049 0.025 Or .• ns n n :n.. e e e e e e`;:. s s ss.`i s s w. w w w w w HTM (Btuhlft2) Area ft2 or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat 4:47 25.80 5.42 25.80 6:19 4.47 25.80 25.80 25.80 30.96 4.47 25.80 5:42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1.89 2.75 1.46 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2:32 0.73 17.78 1.05 2.32 15.27 0.73 33.19 28.46 30.23 8.08 x::;2.32 1.18 1.57 1.64 0.27 0.00 Gross 0 0 0 126 0 0 25 0 .0 N/P/S 0 0 0 101 0 0 0 0 108 0 0 0 0 0 0 0 0 0 0 0 126 0 0 0 0 Heat 0 0 0 0 452 0 0 645 0 0 483 0 Cool `0 0 0 0 0 74 0 0 776 0 0 79 0 0 0 0 0 0 0 0 0 Gross 0 0 0 0 0 0 0 0 0 0 0 54 0 0 0 0 0 0 0 0 0 0 N/P/S .0 0 0 0 - 0 0 0 0 0 0 Heat ..0 0 0 0 0 0 0 0 : 0 241 0 0 0 0 0 0 0 0 0 0 Coot 0 0 0 0 0 0 0 0 0 0 39 0 0 0 0 0 0 0 0 0 6 c) AED excursion -25 -31 Envelope loss/gain 2566 1054 1932 263 12 a) Infiltration b) Room ventilation 887 0 164 0 205 0 38 0 13 Internal gains: Occupants @ 230 Appliances @ 1200 1 0 230 0 0 0 0 0 Subtotal pines 6 to 13) 3452 1448 2137 301 14 15 Less extemat load Less transfer Redistrtibulion Subtotal Duct Toads 0% 0% 0 0 0 3452 0 0 0 0 1448 0 0% 0% 0 0 0 2137 0 0 0 0 301 0 Total room bad Air required (cfm) 3452 84 1448 97 2137 52 301 20 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. �- -►`I} `^'ra+atits4rt• Right -Suite Residential 6.0.117 RSR29907 CADocuments and Settings\Thomas H. Elander\Desktop\Wdghtsoft Heat Loss\Lennar 6008.rrp Calc = M 2010 -Aug -23 09:28:32 Page 2 -- wrightsoft' Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Great Room 22.0 ft 9.0 ft heaUcool 18.0 x 20.0 ft 360.0 ft2 Living 27.0 ft 17.0 fl heat/cool 12.0 x 13.0 ft 156.0 ft2 6 11 6 Ty Construction number .12E-55id; 4A1-2oc. 12E-2sw 4A1-2oc. 1513431c=8 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 15B4sfc-8 12E-5sw 4A1.2oc 12E-2sw; 158-4sfc-8 4A1.2oc 12E-2sw:: 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 1 i 1513=4sfc-8 12C-Osw 16A-44ad 168-30ad 190.19csc p 21A -24c U -value (BtuMt2-°F) 0.052 0.300 0.063 0.300 ;'0165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0.165 0.091 0:022 0.032 •::::0.049 0.025 Or n.; n. n n n e e e e 0 e s s s s .:w.. w w w w w HIM (Btuh/ft2) Area ft2) or perimeter (ft) Load (Btuh) Area ft2) or perimeter (ft) Load (Stull) Heat 4:47 25.80 5.42 25.80 = 6.19 4.47 25.80 25.80 25.80 30.96 6.19 4.47 25.80 5.42 6.19 24.08 5:42 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1:89 2.75 1A6 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 2.32 15.27 ::.1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1.57 1.64 0.27 0.00 Gross 36 0 0 0 162 45 0 0 0 0 0 0 .0 0 0 0 0 0 0 N/PIS 36 0 0 0 0 117 0 0 0 0 0 0 0 0 Heal 161 0 0 0 523 1161 0 0 0 0 0 0 0 0 0 0 0 0 0 Cool :. 2 8 128 Gross 221 0 0 0 0 0 0 0 0 34 0 0 0 0 o 204 0 25 13 0 N/P/S • 221 0 0 0 0 0 0 0 0 0 0 34 0 0 0 0 166 0 0 0 0 Heat 988 • 0 0 0 0 0 0 0 0 0 152 0 0 0 742 0 645 335 0 Coot :161 0 0 0 0 0 0 0 0 25 0 0 0 0 0 121 0 711 393 0 0 240 245 0 0 c) AED excursion -8 298 Envelope loss/gain 3385 1801 4755 2195 12 a) Infiltration b) Room ventilation 750 0 139 0 1739 0 322 0 13 Internal gains: Occupants @ 230 Appliances 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 4135 1939 6494 2517 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0% 0 0 0 4135 0 0 0 0 1939 0 0% 0% 0 0 0 6494 0 0 0 0 2517 0 Total mom load Air required (cfm) 4135 100 1939 130 6494 157 2517 169 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ietik- ' .rigt'nt..ort• Right -Suite Residential 6.0.117 RSR29907 C:\Documents and Settings\Thomas H. Elander\Desktop\Wrightsoft Heat Loss\Lennar 6008.rrp Caic = M 2010 -Aug -23 09:28:32 Page 3 -- wrightsoft' Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Stairs 7.0 ft 9.0 ft uncondiL 12.0 x 7.0 ft 84.0 f12 dining 10.0 ft 9.0 ft heat/cool 10.0 x 12.0 ft 120.0 SR 6 11 Ty Construction number 12E-5sw: 4A1=2oc 12E-2sw 4A1-2oc 15B 4sfc.8 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 158=4sfc-8 12E-5sw 4A1-2oc. 12E 2sw: 15B-4sfc-8 4A1-2oc 12E•25w):: 12E-5sw 4A1-2oc 4A1-2oc 4A1.2oc 11P0 158 4sfc.8 12C-Osw 16A=44ad 16B-30ad 21A -24c U -value (Btuh/112-°F) 0.052 0.300 0.063 0.300 0:185 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0.165 0.091 0:022 0.032 0.049 0.025 Or : n: n n n.. e e e e e s s s. s $ w w w w w w HTM (8tuh/fl2) Area 112) or perimeter (It) Load (Btuh) Area ft2) or perimeter (ft) Load (Btuh) Heat 4.47 25:80 5.42 25.80 6:19 4.47 25.80 25.80 25.80 30.96 6.19 4.47 25.80 5:42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1:89 2.75 1.46 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 1.05 2.32 15.27 :i1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1.57 1.64 '0.27 0.00 Gross 63 •.