3080 Eagandale Pl - Braun Intertec Testing Report, BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6' x 12" Cylinder Dare: July 29, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Braun Interaec corpomtion 6950 West 146th Sheet, Suite 131 Apple Valley, Minnesota 55124-8520 612,431-493 Fax: 4313084 Engineers and Scientists Serving the Built and Natural Environments Project Number: 130DX-96-164C Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Fagan, Minnesota Number: 7 Mix Design: 4062 e Cast: 7/19/96 Supplier: Cemstone le Cast: 1:30 p.m. Specified Air: not specified assured Slump: 3'A" Specified Strength: 4000 tsured Air- not given Truck or Ticket No. : 73 Icr ete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM aid Added at Site: none Iple Location: 10: Inside-C9/Outside of Bldg. 5.5, 7 and 8.5; A Line-8, 10, 11; D Line-10,11,12 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 7A 7/24 7/26 5 2 7 87800 28.36 3100 B Specified Strength at 28 Days (psi): 4000 Remarks: B: The 7-day test result projects that the specified strength will likely be met at the 28-day age according to a typical strength age relationship. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Braun Intertec Corporation Mr. Doug Ohde; Taylor Ball, L.C. G r?::C°VEDDi J rs=uelson 96161Cbonc.7 F U16 n 2 1996 tfir --------------- BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6' a 12" Cylinder Date: July 29, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 8 Mix Design: 4062 e Cast: 7/22/96 Supplier. Cemstone re Cast: 2:15 p.m. Specified Air: not specified asured Slump: 4" Specified Strength; 4000 asured Air: not given Truck or Ticket No. : 354 rcrete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM uid Added at Site: none aple Location: Transformer pad Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 8A 7/24 7126 2 5 7 99170 28.27 3510 B Specified Strength at 28 Days (psi): 4000 Remarks: B: The 7-day test result projects that the specified strength will likely be met at the 28-day age according to a typical strength age relationship. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Obde; Taylor Ball, L.C. Braun Intertec Corporation M. Samuelson Manager 9616 0conc.8 . BRAUN' INTERTEC c: Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: July 29, 1996 Client: W. Joel IDisart Farm Bureau Life Insurance 5400 University Avenue West DesMomes, Iowa 50266 Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 9 Mix Design: 3067 e Cast: 7/22/96 Supplier: Cemstone re Cast: 1:15 P.M. Specified Air: not specified asured Slump: 33/4" Specified Strength: 3000 asured Air: Sot given Truck or Ticket No. : 77 tcrete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM uid Added at Site: none aple Location: Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 9A 7124 7/26 2 5 7 102070 28.27 3610 F Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. W. Jim Miller; Brooks-Borg-Skiles Arch. Engineering W. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96164C\=c.9 Braun Intertec Corporation J M. Samuelson fficeManager BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6' a 12" Cylinder Date: July 22, 1996 Client: Mr. Joel Elisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Braun Intertec Corporation 6950 West 146th Street, Suite 131 Apple Valley, Minnesota 55124-8520 612,431-4493 Fax: 431-3084 Engineers and Scientists Serving the Built and Natural Environments Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35F and Lone Oak Road Eagan, Minnesota Number: 1 Milt Design: 3067 Cast: 7/11/96 Supplier: Cemstone ie Cast: 2:00 P.M. Specified Air: n/a Isured Slump: 3" Specified Strength: 3000 Isured Air: n/a Truck or Ticket No. : 61 icrete Temperance: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM uid Added at Site: none tple Location: Footings: Line 4 going south around the corner to A Line Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) lA 7/18 7118 7 0 7 112780 28.31 3980 F Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Braun Intertec Corporation Mr. Joe Voeis; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. /Jones C -Z loei? M. Samuelson ffice Manager 961640==.1 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39,19'x 12" Cylinder Date: July 22, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Mhmesota Number: 2 Mix Design: 3067 e Cast 7/12/96 Supplier: Cemstone ie Cast: 2:00 p.m. Specified Air: n/a asured Slump: 4" Specified Strength: 3000 asured Air: n/a Truck or Ticket No. : 118 taste Temperature: not given Cylinders Per Set 3 Temperature: not given Under Cast By: MRM