4928 Whispering Way - Energy Code Compliance LtrNew Construction Energy Code Compliance Certificate
Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside
the building. The certificate shall be completed by the builder and shall list information and values of
components listed in Table N1101.8.
Mailing Address of the Dwelling or Dwelling Unit
4928 Whispering Way P %Oi
City
Date Certificate Posted
10/5/10
Eagan, MN
Nance of Residential Contractor
Vennehjem Building Corp.
MN License Number
20108964
RECEIVED
OCT 06z010
nnehjem
® BUILDING CORPORATION "--,-,'•
THERMAL ENVELOPE
RADON SYSTEM
Insulation Location
Total R -Value of all Types of
Insulation
Type: Check All That Apply
X
Passive (No Fan)
Non or Not Applicable
Fiberglass, Blown
Fiberglass, Batts
Foam, Closed Cell
Foam Open Cell
Mineral Fiberboard
Polyisocyanurate
Rigid, Isocynurate
Domestic Water Heater
Active (With fan and monometer or
other system monitoring device)
Other Please Describe Here
Below Entire Slab
Fuel Type
X
Electric
Electric
Passive
Manufacturer
Lennox
Rheem
Lennox
Foundation Wall
R10
Model
G71MPP-36C-090
82V52-2
XC14-036-230-03
Interlocked with exhaust device.
Describe:
X
t ur in
BTUS:
Interior
Perimeter of Slab on Grade
52
X
3
Other, describe:
Structure's Calculated
Heat Loss:
84,561
Heat Gain:
Rim Joist (Foundation)
R13.4
Efficiency
AFUE or
HSPF%
95
X
SEER:
14
Calculated
cooling load:
27,168
Interior
Rim Joist (1t Floor+)
R13.4
" round duct OR
Mechanical Ventilation System
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Select Type
X
" metal duct
Combustion Air Select a Type
X
Not required per mech. code
Interior
Wall
R19
Heat Recover Ventilator (HRV) Capacity in cfins:
Low:
X
High:
214
Other, describe:
Energy Recover Ventilator (ERV) Capacity in dins:
Ceiling, flat
R44
High:
X
Loca ion of duct or system:
Continuous exhausting fan(s) rated capacity in dins:
Location of thn(s), describe:
Ceiling, vaulted
R38
X
" round duct OR
Total ventilation (intennittent + continuous) rate in cfins:
" metal duct
Bay Windows or cantilevered areas
X
Room over garage
R40
X
X
2.. sprayed foam + R30 blown or Batt Insul.
Describe other insulated areas
Windows & Doors
Heating or Cooling Ducts Outside Conditioned Spaces
Average U -Factor (excludes skylights and one door) U:
0.28
X
Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):
0.43
R -value
MECHANICAL SYSTEMS
Make-up Air Selecta Type
Appliances
Heating System
Domestic Water Heater
Cooling System
X
Not required per mech. code
Fuel Type
Natural Gas
Electric
Electric
Passive
Manufacturer
Lennox
Rheem
Lennox
Powered
Model
G71MPP-36C-090
82V52-2
XC14-036-230-03
Interlocked with exhaust device.
Describe:
Rating or Size
t ur in
BTUS:
88,000
Capacity in
Gallons:
52
Output in
Tons:
3
Other, describe:
Structure's Calculated
Heat Loss:
84,561
Heat Gain:
27,168
Location of duct or system:
Efficiency
AFUE or
HSPF%
95
SEER:
14
Calculated
cooling load:
27,168
Cfin's
" round duct OR
Mechanical Ventilation System
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Select Type
" metal duct
Combustion Air Select a Type
X
Not required per mech. code
Passive
X
Heat Recover Ventilator (HRV) Capacity in cfins:
Low:
170
High:
214
Other, describe:
Energy Recover Ventilator (ERV) Capacity in dins:
Low:
High:
Loca ion of duct or system:
Continuous exhausting fan(s) rated capacity in dins:
Location of thn(s), describe:
Cfin's
Capacity continuous ventilation rate in dins:
" round duct OR
Total ventilation (intennittent + continuous) rate in cfins:
" metal duct
NOTE: Furnace model # changed due to zoned heat
Created by BAM version 052009
New Construction Energy Code Compliance Certificate
RECEIVED
Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside
the building. The certificate shall be completed by the builder and shall list information and values of
components listed in Table N1101.8.
Date Certificate Posted
n t ���5 F /�
10/5/10
O C 1 0 6 2U 10
veU��e_
Mailing Address of the Dwelling or Dwelling Unit
4928 Whispering Way �'git�l/ i # 94/9/5"Eagan,
City
MN
Name of Residential Contractor
Vennehjem Building Corp.
MN License Number
20108964
THERMAL ENVELOPE
RADON SYSTEM
Insulation Location
Total R -Value of all Types of
Insulation
Type: Check All That Apply
X
Passive (No Fan)
Non or Not Applicable
Fiberglass, Blown
Fiberglass, Batts
Foam, Closed Cell
Foam Open Cell
Mineral Fiberboard
Polyisocyanurate
Rigid, Isocynurate
Active ( With fan and monometer or
other system monitoring device)
Other Please Describe Here
Below Entire Slab
X
Foundation Wall
R10
X
Interior
Perimeter of Slab on Grade
X
Rim Joist (Foundation)
R13.4
X
Interior
Rim Joist (1° Floor+)
R13.4
X
Interior I
Wall
R19
X
Ceiling, flat
R44
X
Ceiling, vaulted
R38
X
Bay Windows or cantilevered areas
X
Room over garage
R40
X
X
2" sprayed foam + R30 blown or Batt Insul.
Describe other insulated areas
Windows & Doors
Heating or Cooling Ducts Outside Conditioned Spaces
Average U -Factor (excludes skylights and one door) U:
0.28
X
Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):
0.43
R -value
MECHANICAL SYSTEMS
Make-up Air Select a Type
Appliances
Heating System
Domestic Water Heater
Cooling System
X
Not required per mech. code
Fuel Type
Natural Gas
Electric
Electric
Passive
Manufacturer
Lennox
Rheem
Lennox
Powered
Model
G71MPP-36C-090
2V52-2
XC14-036-230-03
Interlocked with exhaust device.
Describe:
Rating or Size
BTUS:
8,000
Capacity in
Gallons:
52
Output in
Tons:
3
Other, describe:
Structure's Calculated
Heat Loss:
84,561
Heat Gain:
27,168
Location of duct or system:
,.�
Efficiency
AFUE or
HSPF%
95
SEER:
14
Calculated
cooling load: '
27,168
Cfm's
" round duct OR
Mechanical Ventilation System
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Select Type
" metal duct
Combustion Air Select a Type
X
Not required per mech. code
Passive
X
Heat Recover Ventilator (HRV) Capacity in cfins: '
Low:
170
High:
214
Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfins:
Low:
High:
Location of duct or system:
Continuous exhausting fan(s) rated capacity in cfins:
Location of fan(s), describe:
Cfin's
Capacity continuous ventilation rate in cfins:
" round duct OR
Total ventilation (intermittent + continuous) rate in cfms:
" metal duct
NOTE: Furnace model # changed due to zoned heat
Created by BAM version 052009