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N/P/S 63 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Heat Cool 0 0 0 0 0 0 0 0 0 0 0 Gross 0 0 0 0 0 0 0 0 0 0 0 0 0 f::0 0 0 0 90 0 16 0 0 ,..,0 108 0 0 N/P/S 7 Heat 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 332 0 409 0 0 Cool 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 54 0 451 0 0 0 127 0 6 c) AED excursion 0 140 Envelope toss/gain 0 0 1585 772 12 a) Infiltration b) Room ventilation 0 0 0 0 341 0 63 0 13 Internal gains: Occupants 0 230 Appliances 0 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0 0 0 0 0 0 0 0 0 0 0 0 1926 835 0% 0% 0 0 0 1926 0 0 0 0 835 0 Total room load Air required (cfm) 0 0 0 0 1926 47 835 56 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -F{++- wriyr.tso2re- Right -Suite Residential 6.0.117 RSR29907 A C:\Documents and SettingaThomas H. Elander\Desktop\Wrightsoft Heat Loss\Lennar 6008.rrp Calc = M 2010 -Aug -23 09:28:32 Page 4 wrightsofr Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 Sy: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Foyer 6.0 ft 17.0 ft heat/cool 6.0 x 14.0 ft 84.0 ft, Closet/Mud 0.0 ft 9.0 ft heat/cool 10.0 x 10.0 ft 100.0 ft2 6 11 Ty w. p. F Construction number 12E-2sw 4A1-2oc, 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11 KO .• 15154sf68 12E-5sw 4A1-2oc 158-4sfc-8 4A1-2oc 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11P0 120-0sw 168-30ad IOC l9oscp 21A -24c U -value (Bturint,-*F) 0.052 0.300 0.063 0.300 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0.091 0.022 0.032 .0.049 0.025 Or n n. • n n e e s e w w w w w w HTM (Btuh/lt2) Area ft,) or perimeter ((t) Load (Btuh) Area ft2) or perimeter ((t) Load (B(uh) Heat 4.47 5.42 25.80 6.19 4.47 25.80 25.80 25.80 30.96 6.19 4.47 25.80 542 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6.19 7.83 1.89 2.75 1.46 2.15 Cool 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 1.05 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 1.18 1.57 1.64 0.27 0.00 Gross 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 102 0 0 0 21 153 Ett N/P/S 0 0 0 0 0 0 0 0 0 0 0 00 0 0 81 0 0 0 21 0 153 84 0 0 Heat •••• 0 0 ::0 0 0 0 0 0 0 0 0 0• 0 0 362 0 0 0 524 0 1197 159 0 0 0 Cool 0 0 0 0 0 0 0 0 0 • 0 0 0 0 0 0 59 0 0 0 170 8 Gross 0 0 0 0 00 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 162 0 80 0 0 N/P/S 162 8 Heat 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 • 0 1268 • . 0 220 0 0 Cool 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 191 131 0 6 c) AED excursion .57 40 Envelope loss/gain 12 a) Infiltration b) Room ventilation 2242 386 0 484 71 0 1488 0 0 292 0 0 13 Internal gains: O�upants@ 230 Appliances @ 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 2629 556 1488 292 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0%0 0 0 0 2629 0 0 0 556 0 00 0 0 1488 0 0 0 292 0 Total room load Air required (cfm) 2629 64 556 37 1488 36 292 20 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -14*-wrihtft.. Flight -Suite Residential 6.0.117 RSR29907 ACON CADocuments and Settings‘Thomas H. ElandenDesktop\Wrightsoft Heat Loss\Lennar 6008srp Calc = M 2010 -Aug -23 0928:32 Page 6 +�- wrightsoft Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Kitchen 16.0 it 9.0 ft heaVcool 1.0 x 196.0 ft 196.0 112 Pantry 8.0 ft 9.0 ft uncondit. 4.0 x 4.0 ft 16.0 ft2 6 11 6 Ty Construction number 12E-5sw 4A1-2oc. 12E-2sw 4A1-2oc 158-4sfc-8'. 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 158-4sfc-8 12E-Ssw 4A1-2oc 12E=2sw.: 15B-4sfc-8 4A1-2oc :12E -26w.: 12E-5sw 4A1-2oc 4A1-2oc 4A1.2oc 11P0 1513 48fc-8 12C-Osw 16A 44ad 16B-30ad 19C-19cscp . 21A -24c U -value (Btuhff(2'F) 0.052 0.300 0.063 0.300 0:165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0.165 0.091 0:022 0.032 0.049 0.025 c) AED excursion Or n;. n n ri. e e e e e e;; s s s- $ $ w.' w w w w w HTM (Btuh/ft2) Area f12) or perimeter (ft) Load (Btuh) Area ft2) or perimeter (ft) Load (Btuh) Heat 4.47 25.80 5.42 25.80 6:19 4.47 25.80 25.80 25.80 30.96 6:19 4.47 25.80 5.42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1.89 2.75 1:46 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 1.18 1.57 1.64 0.27 0.00 Gross 144 N/PIS 135 0 0 0 0 0 0 0 0 ,0 0 0 0 0 0 0 0 0 0 0 0 0 216 0 24 0 0 Heat 604 232 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1690 66 0 0 Cool 89 0 0 0 0 0 0 0 0 0 0 0 s0 0 0 0 0 0 0 0 0 255 39 0 0 Gross N/P/S : 36 0 0 0 0 36 0 0 0 0 0 0 0 f. 0 0 0 0 0 0 0 0 0 38 0 0 0 0 36 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Heat 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 Cool 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ..0 0 0 0 -165 0 Envelope loss/gain 2592 317 0 0 12 a) Infiltration b) Room ventilation 546 0 101 0 0 0 0 0 13 Internal gains: Occupants ® 230 Appliances 1200 0 0 1200 0 0 0 0 Subtotal (lines 6 to 13) 3138 1617 0 0 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0% 0 0 0 3138 0 0 0 0 1617 0 0% 0% 0 0 0 0 0 0 0 0 0 0 Total room load Air required (cfm) 3138 76 1617 108 0 0 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. "�- W.