uid Added at Site: none aple Location: Footings: From Line A going north to Line 7 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 2A 7/18 7/19 6 1 7 90333 28.28 3190 F Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Jim Miller; Brooks-Borg-Sidles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Obde; Taylor Ball, L.C. Braun Intertec M. Samuelson Manager 961610cnncl BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: July 22, 1996 Client: Mr. Joel Iflisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number: BODX-96-164C Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 3 Mix Design: 3067 e Cast: 7/15/96 Supplier: Cemstone ie Cast: 1:30 p.m. Specified Air: n/a 3sured Slump: 3W Specified Strength: 3000 ssured Air: n/a Truck or Ticket No.: 62 icrete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM uid Added at Site: none aple Location: Footings: Line 7 to Line 12 going north (west side) and west side Line 10 to 12 Notes: Sample Date Test Field Lab Test Max Load CA Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 3A 7/18 7/22 3 4 7 92540 28.29 3270 F Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96164C\conc.3 Braun Intertec Corporation r? J M. Samuelson ffice Manager BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, G' x 12" Cylinder Date: July 24, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, /Minnesota Number: 4 Mix Design: 3067 e Cast: 7/16/96 Supplier: Cemstone a; Cast: 1:15 p.m. Specified Air: not specified asured Slump: 23/4" Specified Strength: 3000 asured Air: not given Truck or Ticket No. : 256 tcrete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM uid Added at Site: none role Location: West side: Line 5 to 10 line L Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Clue Age (pounds) (sq in) Strength, psi Code(s) 4A 7/18 7/23 2 5 7 105910 28.31 3740 F Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Braun Intertec Corporation Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. J es M. Samuelson &1ce Manager 96164C1conc.4 0 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: July 25, 1996 Project Number: BODX-96-1640 Client: Mr. Joel Khsart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Fagan, Minnesota Number: 5 Mix Design: 3067 Cast: 7/17/96 Supplier: Cemstone e Cast: 1:30 p.m. Specified Air: not specified issued Slump: 2%" Specified Strength: 3000 tsured Air: not given Truck or Ticket No. : 354 icrete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM aid Added at Site: none tple Location: 6 Pads: Inside building - C9, C7 and C5; Outside building - Line 8.5, 7 and 5.5 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Clue Cure Age (pounds) (sq in) Strength, psi Code(s) 5A 7/19 7124 2 5 7 111810 28.31 3950 F Specified Strength at 28 Days (psi): 3000 Remarics: F: The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Braun Inteztec Corpo Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Bail, L.C. J es M. Samuelson ffrce Manager 96I64C\cona5 B RAU N'm INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: July 25, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 6 Mix Design: 3067 e Cast: 7118/96 Supplier: Cemstone to Cast: 1:00 P.M. Specified Air: not specified asured Slump: 344" Specified Strength: 3000 asured Air: not given Truck or Ticket No .: not given Crete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM uid Added at Site: none note Location: 10 Piers: Inside--C5,C7,C9; Outside--D Line-1,2,3 .4 and A Line-1,2,3,4 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 6A 7/22 7/25 4 3 7 93820 28.33 3310 F Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96I64C\o=c.6 Bratm Jnwriec Corporation M. Sam n jr s ce Managekh, BRAUN' I NTE RTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6' a 12" Cylinder Date: August 12, 1996 Project Number. BODX-96-164C Client: Mr. Joel Klisatt Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Constr utim Testing Services Mmnmm Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Wimesom Number: 2 Mix Design. 