Loading...
4928 Whispering Way - Energy Code Compliance LtrNew Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Mailing Address of the Dwelling or Dwelling Unit 4928 Whispering Way P %Oi City Date Certificate Posted 10/5/10 Eagan, MN Nance of Residential Contractor Vennehjem Building Corp. MN License Number 20108964 RECEIVED OCT 06z010 nnehjem ® BUILDING CORPORATION "--,-,'• THERMAL ENVELOPE RADON SYSTEM Insulation Location Total R -Value of all Types of Insulation Type: Check All That Apply X Passive (No Fan) Non or Not Applicable Fiberglass, Blown Fiberglass, Batts Foam, Closed Cell Foam Open Cell Mineral Fiberboard Polyisocyanurate Rigid, Isocynurate Domestic Water Heater Active (With fan and monometer or other system monitoring device) Other Please Describe Here Below Entire Slab Fuel Type X Electric Electric Passive Manufacturer Lennox Rheem Lennox Foundation Wall R10 Model G71MPP-36C-090 82V52-2 XC14-036-230-03 Interlocked with exhaust device. Describe: X t ur in BTUS: Interior Perimeter of Slab on Grade 52 X 3 Other, describe: Structure's Calculated Heat Loss: 84,561 Heat Gain: Rim Joist (Foundation) R13.4 Efficiency AFUE or HSPF% 95 X SEER: 14 Calculated cooling load: 27,168 Interior Rim Joist (1t Floor+) R13.4 " round duct OR Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type X " metal duct Combustion Air Select a Type X Not required per mech. code Interior Wall R19 Heat Recover Ventilator (HRV) Capacity in cfins: Low: X High: 214 Other, describe: Energy Recover Ventilator (ERV) Capacity in dins: Ceiling, flat R44 High: X Loca ion of duct or system: Continuous exhausting fan(s) rated capacity in dins: Location of thn(s), describe: Ceiling, vaulted R38 X " round duct OR Total ventilation (intennittent + continuous) rate in cfins: " metal duct Bay Windows or cantilevered areas X Room over garage R40 X X 2.. sprayed foam + R30 blown or Batt Insul. Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U -Factor (excludes skylights and one door) U: 0.28 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.43 R -value MECHANICAL SYSTEMS Make-up Air Selecta Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Natural Gas Electric Electric Passive Manufacturer Lennox Rheem Lennox Powered Model G71MPP-36C-090 82V52-2 XC14-036-230-03 Interlocked with exhaust device. Describe: Rating or Size t ur in BTUS: 88,000 Capacity in Gallons: 52 Output in Tons: 3 Other, describe: Structure's Calculated Heat Loss: 84,561 Heat Gain: 27,168 Location of duct or system: Efficiency AFUE or HSPF% 95 SEER: 14 Calculated cooling load: 27,168 Cfin's " round duct OR Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type " metal duct Combustion Air Select a Type X Not required per mech. code Passive X Heat Recover Ventilator (HRV) Capacity in cfins: Low: 170 High: 214 Other, describe: Energy Recover Ventilator (ERV) Capacity in dins: Low: High: Loca ion of duct or system: Continuous exhausting fan(s) rated capacity in dins: Location of thn(s), describe: Cfin's Capacity continuous ventilation rate in dins: " round duct OR Total ventilation (intennittent + continuous) rate in cfins: " metal duct NOTE: Furnace model # changed due to zoned heat Created by BAM version 052009 New Construction Energy Code Compliance Certificate RECEIVED Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Date Certificate Posted n t ���5 F /� 10/5/10 O C 1 0 6 2U 10 veU��e_ Mailing Address of the Dwelling or Dwelling Unit 4928 Whispering Way �'git�l/ i # 94/9/5"Eagan, City MN Name of Residential Contractor Vennehjem Building Corp. MN License Number 20108964 THERMAL ENVELOPE RADON SYSTEM Insulation Location Total R -Value of all Types of Insulation Type: Check All That Apply X Passive (No Fan) Non or Not Applicable Fiberglass, Blown Fiberglass, Batts Foam, Closed Cell Foam Open Cell Mineral Fiberboard Polyisocyanurate Rigid, Isocynurate Active ( With fan and monometer or other system monitoring device) Other Please Describe Here Below Entire Slab X Foundation Wall R10 X Interior Perimeter of Slab on Grade X Rim Joist (Foundation) R13.4 X Interior Rim Joist (1° Floor+) R13.4 X Interior I Wall R19 X Ceiling, flat R44 X Ceiling, vaulted R38 X Bay Windows or cantilevered areas X Room over garage R40 X X 2" sprayed foam + R30 blown or Batt Insul. Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U -Factor (excludes skylights and one door) U: 0.28 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.43 R -value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Natural Gas Electric Electric Passive Manufacturer Lennox Rheem Lennox Powered Model G71MPP-36C-090 2V52-2 XC14-036-230-03 Interlocked with exhaust device. Describe: Rating or Size BTUS: 8,000 Capacity in Gallons: 52 Output in Tons: 3 Other, describe: Structure's Calculated Heat Loss: 84,561 Heat Gain: 27,168 Location of duct or system: ,.� Efficiency AFUE or HSPF% 95 SEER: 14 Calculated cooling load: ' 27,168 Cfm's " round duct OR Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type " metal duct Combustion Air Select a Type X Not required per mech. code Passive X Heat Recover Ventilator (HRV) Capacity in cfins: ' Low: 170 High: 214 Other, describe: Energy Recover Ventilator (ERV) Capacity in cfins: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfins: Location of fan(s), describe: Cfin's Capacity continuous ventilation rate in cfins: " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct NOTE: Furnace model # changed due to zoned heat Created by BAM version 052009