-staftrsort. Right -Suite Residential 6.0.117 RSR29907 ACOA C:1Documents and Settings\Thomas H. ElanderlDesktop\Wrighisoft Heat Loss%Lennar 6008.rrp Calc = M 2010 -Aug -23 09:28:32 Page 6 wrightsot' Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Nook 12.0 ft 9.0 ft heat/cool 12.0 x 9.0 ft 108.0 1t2 NA1 2.0 ft 9.0 fl uncondit. 1.0 x 58.0 It 58.0 ft^ Ty Construction number U -value (Btuh/ftt-°F) Or HTM (Btuhlft2) Area IP) or perimeter (ft) Load (Btuh) Area ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 6 w W 12E-5sW 4A1.200 12E-2sw 4A1-2oc 155.4sfo 8 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 15B 4sfG8 12E-5sw 4A1-2oc 12E-2swi 15B-4slc•8 4A1-2oc 12E-2swi • 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11P0 15B:=4sfc-8 12C-Osw 16A-44ad :....;. 16B-30ad 19C-19cscp .. 21A -24o 0:052 0.300 0.063 0.300 '::.0165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0:063 0.165 0.280 0:063 0.052 0.320 0.300 0.300 0.290 '0.165 0.091 ••:0:022 0.032 1�0:049 0.025 c) AED excursion n n n n:. e e e e e.. s s s s w. w w w w w w? 4.47 25.80 5.42 25.80 6.19 4.47 25.80 25.80 25.80 30.96 4.47 25.80 5:42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1.89 2.75 1:46 2.15 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2:32 0.73 17.78 1:05 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 2:32 1.18 1:57. 1.64 0.27 0.00 0 0 0 0 0 108 0 0 25 21 0 0 0 0 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 0 62 0 0 0 21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 277 0 0 645 650 0 0 0 0 0 0 0 0 0 0 0 0 0 282 0 0 0 0 45 0 0 778 211 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 0 Envelope loss/gain 1854 1081 0 0 12 a) Infiltration b) Room ventilation 409 0 76 0 0 0 0 0 13 Internal gains: Occupants 0/ 230 Appliances 0 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) Less external bad Less transfer Redistribution 14 Subtotal 15 Duct loads 0% 0°% 2263 1156 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2263 1156 0 0 0 0 0% 0% 0 0 Total room load Air required (cfm) 2263 55 1156 77 0 0 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wcivlhtaaort- Right -Suite Residential 6.0.117 AucK C:\Documents and SettingslThomas H. ElanderlDesktop\Wrightsoft Heat Lossll.ennar 6008.np Calc = M 2010 -Aug -23 09:28:32 Page 7 - - wrightsoft Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area NA11 0.0 ft 9.0 ft uncondit. 1.0 x 32.0 ft 32.0 IF Stairs 2 22.0 ft 8.0 ft uncondit. 12.0 x 7.0 ft 84.0 fl2 6 11 6 Ty w i P c F Construction number 12E 5sw: 4A1-200 12E-2sw 4A1.2oc 1513.4sfc-8 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 15B=4sfc-8 12E-5sw 4A1-2oc 15B-4sfc-8 4A1-2oc 12E-2aw: 12E-ssw 4A1-2oc 4A1-2oc 4A1-2oc 11P0 15B4Isle-8:i;: 12C-Osw 16A448b: 16B•30ad 19C=19cscp 21A -24c U -value (8tuh/fl2 °F) 0.052 0.300 0.063 0.300 0.165 0.052 0.300 0.300 0.300 0.360 0:165 0.052 0.300 i 0.063 0.165 0.280 0:063 0.052 0.320 0.300 0.300 0.290 0:165 0.091 0.032 0.049 0.025 Or n: n n e e e e e s .0. S s s w. w w w w w HTM (Btuh/f12) Area (t2) or perimeter (ft) Load (Btuh) Area 1t2) or perimeter (f1) Load (Btuh) Heat 4,47 25.80 5.42 25.80 6.19 4.47 25.80 25.80 25.80 30.96 6:19 4.47 25.80 5.42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6.19 7.83 1:89 2.75 1.46 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 1.05 2.32 15.27 ;::.1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1.57 1.64 0.27 0.00 Gross 0 0 0 `0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N/P/S 0 0 0 0 0 0 0 0 0 0 0 0 0 :0 0 0 0 0 0 0 0 Heat .0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r0 0 0 0 Cool 0 0 0 0 0 0 0 0 0 0 0 0 0 '.0 0 0 0 0 0 0 0 0 0 0 0 0 0 Gross :0 56 13 0 0 0 0 0 0 0 0 24 0 0 98 0 0 0 0 N/P/S Heat 0 0 43 0 0 0 0 0 0 0 0 0 24 0 0 96 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cool 0 0 0 0 0 0 0 0 =0 0 0 ;0 0 0 %r0 0 0 0 0 0 0 0 0 0 0 c) AED excursion 0 0 Envelope loss/gain 0 0 0 0 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances 4§ 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0% 0 0 0 0 0 0 0 0 0 0 0 0 0% 0% 0 0 0 0 0 0 0 0 0 0 0 0 Total room toad Air required (cfm) 0 0 0 0 0 0 0 0 Printout certified by ACCA to meet ail requirements of Manual J 8th Ed. wrigFalsorr Right -Suite Residential 6.0.117 RSR29907 A CADocumenls and Settings\Thomas H. Elander\Desktop\Wrightsoft Heat Loss\Lennar 6008,rrp Calc = M 2010 -Aug -23 09:28:32 Page 8 -d- wrightsoft• Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Laundry 6.0 ft 8.0 ft heat/coof 12.0 x 6.0 ft 72.0 112 Master Bed 31.0 ft 8.5 ft heat/coot 16.0 x 15.0 ft 240.0 JP Ty Construction number U -value (Btuh/ft2-°F) Or HTM (BtutJft2) Area 1(2) or perimeter (ft) Load (Btuh) Area i(2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ' G P c C F F .12E-5sw. 4A1-2oc:: 12E-2sw 4A1-2oc .158=4SfC-8 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 15B 4sfc-8 12E-5sw 4A1-2oc, 12E-2sw 15B-4sfc-8 4A1.2oc 12E-2sw:: 12E-Ssw 4A1-2oc 4A1-2oc 4A1-200 11P0 15B-49fc-8 12C-0sw 16A-44ad 168-30a9. 