3067 e Cast: 7/12/96 Supplier: Cemstone ie Cast: 2:00 p.m. Specified Air. u/a assured Slump: 4' Specified Strength: 3000 asured Air: n/a Truck or Ticket No. : 118 icrete Temperature: not given Cylinders Per Set 3 Temperature: not given inch Cast By: MRM uid Added at Site: none rple Location: Footings: From Line A going north to Line 7 Notes: Sample No. Date Recvd Test Date Field Cure Lab Care Test Age Max Load (pounds) Cyl Area (sq in) Compressive Remarks Strength, psi Code(s) 2A 7118 7/19 6 1 7 90333 28.28 3190 F 2B 7/18 8/9 6 22 28 121560 28.28 4300 K Specified Strength at 28 Days (psi): 3000 Retosrlts: F: The specified 28-day strength was met at the 7-day age acoording to the above test results. Y. The above 28-day test result meets the required design strength. c: W. Tim Miller Brooks-Borg-Skiles Ards. Engineering Braun Intertec Corporation Mr. Joe Voeis; City of Eagan W. Doug Ohde; Taylor Ball, L.C. ames M. Samuelson Office Manager 961640mx.2 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6' a 12" Cylinder Date: September 9, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 12 Mix Design: 4001 e Cast: 8/7/96 Supplier: Cemstone 1e Cast: 7:15 a.m. Specified Air: not specified asured Slump: 344" Specified Strength: 4000 asured Air: not given Truck or Ticket No. : 275 lcrete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM uid Added at Site: none mle Location: Center of floor P and D near 5 Line columns Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 12A 8/8 8/14 1 6 7 129840 28.31 4590 F 12B 8/8 914 1 27 28 158750 82.31 5610 K Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K The above 28-day test result meets the required design strength. C* Mr. Jim Nfiller; Brooks-Borg-Sales Arch. Engineering W. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96164C\conc.12 Braun Intertec Corporation 9ffi M . Samuelson ce Manager BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6' a 12" Cylinder Date: September 9, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMomes, Iowa 50266 Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 13 Mix Design: 4001 Cast: 818/96 Supplier: Gemstone e Cast: 7:15 am. Specified Air: not specified isured Slump: 4" Specified Strength: 4000 inured Air: not given Truck or Ticket No. : 253 crete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM aid Added at Site: none lple Location: South end of Line 2 floor pad Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 13A 819 8/15 1 6 7 127250 28.31 4490 F 13B 8/9 96 1 27 28 152830 28.31 5400 K Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result meets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec Corporation M. Samuelson Manager 961640\ c.13 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: September 9, 1996 Project Number: BODX-96-1640 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center interstate 35E and Lone Oak Road Fagan, Minnesota Number: 14 Mix Design: 4001 Cast 8/9196 Supplier: Cemstone e Cast: 7:15 am. Specified Air: not specified isrced Slump: 444" Specified Strength: 4000 tsured Air: not given Truck or Ticket No. : 358 icrete Temperature: not given Cylinders Per Set: 3 Temperance: not given inder Cast By: MRM aid Added at Site: none tple Location: Center between Lines 5 and 9 floor pad Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 14A 8/12 8/16 3 4 7 147730 28.28 5220 F 14B 8/12 916 3 25 28 168710 28.30 5960 K Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result meets the required design strength. c: Mr. Tim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Braun Intertec Corporation Mr. Doug Ohde; Taylor Ball, L.C. J M. Samuelson ffice Manager 96164C\c .l4 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, P z 12" Cylinder Braun Intertec Corporation 6950 West 146th Skeet, Suite 131 Apple Valley, Minnesota 551248520 612-431.4493 Fox: 431,3084 Engineers and Scientists Serving the Built and Natural Environments Date: August 16, 1996 Project Number: BODX-96-1640 Client Mr. Joed Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMomes, Iowa 50266 Project Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number. 4 Mix Design: 3067 e Cast: 7116/96 Supplier: Cemstone Ie Case: 1:15 p.m. Specified Air. not specified asured Slump: 234" Specified Strength: 3000 asured Air: not given Truck or Ticket No .: 256 mete Temperature: not given Cylinders Per Set 3 Temperature: not given finder Cast By: MRM uid Added at Site: none ante Location: West side: Line 5 to 10 lime Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 4A 7118 7123 2 5 7 105910 28.31 3740 F 4B 7118 8/13 2 26 28 127350 28.30 4500 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result meets the required design strength. c: Mr. Tim Miller; Brooks-Borg-Sldbes Arch. Engineering Braun lamUc C Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. e -/± es M. Samu V efice Manager 96164C1conc.4 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, tl x 12" Cylinder Date: August 16, 1996 Project Number: BODX-96-1640 Client: Mr. Joel imsart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 5 Mix Design: 3067 e Cast: 7/17/96 Supplier. Cemstone ie Cast: 