21A-24c 0.052 0.300 0.063 0.300 0.165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0:165 0.091 0.022 0.032 0.049 0.025 n!• n n rlr e e e e e s s s 5 w.: w w w w w 4.47 25.80 5.42 25.80 6.19 4.47 25.80 25.80 25.80 30.96 6:19 4.47 25.80 5.42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1.89 2.75 1:46 2.15 0.73 8.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1.57 1.64 0:27 0.00 48 .:8 0 0 .0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 43 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 144 :.72 0 0 0 190 142 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1127 . 136 0 31 54 0 0 0 0 0 0 0 0 0 0 0 s:0 0 0 0 0 0 0 0 128 0 0 0 136 21 0 0 0 '.0 0 0 0 0 0 0 0 0 0 :128 11 570 0 0 0 0 514 542 0 0 0 0 0 0 0 0 0 .0 0 0 0 0 0 93 0 0 ' 0 84 598 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 c) AED excursion -37 -97 Envelope loss/gain 1595 331 2936 1179 12 a) Infiltration b) Room ventilation 182 0 34 0 998 0 185 0 13 Internal gains: Occupants 4 230 Appliances @ 1200 0 0 0 0 2 0 460 0 Subtotal (lines 6 to 13) 1777 365 3935 1823 14 15 Less external load Less transfer Redistribution Subtotal Duct Toads 0% 0% 0 0 0 1777 0 0 0 0 365 0 0% 0 0 0 3935 0 0 0 0 1823 0 Total room Toad Air required (cfm) 1777 43 365 24 3935 95 1823 122 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. }+ wracr - sore• Right -Suite Residential 6.0.117 RSR29907 Auot% C:tDocuments and Settings1Thomas H. ElandeADesktop\Wrightsoft Heat Losstennar 6008.rrp Cate = M 2010 -Aug -23 0928:32 Page 9 -- wrightsoft Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Master bath 18.0 ft 8.0 11 heat/cool 13.0 x 10.0 ft 130.0 ft2 Bed 2 12.0 ft 8.0 ft heat/cool 12.0 x 16.0 ft 192.0 ft2 Ty Construction number U -value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (12) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1t 6 12E-5sw:: 4A1-2oc' 12E-2sw 4A1-2oc 15B14sfc-8 12E-5sw 4A1-2oc 4A1.2oc 4A1.2oc 11K0 15B.4sfc-8 12E-5sw 4A1.2oc 12E-2sw 15B-4sfc-8 4A1.2oc, 12E.2sw: , :. 12E-5sw 4A1.2oc 4A1-2oc 4A1.2oc 11P0 15B:4sfc-8 12C-Osw 16A-44ad ... ...... 16B-30ad 19C-19cscp 21A -24c 0.052 0.300 0.063 0.300 0:165 0.052 0.300 0.300 0.300 0.360 0:165 0.052 0.300 0.063 0.165 0.280 0.083 0.052 0.320 0.300 0.300 0.290 0.165 0.091 0.022 0.032 0.049 0.025 ;. n: n n n e e e e e.. .:'e 5 5 s 5 :w w w w w w w,` 4:47 25.80 5.42 25.80 6.19 4.47 25.80 25.80 25.80 30.96 6.19 4.47 25.80 5:42 6.19 24.08 542 4.47 27.52 25.80 25.80 24.94 6.19 7.83 1.89 2.75 146 2.15 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1.57. 1.64 0.27 0.00 24 0 0 0 104 0 6 0 0 0 0 0 i0 0 0 0 0 0 0 0 0 24 0 0 0 98 0 0 0 0 0 0 0 0 0 0 0 0 0 0 107 0 0 0 0 438 0 159 0 0 '.0 0 0 :0 0 0 1:0 0 0 0 0 0 814 • 246 0 0 0 18 0 0 0 71p 0 186 0 0 0 0 0 0 0 0 0 0 0 0 123 204 0 0 0 0 0 96 24 0 0 0 0 0 0 0 0 0 0 0 0 0 104 192 0 24 0 0 0 0 :: 0 72 0 0 0 0 0 0 0 0 0 0 :0 0 0 0 0 0 0 0 0 0 322 619 0 0 0 0 0 0 0 0 0 0 0 0 0 ••; i 0 0 0 0 53 683 0 0 0 0 0 0 0 0 0 0 0 0 c) AED excursion -38 Envelope loss/gain 1763 564 2153 -44 1122 12 a) Infiltration b) Room ventilation 485 0 90 0 364 0 67 0 13 Internal gains: Occupants 41 230 Appliances @ 1200 0 0 0 0 0 Subtotal (lines 6 to 13) 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0% 2248 0 0 0 2248 0 653 0 0 0 653 0 0% 0`Y. 2517 0 0 0 2517 0 230 0 1420 0 0 0 1420 0 Total room load Air required (cum) 2248 55 653 44 2517 81 1420 95 Printout certified y ACCA to meet all requirements of Manual J Bth Ed. -144- wr'=9htsoTC Right -Suite Residential 6.0.117 RSR29907 "M.A." C:tDocuments and Settings\Thomas H. Elander\Desktop\Wrightsoft Heat LosslLennar 6008.up Calc M 2010•Aug-23 0928:32 Page 10 -- wrightsoft Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area B2 Closet 12.0 fl 8.0 1t heat/cool 7.0 x 5.0 ft 35.0 112 J&J Bath 11.0 ft 8.0 ft heat/cool 7.0 x 11.0 h 77.0 ft2 6 11 6 Ty W' w, Construction number •12E SsiN: 4At 2oc 12E-2sw 4A1-2oc 15B 4sfc-8 12E-5sw 4A1-2oc 4A1.2oc 4A1.2oc 11K0 15B-4sfc-8 12E-5sw 4A1.2oc 12E-2sw;: 156.4sfc-8 4A1 -20c. ..... 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11PO 15B=4sfs:6 12C-Osw 16A-44ad 16B-30ad 19C-.19cscp 21A -24c U -value (Btuh/ft2- F) 0.052 0.300 0.063 0.300 0.165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0:063 0.165 0.280 0.063 0.0.52 0.320 0.300 0.300 0.290 0.165 0.091 0.022 0.032 0.049 0.025 c) AED excursion Or n n.. e e e e e s $ s s w w w w w w w.:. MTM (Btuh/ft2) Area ft') or perimeter (ft) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat 4:47 25.80 5.42 25.80 6:19 4.47 25.80 25.80 25.80 30.96 6:19 4.47 25.80 6.19 24,08 5A2 4.47 27.52 25.80 25.80 24.94 7.83 2.75 Cool . 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 1.05. 2.32 15.27 1:05 0.73 33.19 28.46 30.23 8.08 2:32 1.18 1:57 1.64 0.27 Gross 5 4 N/P/S .0 0 0 0 56 0 0 0 0 40 0 0 0 0 0 0 0 0 0 0 Heat 0 0 0 0 250 0 0 0 0 f0 179 0 0 0 0 .0 0 0 0 0 0 Cool • r;: 0 Gross 0 0 0 0 0 0 0 0 0 0 88 0 0 0 0 .0 0 0 0 0 0 0 0 77 • 0 14 0 N!P/S 0 0 0 0 0 0 0 0 88 0 0 0 0 0 0 0 0 0 Heat 0 0 0 0 0 0 0 0 0 394 0 0 0 0 0 0 0 0 0 0 0 146 Cool 0 0 0 0 0 0 0 0 0 0 64 0 0 0 0 0 0 0 0 0 0 0 0 121 0 0 -18 -23 Envelope loss/gain 496 107 560 166 12 a) Infiltration b) Room ventilation 364 0 67 0 333 0 62 0 13 Internal gains: Occupants Of 230 Appliances @ 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 859 175 893 227 14 15 Less external load Less transfer Redistribution Subtotal Duct Toads 0% 0% 0 0 0 859 0 0 0 0 175 0 0% 0% 0 0 0 893 0 0 0 0 227 0 Total room toad Air required (cfm) 859 21 175 12 893 22 227 15 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. w.-101wtsort• Right -Suite Residential 6.0.117 RSR29907 AC;(3A C:\Documents and SettingslThomas H. ElandetlDesktop\Wrighlsoft Heat Loss\Lennar 6008.rrp Calc = M 2010 -Aug -23 0928:32 Page 11 - • wrightsoft Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Loft 31.0 II 8.0 ft heaVcool 14.0 x 16.0 ft 224.0 ft2 Bed 4 12.0 ft 8.0 ft heaVcool 11.0 x 14.0 ft 154.0 1t2 6 11 Ty Construction number 12E-5sw 4A1-206. 12E-2sw 4A1.2oc 15B-45fo-8 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 1110 ;156=4sfc-8 12E-5sw 4A1-2oc 158-4sfc•8 4A1-2oc 12E-2sw:. 12E-5sw 4A1.2oc 4A1-2oc 4A1-2oc f1P0 156-4sfc-8 „ 12C-0sw 16A-44ad 168.30ad 190-19cscp 21A -24c U -value (13tuh/ff2-"F) 0.052 0.300 0.063 0.300 0.165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0.165 0.091 0.022 0.032 0.049 0025 Or n; n. n n n.. e e e e e e s s s s w w w w w w HIM (Btuh/ft2) Area ft2) or perimeter (ft) Load (Btuh) Area ft2) or perimeter (ft) Load (Btuh) Heat 4.47 25.80 5.42 25.80 6.19 4.47 25.80 25.80 25.80 30.96 6.19 4.47 25.80 5.42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6.19 7.83 1.89 2.75 1:46 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 1.05 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1.57 1.64 0.27 0.00 Gross 128 0 0 0 0 0 0 0 0 0 8 0 0 0 112 0 0 8 N/P/S 128 0 0 0 0 0 0 0 0 0 8 0 .'0 0 A 0 104 0 0 0 0 Heat 572 0 0 0 0 0 0 0 0 0 36 0 0 0 0 465 0 0 206 0 939 424 0 82 60 Cool 94 0 0 0 0 0 0 0 0 0 6 0 0 0 0 76 0 0 242 0 Gross 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 88 0 21 0 0 0 32 154 0 143 11 N/P/S 0 0 0 0 0 0 0 0 0 8 0 0 0 0 67 0 0 Heat 0 0 0 0 0 0 0 0 0 0 36 0 0 0 300 0 542 0 0 Cool 0 0 0 0 0 0 0 0 0 0 D 6 0 i0 0 0 0 49 0 598 0 0 6 c) AEO excursion Envelope loss/gain 9 154 2785 935 1652 1124 12 a) Infiltration b) Roam ventilation 940 0 174 0 364 0 67 0 13 Internal gains: Occupants @ 230 Appliances 4it 1200 0 0 0 0 0 230 0 Subtotal (lines 6 to 13) 3724 1108 2015 1421 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0% 0 0 0 3724 0 0 0 0 1108 0 37% 42% 0 0 0 2015 754 0 0 0 1421 599 Total room bad Air required (dm) 3724 90 1108 74 2770 67 2021 135 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ^� 4" wrigt�ltspTt Right -Suite Residential 6.0.117 RSR29907 AC A C:1Documents and SettingssThomas H. El ander\Desktop\Wrightsoft Heat Loss\Lennar 6008.rrp Calc = M 2010 -Aug -23 0928:32 Page 12 -- wrightsot Right -J Worksheet Entire House Elander Mechanical Inc. Job: 8008 Date: August 11,2010 By: Scott 2 3 4 5 Room name Exposed wap Ceiling height Room dimensions Room area Closets 18.0 it 8.0 ft heaUcool 5.0 x 13.0 ft 65.0 ft2 Bed 3 13.0 ft 8.0 ft heat/cool 12.0 x 13.0 ft 156.0 ft2 6 11 6 Ty W P C Construction number 12E•5sw :4A1-2oc 12E-2sw 4A1-2oc 1584sfc-8 12E-5sw 4A1-2oc 4A1.2oc 4A1.2oc 11K0 ;15B.4sic=8 12E-5sw 4A1.2oc 12E-2sw. 1513.4sfc-8 4A1-2oc 12E-2sw 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11P0 i56ytsfc-8 . 12C-Osw 16A=44ad 168-30ad 19C-19cscp 21A -24c U -value (Btuh/ft2-°F) 0.052 0.300 0.063 0.300 0.165 0.052 0.300 0.300 0.300 0.360 0.165 0.052 0.300 0.063 0.165 0.280 0.063 0.052 0.320 0.300 0.300 0.290 0165 0.091 0.022 0.032 0.049 0.025 c) AED excursion Or n;. n n e e e e e e; $ S . s, s s w`. w w w w w w,. HTM (Btuh/ft2) Area t2) or perimeter (ft) Load (Btuh) Area (ie) or perimeter (ft) Load (Btuh) Heat 4.47 25.80 5.42 25.80 6:19 4.47 25.80 25.80 25.80 30.96 6:19 4.47 25.80 5:42 6.19 24.08 542 4.47 27.52 25.80 25.80 24.94 6:19 7.83 1.89 2.75 1:46 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 0.73 17.78 1:05 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1:57 1.64 0.27 0.00 Gross 0 0 0 0 0 0 0 0 0 .;:.0 104 0 0 0 0 40 4 0 0 N/P/S 0 •:;0 0 0 0 0 0 0 0 0 0 104 0 0 0 0 36 0 Heat 0 0 0 0 0 0 0 0 0 465 0 0 0 0 161 110 0 0 0 0 0 123 0 Cool 0 .0 0 0 .0 0 0 0 0 0 0 76 0 0 0 0 0 26 133 Gross 0 0 0 0 0 0 0 0 0 104 13 0 0 0 0 0 0 0 0 0 0 104 156 0 N/P/S Heat 0 0 0 0 .0 0 0 0 0 0 91 0 0 0 0 0 0 0 0 0 0 ;0 0 0 0 0 0 0 0 ..0 406 343 0 0 0 0 0 0 0 0 0 0 814 295 0 175 0 Cool :0 0 0 0 0 0 0 0 0 66 19 -38 Envelope loss/gain 954 374 2033 665 12 a) Infiltration b) Room ventilation 546 0 