1:30 p.m. Specified Air, not specified tsured Slump: 2%" Specified Strength: 3000 asured Air. not given Truck or Ticket No. : 354 mete Temperature: not given Cylinders Per Set 3 Temperature: not given inder Cast By: MRM uid Added at Site: none mule Location: 6 Pads: Inside building - C9, C7 and C5; Outside building - Line 8.5, 7 and 5.5 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 5A 7/19 7124 2 5 7 111810 28.31 3950 F 5B 7/19 8114 2 26 28 133100 28.31 4700 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. ir The above 28-day test result meets the required design strength. c: W. 8m NUer; Brooks-Borg-Skiles Arch. Engineering Braun Intertec Corporation Mr. Joe Vicels; City of Eagan Mr. Doug Obde; Taylor Ball, L.C. amen M, nelson Office Manager 9et6acuooa5 BRAUN'" INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a IT' Cylinder Date: August 17, 1996 Project Number: BODX-96-1640 Client: Mr. Joel 10isart Farm Bureau Life Insurance 5400 University Avenue West DesMoioes, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota FIELD DATA. DESIGN DATA: Set Number. 6 Mix Design: 3067 Date Cast: 7/18/96 Supplier. Cemstone Time Cast: 1:00 P.M. Specified Air not specified Measured Slump: 3%" Specified Strength: 3000 Measured Air. not given Track or Ticket No. : not given Concrete Temperance: not given Cylinders Per Set: 3 Air Temperance: not given Cylinder Cast By: N" Liquid Added at Site: none Sample Location: 10 Piers: Inside-C5,C7,C9; Outside-D Line-1,2,3 ,4 and A Line-1,2,3,4 Field Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Care Cure Age (pounds) (sq in) Strength, psi Code(s) 6A 7122 7a5 4 3 7 93820 28.33 3310 F 6B 7122 8/15 4 24 28 116790 28.31 4130 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result meets the required design strength. c Mr. Tim Miller; Brooks-Borg-Sidles Arch. Engineering Braun lowrtec Corporation Mr. Joe Voels; City.of Eagan Mr. Doug Ohde; Taylor Ball, L.C. es M. en,nnrtum 6/16ffice Manager 961640wnc.6 BRAUN INTERTEC Compressive Test of Concrete Cylinder Test Method- ASTM C 39, 6" z IT' Cylinder Dan;; August 17, 1996 Project Number: BODX-96.1640 Project Client Mr. Joel Misat Farm Bureau Life Insurance 5400 University Avenue West DesMomes, Iowa 50266 Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Fagan, /Minnesota FIELD DATA. DESIGN DATA: Set Number: 7 lvfix Design: 4062 Date Cast: 7/19/96 Supplier: Cemstone Ti ni Cast: 1:30 p.m. Specified Air: not specified Mooned Slump: 3%" Specified Strength: 4000 Measured Air: not given Track or Ticket No. : 73 Concrete Temperature: not given Cylinders Per Set 3 Air Temperature: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: 10: Inside-C9/Outside of Bldg. 5.5, 7 and 8.5; A Line-8, 10, 11; D Line-10,11,12 Field Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (ponds) (sq in) Strength, psi Code(s) 7A 7/24 7/26 5 2 7 87800 28.36 3100 B 7B 7/24 8/16 5 23 28 115650 28.28 4090 X Specified Strength at 28 Days (psi): 4000 Retnerl s: B: The 7-day rest result projects that the specified strength will likely be met a the 28-day age according to a typical strength age relationship. K The above 28-day test result meets the required design strength. Q Mr. Jim Miller, Brooks-Borg-Sidles Arch. Engineering scan Inocrec Corporation Mr. Joe Voels; City. of Eagan Mr. Doug Ohde; Taylor Ball, L.C. qap,4??Z- r Samuelson M. Manager %1640conc.7 BRAUN' INTERTEC CompreWve Test of Concrete Cylinder Test Method: ASTM C 39, V :12" Cylinder Date: August 20, 1996 Project Number: BODX-96-1640 Client Mr. Joel Rlisat Farm Bureau Life Insurance 5400 University Avenue West DesMoiaes, Iowa 50266 Project Description: Construction Testing Services Mimesota Farm Bureau Center Interstate 35E and Lone Oak Road Fagan, Minnesota FIELD DATA: DESIGN DATA. Set Number: 8 Mix Design: 4062 Date Cast: 7122!96 Supplier: Cemstone Time Cast: 2:15 p.m. Specified Air: not specified Measured Slump: 4- Specified Strength: 4000 Measured Air: not given Truck or Ticket No. : 354 Concrete Temperature: not given Cylinders Per Set: 3 Air Temperature: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: Transformer pad Field Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 8A 7124 7126 2 5 7 99170 28.27 3510 B 8B 7/24 8119 2 26 28 123930 28.50 4348 K Specified Strength at 28 Days (psi): 4000 Remarks: B: The 7-day test result projects that the specified strength will likely be met at the 28-day age according to a typical strength age relationship. K: The above 28-day test result meets the required design strength. C. Mr. Jim Miller Brooks-Borg-Sidles Arch. Mr. Joe