101 0 394 0 73 0 13 Internal gains: Occupants n 230 Appliances @ 1200 0 0 0 0 1 0 230 0 Subtotal (lines 6 to 13) 1500 475 2427 968 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 0% 0% 0 0 0 1500 0 0 0 0 475 0 33% 35% 0 0 0 2427 791 0 0 0 968 341 Total room bad Air required (cfm) 1500 36 475 32 3218 78 1308 88 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ",,,i,„...tffioVt- Right -Suite Residential 6.0.117 RSR29907 ACCP- C:1Documents and Settings\Thomas H. ElandeADesktoppWrightsoft Heat Loss\Lennar 6008.rrp Catc = M 2010 -Aug -23 09:28:32 Page 13 wrightsoft Right -J Worksheet Entire House Elander Mechanical Inc. Job: 6008 Date: August 11,2010 By: Scott 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area hall bath 0.0 ft 8.0 ft uncondit. 9.0 x 6.0 tt 54.0 fP NA2 6.0 tt 8.0 ft uncondit. 1.0 x 308.0 ft 308.0 ft2 6 11 Ty W P F Construction number 4A1 200 12E-2sw 4A1-2oc .15B-4sfa4: 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11K0 12E-5sw 4A1-2oc 15B-4sfc-8 4A1-2oc 12E-5sw 4A1-2oc 4A1-2oc 4A1-2oc 11P0 12C-Osw 16B-30ad 21A -24c U -value (Eltuhrit2-°F) 0.052 0.300 0.063 • 0.300 0.052 0.300 0.300 0.300 - 872.2 0:,3 0.063 0.165 0.280 . . 0.083 0.052 0.320 0.300 0.300 0.290 0.165 0.091 : 0.049 0.025 Or n n n n e e e • e. $ ww w w w w HTM (Btuh/ft9 Area IP) or perimeter (ft) Load (Btuh) Area ft/ or perimeter (ft) Load (Btuh) Heat 4.47 25.80 5.42 25.80 a19 4.47 25.80 25.80 25.80 30.96 6.19 4.47 25.80 5.42 6.19 24.08 5.42 4.47 27.52 25.80 25.80 24.94 6.19 7.83 1.89 2.75 1.46 2.15 Cool 0.73 9.91 1.05 9.91 2.32 0.73 28.46 30.23 31.12 10.03 2.32 0.73 17.78 1.05 2.32 15.27 1.05 0.73 33.19 28.46 30.23 8.08 2.32 1.18 1.57 1.64 0.27 0.00 Gross 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 • 0 0 0 0 0 0 0 0 54 0 0 0 N/P/S 0 0 0000000.000 0 0 0 0 0 Heat 0 0 0 0 0 0 0 0 0 0 •-() 0 0 0 0 0 0 0 0 Cool 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Gross 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 0 0 0 0 0 0 0 308 0 0 N/P/S 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 0 0 0 0 0 0 308 00 Heat 0 0 0 0 0 00 0 00 0 0 0 0 .0 00 0 0 0 Cool 6 c) A0 excursion 0 Envelope loss/gain 0 0 0 0 0 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants 02) 230 Appliances it 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 0 0 0 0 14 15 Less external toad Less transfer Redistribution Subtotal Duct loads 0% 0 0 0 0 0 0 0 0 0 0 0% 0%0 0 0 0 0 0 0 0 0 Total room load Air required (cm) 0 0 0 0 0 0 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. RIght-Surie Residential 6.0.117 RSR29907 ACCK C:\Documents and Settingsvmemas H. EIander1Desktop‘WrIghtsoft Heat Losstennar 6008.rrp Cato. M 2010 -Aug -23 09:28:32 Page 14 PROPERTY LEGAL: O z Q DOCUMENT STANDARDS E ❑ ❑ • Registered Land Surveyor signature and company V 0 ❑ • Building Permit Applicant lir 0 ❑ • Legal description C9" 0 ❑ • Address P- 0 0 • North arrow and scale [9- 0 ❑ • House type (rambler, walkout, split w/o, split entry, lookout, etc.) 13- 0 0 • Directional drainage arrows with slope/gradient % 0 • Proposed/existing sewer and water services & invert elevation/mss S� [9' 0 0 • Street name ts/ RNV • ❑ ❑ • Driveway (grade & width - in Rand back of curb, 22' max.) Ir 0 ❑ • Lot Square Footage 0 ❑ • Lot Coverage ELEVATIONS Existing lir 0 0 • Property corners lir 0 0 • Top of curb at the driveway and property line extensions O Q' 0 • Elevations of any existing adjacent homes O 0' 0 • Adequate footing depth of structures due to adjacent utility trenches O Ce 0 • Waterways (pond, stream, etc.) Proposed 2' 0 ❑ • Garage floor C9' 0 0 • Basement floor 11- 0 0 • Lowest exposed elevation (walkout/window) C5' 0 0 • Property corners Or 0 0 • Front and rear of home at the foundation LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION Lo*z %ck 5f � 1? -V3607 pr,1.,wad turf DATE OF SURVEY: 7/21/; 0 LATEST REVISION: PONDING AREA Of applicable) ❑ [9' 0 • Easement line O Y'0 • NWL O CA-- 0 • HWL O Pr 0 • Pond # designation ❑ C9' 0 • Emergency Overflow Elevation O C]' • Pond/Wetland buffer delineation Y • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS C9" 0 0 • Lot lines/Bearings & dimensions CY 0 0 • Right-of-way and street width (to back of curb) I 0 0 • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) C9' 0 0 • Show all easements of record and any City utilities within those easements r 0 0 • Setbacks of proposed structure and sideyard setback of adjacent existing structures O CY 0 • Retaining wall requirements: Reviewed By:.„ /�(/�i ' v-6 Date 8/7,44//0G:/FORMS/Cert. of Survey Checklist Rev. 11-26-04 PIZNEERnt g"666. CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS 2422 Enterprise Drive, Mendota Heights, MN 55120, Phone: (651) 681 1914 Fax: (651) 681 9488 - Pioneereng.com Certificate of Survey for: LENNAR HOMES 3:1 Maximum Slopes ADDRESS: 3607 SPRINGWOOD COURT, EAGAN, MNar Retaining Wall Will BUYER: MODEL MODEL: SPRINGDAK ELEVATION: BBe Required LOT AREA =13,168 SO FT HOUSE AREA =2,336 SO FT SIDEWALK AREA =77 SQ FT PORCH AREA =121 SO FT DRIVEWAY AREA =1,057 SQ FT COVERAGE =27.3% BUILDING COVERAGE COVERAGE =17.7% M C0 ##3012 CP t9 CP VACANT 1.790291 4e E (897.8) 902.3 894.4 ..... ,(SP _ ---- 10 6ti+. #3011 r Alta VP #3013 owl Zal a w'- 0W� 2 cc a' ##3015 59.8 ##3016 897.7 10 895.4 -. a BENCH MARK: TOP OF SPIKE ELEV. 903.80 tiot t rn 6 ' A 4.2.3 t (9pg.8) t 903.8 33.9 45.31 �7-- 10 1 904.6 - - 0) 905.1 „ 898.1 41.83 0 (.6o 03 899.4 03/ 2.50/a�I` X 0) 0 0) d ro N % tr.O d'D/ p / Q. _ ' 2.33 O t f % - N w O 898.5 > 19.50 A901.4, Q 899.8 I O N 2 By LAGAN LNGIN ELKUvU BENCH MARK: TOP NUT HYDRANT ELEV.= ##3017 N /43 S 7 c (899.3) 899.3 92350„E EWEfl O ll ;In 0i 905.8 7.67 E 30.51-- 0 i-. 02.0-0) Cif'0 5,67 905.4 13_3 905.0 ^ Na M o aw 0 905.1 Oc Cc 2.00 cn a o Ir) a. v I 4.50-' N' 0 1 901.9 1 IO/ d N I 1-- --- _ ONI NOTE: NOTE: NOTE: NOTE: NOTE: NOTE: NOTE: NOTE: 905.1 L _ � 10 904.9 4 4. 91 (908.2) 1904.7 139, 70 VACANT UTILITIES AND CURB SHOWN ARE PROPOSED (NOT BUILT) ADD BRICK LEDGE AS REQUIRED GRADING PLAN BY LAST DATED WAS USED TO DETERMINE THE PROPOSED ELEVATIONS SHOWN ON THIS CERTIFICATE. PROPOSED BUILDING DIMENSIONS SHOWN ARE FOR HORIZONTAL LOCATION OF STRUCTURES ON THE LOT ONLY. CONTACT BUILDER PRIOR TO CONSTRUCTION FOR APPROVED CONSTRUCTION PLANS. NO SPECIFIC SOILS INVESTIGATION HAS BEEN PERFORMED ON THIS LOT BY THE SURVEYOR. THE SUITABILITY OF SOILS TO SUPPORT THE SPECIFIC HOUSE PROPOSED IS NOT THE RESPONSIBILITY OF THE SURVEYOR. THIS CERTIFICATE DOES NOT PURPORT TO SHOW EASEMENTS OTHER THAN THOSE SHOWN ON THE RECORDED PLAT. CONTRACTOR MUST VERIFY DRIVEWAY DESIGN. BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM O Oi O 0) 34.76 BENCH MARK: TOP OF SPIKE ELEV.=904.66 N O 13. 906.2 A 906.0 v V 00 v A bV CD In A LOWEST ALLOWABLE FLOOR ELEV. :(900.0) HOUSE ELEVATIONS LOWEST FLOOR ELEVATION TOP OF FOUNDATION ELEV. v LL 0 U 0 0 0 0 :(PROPOSED)/ASBUILT (901.7) (909.7) GARAGE SLAB ELEV. ® DOOR:(909.3) DENOTES TAGGED TREE X 000.00 ( 000.00 ) -�- 1000.0 1 DENOTES EXISTING ELEVATION DENOTES PROPOSED ELEVATION DENOTES DRAINAGE AND UTILITY EASEMENT DENOTES DRAINAGE FLOW DIRECTION DENOTES SPIKE DENOTES ELEVATION ON DENOTES EMERGENCY OVERFLOW WE HEREBY CERTIFY TO LENNAR HOMES THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A SURVEY OF THE BOUNDARIES OF: LOT 2, BLOCK 5, STONEHAVEN 1ST ADDITION DAKOTA COUNTY, MINNESOTA (This legal description will become volid upon filing the plot STONEHAVEN 1ST ADDITION.) IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN, AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 20TH DAY OF JULY, 2010 SCALE : 1 INCH = 30 FEET 4981 110162001 3D MTWx2 REVISED: NOTE: 7-29-10 STAKE SIGNE 13Y: Peter ONEER ENGINEERING, P.A. C . Hawkinson License No. 42299 City of aau Address: 3607 Springwood Ct Zip: 55123 Permit #: 95656 The following items were / were not completed at the Final Inspection on: r!%/ 3 Final grade - 6" from siding Permanent steps — Garage Permanent steps — Main Entry Permanent Driveway Permanent Gas Retaining Wall or 3:1 Max Slope Sod / Seeded Lawn Trail / Curb Damage Porch iteyns— Lower Level Finish Deck Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. mkL Building Inspector: G:\Building Inspections\FORMS\Checklists City of Eaaafl 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675-5675 Fax: (651) 675-5694 Use BLUE or BLACK Ink r L For Office Use Permit #: Permit Fee: .°° Date Received: MSI 13 Staff: 2013 RESIDENTIAL PLUMBING PERMIT APPLICATION Date: l I t 13 Site Address: 31-41 5 f I' a)(1. Tenant: Resident/Owner Contractor Type of Work Permit Type Name: cr Phone: Suite #: q161. ill I 5q31 Address / City / Zip: '3V' 5 Name:c� .Cf ' OV Address: .31-f 40 3L*' Pi*._551 State: Zip: ContactLIT 1 AM.T mNEn. MM aiNt City: 'I) Phone: 1/5 ? Lp[ Email: anik.iatir New _ Replacement_ Repair _ Rebuild _ Modify Space __ Work in R.O.W. Description of work �����("�'JV' c b/'tel ,. 1 RESIDENTIAL Water Heater Lawn Irrigation (= RPZ / PVB) Septic System New Abandonment Water Softener Add Plumbing Fixtures ( Main / Water Turnaround Lower Level) RESIDENTIAL FEES: $60.00 Minimum Water Heater, Water Softener, or Water Heater and Softener (includes $5.00 State Surcharge) $60.00 Lawn Irrigation (includes $5.00 State Surcharge) $60.00 Add Plumbing Fixtures, Septic System Abandonment, Water Turnaround* (includes $5.00 State Surcharge) *Water Turnaround (add $200.00 if a 5/8" meter is required) $105.00 Septic System New ($10.00 per as built) (includes County fee and $5.00 State Surcharge) TOTAL FEES $ U'V CALL BEFORE YOU DIG. Call Gopher State One CaII at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. wwN.