Voels; City of Eagan Mr. Doug Oltde; Taylor Ball, L.C. 96164C\w=.8 Engineering Braun Intettec Corporation awes WSamuelson Office Manager BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: August 20, 1996 Project Number: BODX-96-1640 Client: Mr. Jed Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Intestate 35E and Lone Oak Road Eagan, Minnesota FIELD DATA: DESIGN DATA: Sur Number: 9 Mix Design: 3067 Date Cast 7/22/96 Supplier. Cemstone Time Cast 1:15 P.M. Specified Air not specified Measured Slump: 31:" Specified Strength; 3000 Measured Air: 3ot given Truck or Ticket No. : 77 Concrete Temperature: not given Cylinders Per Set 3 Air Temperance: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: Field Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Care Age (pounds) (sq in) Strength, psi Code(s) 9A 7/24 7/26 2 5 7 102070 28.27 3610 F 9B 7/24 8/19 2 26 28 134320 28.50 4713 K Specified Strength at 28 Days (psi): 3000 Remarks: F: ne specified 28-day strength was met at the 7-day age according to the above test results. K: The above 28-day test result meets the required design strength. c: Mr. rum Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Braun hutertee Corporation Mr. Doug Obde; Taylor Ball, L.C. 9f M. Sam Manager 96164(.ticonc.9 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: August 16, 1996 Project Number. BODX-96-1640 Client Mr. Joel lOisart Farm Bureau We Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number. 10 Mix Design: 4001 e Cast 8/6/96 Supplier. Cemstone to Cast: 9:30 am. Specified Air am specified asuced Slump: 334" Specified Strength: 4000 asured Air: not given Truck or Ticket No. : 191 Crete Temperature: not given Cylinders Per Set 3 Temperature: not given Bader Cast By: MRM ptid Added at Site: none mile Location: North end line 9 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Circe Cure Age (pounds) (sq in) Strength, psi Code(s) 10A 818 8113 2 5 7 135590 28.30 4790 F Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 2&-day strength was met at the 7-day age according to the above test results. c: Mr. Tim Miller Brooks-Borg-Sales Arch. Engineering Mr. Joe Voeis; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec M. Same Manner 96164C%C=.10 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, B' z 12" Cylinder Date: August 16, 1996 Project Number: BODX-96-1640 Client Mr. Joel Slisart Farm Bureau Life Insurance 5400 University Avenue west DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center laterstate 35E and Lone Oak Road Fagan, Minnesota FIELD DATA: DESIGN DATA: Set Number: 11 Mix Design: 4001 Date Cast 816!96 Supplier: Cemstone Time Cast 7:10 am. Specified Air: not specified Measured Slump: 444^ Specified Strength: 4000 Measured Air: not given Track or Ticket No .: 263 Concrete Temperature: not given Cylinders Per Set 3 Air Temperature: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: North end of floor line 12 Field Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 11A 818 8/13 2 5 7 134200 28.30 4740 F Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was stet at the 7-day age according to the above test results. C. Mr. Am Miller, Brooks•Borg-Skiles Arch. Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96164L- o C.11 Engineering Braun Intertec Corporation M. Samuelson r 91rice Manager BRAUN' NTE RTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: August 16, 1996 Project Number: BODX-96-1640 Client Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing. Services Nfimesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, bilmiesota Number: 12 Mix Design: 4001 Cast 8/7196 Supplier. Cemstone 0 Cast: 7:15 a.m. Specified Air: not specified mured Slump: W Specified Strength: 4000 rsured Air: not given Truck or Ticket No.: 275 lcrete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM uid Added at Site: none wle Location: Center of floor P and D near 5 Line columns Notes: Sample Date Test Field Lab Test Max Load Cyi Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 12A 8/8 8114 1 6 7 129840 28.31 4590 F Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Tun Miller Brooks-Borg-@dles Arch. Engineering W. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 961640=nc.12 BRAUN' INTERTEC Compresdve Test of Concrete Cylinder Test Method ASTM C 39, 6" a 12" Cylinder Date: August 17, 1996 Project Number: BODX-96.1640 Client: Mr. Joel Klisart Form Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Nfmnasota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota FIELD DATA DESIGN DATA: Set Number: 13 Mix Design: 4001 Date Cast: 818/96 Supplier. Cemstone Time Cast: 7:15 am. Specified Air: not specified Measured Slump: 4" Specified Strength: 4000 Measured Air: not given Truck or Ticket No. : 253 Concrete Temperatm'e: not given cylinders Per Set: 3 Air Temperance: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: South end of Line 2 floor pad Field Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 13A 819 8115 127250 28.31 4490 Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. r. Mr. Jim Miller, Brooks-BorgSldles Arch. Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Engineering Brain Inter= Corporation H M. Samuelson Office Manager 96164Ckonc.13 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: August 17, 1996 Project Number: BODX-96.1640 Client: Mr. Joel laisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Fagan, Minnesota Number: 14 Mix Design: 4001 e Cast: 819/96 Supplier: Cemstone ie Cast: 7:15 a.= Specified Ain not specified tsured Slump: 4%- Specified Strength: 4000 asured Air not given Truck or Ticket No .: 358 tcrete Temperaaae: not given Cylinders Per Set: 3 Tempersuire: not given inch Cast By: MRM uid Added at Site: none nine Location: Center between Lines 5 and 9 floor pad Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 14A 8112 8/16 3 4 7 147730 28.28 5220 F Specified Strength at 28 Days (psi): 4000 Remarks: R The specified 28-day strength was met at the 7-day age according to the above test results. c: Mr. Tun Miller; Brooks-Borg-Stales Arch. Engineering Mr. Joe Voels; City of Eagan Braun Intertec Mr. Doug Ohde; Taylor Ball, L.C. lia'Em M. Sam ffice Manager 961e40moos.14 BRAUN' I NTE RTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 17 Cylinder Bmun Intertec Corporation 6950 West 146th Street, Suite 131 Apple Valley, Minnesota 551248520 612-431-4493 Fax: 431-3084 Engineers and Scientists Seeing the Built and Natural Environments Date: August 12, 1996 Project Number: BODX-96-1640 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMomes, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E ad Lone Oak Road Eagan, Minnesota Number: 3 Mix Design: 3067 e Cast 7/15/96 Supplier: Cemstone e Cast: 1:30 p.m. Specified Air: n/a asmed Slump: 3%" Specified Strength: 3000 astaed Air: n/a Truck or Ticket No. : 62 tctete Temperature: not given Cylinders Per Set 3 Tempera me: not given inder Cast By: MRM uid Added at Site: none apse Location: Footings: Line 7 to Line 12 going north (west side) L and west side Line 10 to 12 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 3A 7/18 7/22 3 4 7 92540 28.29 3270 F 3B 7/18 8112 3 25 28 111640 28.29 3950 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result meets the required design strength. C* Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 961640wac.3 Bratm haertBc corporation Tailaes M. Samuelson ffice Manager BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, C x 12" Cylinder Braun Intertec Corporation 6950 West 146th Street, Suite 131 Apple Valley, Minnesota 55 1 24-85 20 612-431-4493 Fax: 4313084 Engineers and Scientists Serving the Built and Natural Environments Date: August 12, 1996 Project Number: BODX-961640 Client: Mr. Joel laism Farm Bureau Life Iasarmce 5400 University Avenue West DesManes, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota FELD DATA: DESIGN DATA: Set Number: 1 Mix Design: 3067 Date Cast: 7/11196 Supplier. Cemstone Time Cast: 2:00 p.m. Specified Air: n/a Measured Slug: 3" Specified Strength: 30M Measured Air: n/a Truck or Ticket No. : 61 Concrete Temperature: not given Cylinders Per Set: 3 Air Temperature: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: Footings: Line 4 going south around the corner to A Line Field Notes: Sample Dam Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 1A 7/18 7/18 7 0 7 112780 28.31 3980 F 1B 7118 8/8 7 21 28 145380 28.29 5140 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result meets the required design strength. C.* Mr. Jim Miller; Brooks-Borg-Skiles Arch. Eagmecring Braun Intertec Corporation Mr. Joe Voeis; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. J es M. Samuelson A? Manager 96164C1conc.l BRAUN" Special Inspector Daily Report Page of INTERTEC City ofF-66iftN Md Report Number: r Date of This Report: '7-119 Project Name: MrANA/F-SOTif FA;IM Project No.: B9 Dkc1I?