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval an Applicant's Printed Name FOR OFFICE USE Required Inspections: Under Ground _Rough -In _Air Test _Gas Test _Final Reviewed By: Date: 30 Pilot Knob Road Eagan MN 55122 Phone; (651) 675-5675 Fax: (651) 675-5694 2015 RESIDENTIAL Date. "�'' Site Address. BUILDING PERMIT APPLICATION Unit #: Res den Owner Address / City /Zip: applicant is= Owner Contractor Tye t Work Description of work. i t jet f > Construction Cost Company: the prole+ License #: is exempt from lead Iyer se ex air) why COMPLETE THIS AREA ONLY IF CONSTRUCTINC`s A N BUILDING st 12 months, has the City of Eagan issued a permit for a simlt t plan based on a ma ply Yes No If yes, date and address of master pian: used Plumber; Phone: tractor; Phone: ater Contractor: Phone: Suppression Contractor: Phone: _.. NOTE: Plans and supporting d€t the information may be class!fi GALL BEFORE YOU DIG. Call Gopher Stace One ; before you intend to dig to receive locates of underground v hereby acknowledge that this talon -nation is complete and a Eagan; that I understand this is not a permit, but only an ap accordance with the approved plan in the case of work which req Exterior work authorized by a buiifing perm days of Applicant's P 2 for p tate; Che work w U a permit, and nd approv mite �.PA 14 Na pt SUB TYPES Foundation Single Family Multi 01 of Piex WORK TYPES Addition dK Alteration Replace Retaining Wall DESCRIPTION Valuation Plan Review (25% 100°f Census Code # of Units # of Buildings Type of Construction 36;c7 f; deed 04. DO NOT WRIfE BELOW THIS LINE Fireplace _ Garage 4. Deck Lower Level Porch (3 -Season) Porch (4 -Season) Porch (ScreenlGa t o1Pergolai Poo interior Irrnprove ant Move Building. Fire Repair Repair REQUIRED INSPECTIONS Footings (New Building) ic Footings (Deck) Footings (Addition) Foundation' Roof: __ice & Water Final Framing Fireplace: Rough In Air T Insulation Sheathing Sheetrock Fire Wails Braced Walls Reviewed By: RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Copies na Ra Occupancy Code Edition Zoning Stories Square Feet vws Egress Window *Demoiiiion of entire ifu Fin /O67 - Deoiish iuilding' Demolish interior Demolish Foundation _ Water Damage give PGA handout MCES System SAC Units City `Water Booster Pump PRV Fire Suppr Meter Size: Final / C.O. Required Final J No C.O. Required HVAC Gas Service Test Gas Line Air Test Pool: Footings .._Air/Gas Tests Final Drain Tile Siding: _Stucco Lath _Stone Lath Brick Windows Retaining Will. Radon Contr Fire Suppression: Erosion Control Other: Building Mspecto Rough in Backfi TOTAL nwc/ti crfaie\- g 3 6, /'/f Pa s PLT EF1 e CIVIL ENGINEERS" LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS 2422 EntetprIse Drive, Mendota Heights, MN 55120, Phone: (651) 681 1914 Pelt: (651) 611 9411 -Pioneemeng.com Certificote of Survey for: LENNAR HOMES 31 ADDRESS: 3607 SPRINGWOOD COURT, EAGAN, IMiNOI BUYER: MODEL MODEL: SPRINGDAK ELEVATION:, a A w LOT AREA =13,168 50 FT HOUSE AREA =2,336 SO FT SIDEWALK AREA -77 SO FT PORCH AREA •121 S0 FT DRIVEWAY AREA =1,057 50 FT COVERAGE =27.3% BUILDING COVERAGE COVERAGE -17.7% 1a a N. t479°Z9, 1 VACANT BENCH MARK: TOP OF SPIKE ELEV. =903.80 (0 0 O O S79' 44.9 (9084) s0+.7 vtiv fi 139 ' 7o 4, 7 EWE!)\ BENCH MARK: TOP OF SPIKE ELEV,=904.66 VACANT a; J AN _ NG1 _ 111, BENCH MARK: TOP NUT HYDRANT ELEV,= NOTE: NOTE: NOTE: NOTE: NOTE: NOTE. UTILITIES AND CURB SHORN ARE PROPOSED (NOT R{J117) ADO BRICK LEDGE AS REOUIRED GRADING PLAN BY LAST DATED WAS USED TO DETERMINE THE PROPOSED ELEVATIONS SHORN ON THIS. CERTIFICATE. PROPOSED BUILDING DIMENSIONS SN01WI ARE FOR HORIZONTAL LOCATION CW STRUCTURES ON THE LOT ONLY. CONTACT BUILDER PRIOR 10 CONSTRUCTION FOR APPROVED CONSTRUCTION PLANS. NO SPECIFIC SOILS INVESTIGATION HAS BEEN PERFORMED ON THIS LOT BY THE SURVEYOR. THE SUITABILITY OF SOILS TO SUPPORT THE SPECIFIC HOUSE PROPOSED 15 NOT THE RESPONSIBILITY Orr THE SURVEYOR. T1w5 CER11FICATE DOES NOT PURPORT TO SHOW EASEMENTS OTHER TNN THOSE SHOW ON THE RECORDED PLAT. NOTE: CONTRACTOR MUST VERIFY DRIVEWAY DE51GN. NOTE: BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM LOWEST ALLOWABLE FL HWUS1E ELEVATIONS LOWEST FLOOR ELEVATION ELEV, : (900.0) : (PROPOSED)/AS(3UILT (901.7) TOP OF FOUNDATION ELEV. : (.7) GARAGE SLAB ELEV. 0 POOR • (909,3) DENOTES TAGGED TREE X TES EIRSING ELEVATION 5 PROPOSED ELEVATION TES DRAMATIS AND UTRJTY EASEMENT DRAINAGE FLOW DIRECTION S SPIKE ELEVATION ON EMERGENCY OVERFLOW WE HEREBY CERTIFY TO LENNAR HOMES THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A SURVEY OF THE BOUNDARIES OF: LOT 2, BLOCK 5, STONEHAVEN 1ST ADDITION` DAKOTA COUNTY, MINNESOTA (This legol description willbecome valid upon filing the plot STONEHAVEN 1ST ADDITION.) IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS. EXCEPT AS SHOWN, AS SURVEYED BY ME OR UNDER MY DIRECT SUPERVISION THIS 20TH DAY OF JULY, 2010. ` REVISED NOTE: SCALE : 1 INCH = 30 FEET 110162001. 3D MTWx2 t0 ST SIGN BY: ER ENGINEERING, P.A, Peter'd. Han License No. 42299