-)??L Project Address: Ln d ?e ANA E}fa R N ?I F P r-f7t'i Client: Client Project No.: Weather: SV NA)Y h+uM I Temperature: Type of Inspection: Inspection Coverage: ? Continuous ? Masonry Rebar Placement ? Foundations Periodic ? Welding ? Concrete Placement ? Fireproofing ? Bolting ? Tendon Placement ? Other Did the architect or engineer authorize thanes to city ap proved plans? Yes ? (Listed Below) No Description and location of work completed: c rt1=? KF 5olL--h SF-L-e tv AND R&gRR l N rvORTH r-oo-QU& F-W GR) b POW-25 6--ia T-d D -12 L Hr (A1 E ? REB Ak oF r o b.vMN5 f }T 7t}E FOL_tr9wrtill? GRID PO/N175 ; f}-? ?IT-Tye-?4A-9,r?- }O-ol,0-3, b pEE16P IVC.C' F 0 U 0 riDNIS I.Pr (i PLAA/ DATED Juivr , 191(( List tests performed: • Are there any discrepancies noted from this day's observations? Yes ? No • Are there any outstanding discrepancies on this project? Yes ? No • If yes, see attached Summary Sheet. To the best of our knowledge, work inspected was done in accordance with the approved plans, specifications and applicable workmanship provisions of the UBC, except as noted above. / Signed:C 1.4s Date: -7 Print Full Name: 12A Vi 0) W. J1957-ES I.D. Number: -7 967Lf 3 (white copy to Braun Intertee file. Blue copy to General Contractor.) inn\specinsp 4 1/25195 BRAUN` INTERTEC Report Number: Project Name: Project Address: Client: Weather: Special Inspector Daily Report Page -L- of City of FA,,',/+N M ty (o Date of This Report: 7 --/9-c!(0 M/NNE4r77h FARM 60a, 4u Project No.: LOA, E- (VAk Alk0 F A6,4A/QAt-F PLALF Client Project No.: PARTLY G. r-a v b Y Temperature: 7 Q° Type of Inspection: Inspection Coverage: El Continuous 13 Masonry / ^ LS Rebar Placement ? Foundations Periodic ? Welding ? Concrete Placement ? Fireproofing ? Bolting ? Tendon Placement ? Other Did the architect or engineer authorize changes to cit y approved plans? Yes ? (Listed Below) No Description and location of work completed: r-Hgr NFD SOlL-4 BE/ o W Mlb PESA W GOLVM AZ S Flr GA I D PoIti7TS $-a ,8-3, 8-1? /3- 5-06-a C-3 r- -`F Ai-So fgEc,1rFQ RF 6A-R c s ~ F CoLuml^ A t G R i D Po/,v7-5 A-11, , -10 /4-f, LO LIZ-, V-/1Z AND I-H5 -3 cU75,106 r4j5 gMrRRAvci-? m/vl Si AA Pt-AN PRrE List tests performed: Are there any discrepancies noted from this day's observations? Yes ? No Are there any outstanding discrepancies on this project? Yes ? No If yes, see attached Summary Sheet. To the best of our knowledge, work inspected was done in accordance with the approved plans, specifications and applicable workmannshhiip, ?provisions of the UBC, except as noted above. Signed: cl?u ?.o+ ?/Y krLC9a Date: 7-/2-% Print Full Name: DAVID W )(957-8 5 I.D. Number: 770 N'3 (Whire copy to Braun lntertec file. Blue copy to General Conrractor.) 1'rm\spc,insp.4 1/25/95 BRAUN" INTERTEC Report Number: Project Name: Project Address: Client. Special Inspector Daily Report city of rzA& M A/ Page _, )_ of I Date of This Report: M/avNeseri4 FARM iykgAU -Project No.: AIDN,Cl47 --M;4C, LONE OA'If A V6 EA&,W6AL,,E PL.Ag-E Client Project No.: Weather: $ U/VA/Y Temperature: Type of Inspection: Inspection Coverage: ? Continuous ? Masonry d Rebar Placement ? Foundations Periodic ? Welding ? Concrete Placement ? Fireproofing ? Bolting ? Tendon Placement ? Other Did the architect or engineer authorize changes to city approved plans? Yes ? (Listed Below) No Description and location of work completed: CNE-( Kf0 50/45 BELOW COLUMN P/t65 ?rT- GRID Pe/tiT5 l(2c. I/-- J I II - B, lD-8? 2-8,1-6- 11*Pat.7ED RF_8 hR p1_& amFA1r -rot 5,fM1: hi--So Glf ?c? TRANSFoR MER PRI) NEAR NoRT4v?&_5T c-oRNEP -Or- i8VII-D1A1t2, REr e:ksm ;; Fe)u,o0A-1-toX1 Stf}lj pi.AN DfiT? J?NC _ /'f cn r List tests performed: FEI?roRMEO GOM P/i'G7-DA/ 7 B5T/ /1/& nF ?MrFRIOR BAe,kPlLL- oAi FgyA14 -r/OA/ vyA--L'5 1}rA6 coc.vMA/ ftta5 • Are there any discrepancies noted from this day's observations? Yes ? No Ed • Are there any outstanding discrepancies on this project? Yes ? No ? • If yes, see attached Summary Sheet. To the best of our knowledge, work inspected was done in accordance with the approved plans, specifications and applicable iI44workmanship /provisions of the UBC, except as noted above. Signed: d?antii„i °1V Var1 CDA Date: 7-37rl6 Print Full Name: AAv 16 W J05 TE5 I.D. Number: 7 `/O 43 (White copy to Braun Intertec file. Blue copy to General Contractor.) irm\spc6nsp.4 1/25/95 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: August 12, 1996 Project Number: BODX-96-1640 Client: Mr. Joel K lisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 1 Mix Design: 3067 Cast 7111/96 Supplier: Cemstone e Cast: 2:00 p.m. Specified Air: n/a inured Slump: 3" Specified Strength: 3000 inured Air: n/a Truck or Ticket No. : 61 icrete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM aid Added at Site: none cple Location: Footings: Line 4 going south around the comer to A Line Notes: Sample Dare Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Dare Cure Cure Age (pounds) (sq in) Strength, psi Code(s) IA 7/18 7/18 7 0 7 112780 28.31 3980 F 1B 7/18 8/8 7 21 28 145380 28.29 5140 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K: The above 28-day test result meets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Braun Intertec Corporation Mr. Doug Ohde; Taylor Ball, L.C. J es M. Samuelson Affice Manager 963NCkonc.l BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: August 12, 1996 Project Number: BODX-96-164C Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 2 Mix Design: 3067 e Cast: 7/12/96 Supplier: Cemstone C Cast: 2:00 p.m. Specified Air: n/a tsured Slump: 4" Specified Strength: 3000 cured Air: n/a Truck or Ticket No .: 118 lcrete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM uid Added at Site: none iple Location: Footings: From Line A going north to Line 7 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 2A 7/18 7/19 6 1 7 90333 28.28 3190 F 2B 7/18 8/9 6 22 28 121560 28.28 4300 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was suet at the 7-day age according tu the above test results. K: The above 28-day test result tweets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Braun Intettec Corporation Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. amen M. Samuelson Office Manager 9616dC\conc.2 BRAUN'" INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 12" Cylinder Date: August 12, 1996 Project Number: BODX-96-1640 Client: Mr. Joel IOisatt Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Set Number: 3 Date Cast: 7/15196 Time Cast: 1:30 p.m. Measured Slump: 354" Measured Air: n/a Concrete Temperature: not given Air Temperature: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: Footings: Notes: Mix Design: 3067 Supplier: Cemstone Specified Air: n/a Specified Strength: 3000 Truck or Ticket No. : 62 Cylinders Per Set: 3 Line 7 to Line 12 going north (west side) and west side Line 10 to 12 Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 3A 7/18 7/22 3 4 7 92540 28.29 3270 F 3B 7/18 8/12 3 25 28 111640 28.29 3950 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result tweets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Sidles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96164C\c nc.3 Braun Intertec Corporation /Jaiiies M. Samuelson ffice Manager BRAUNS" INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: January 7, 1997 Project Number: BODX-96-164C Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 4 Mix Design: 3067 Cast: 7/16196 Supplier- Cemstone ie Cast: 1:15 P.M. Specified Air: not specified Isured Slump: 23/4" Specified Strength: 3000 isured Air: not given Truck or Ticket No. : 256 icrete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MRM uid Added at Site: none Wle Location: West side: Line 5 to 10 line Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 4A 7/18 7/23 2 5 7 105910 28.31 3740 F 4B 7/18 8113 2 26 28 127350 2830 4500 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K: The above 28-day test result meets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96164C%conc.4 Braun Intertec Corporation Ja es M. Samuelson ce Manager BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: January 7, 1997 Project Number: BODX-96-164C Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota A: Number: 5 Mix Design: 3067 Z Cast: 7/17/96 Supplier: Cemstone to Cast: 1:30 p.m. Specified Air: not specified asured Slump: Thf Specified Strength: 3000 asured Air: not given Truck or Ticket No. : 354 rcrete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM uid Added at Site: none rple Location: 6 Pads: Inside building - C9, C7 and C5; Outside building - Line 8.5, 7 and 5.5 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 5A 7/19 7/24 2 5 7 111810 28.31 3950 F 5B 7/19 8/14 2 26 28 133100 28.31 4700 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-clay strength was met at the 7-day age according to the above test results. K: The above 28-day test result meets the required design strength. c: Mr. Jim Miller, Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec M. Samuelson Manager 96164C1com.5 BRAUN' I NTE RTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: January 7, 1997 Project Number, BODX-96-164C Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota FIELD DATA: DESIGN DATA: Set Number: 6 Mix Design: 3067 Date Cast: 7/18/96 Supplier: Cemstone Time Cast: 1:00 P.M. Specified Air: not specified Measured Slump: 31k" Specified Strength: 3000 Measured Air: not given Truck or Ticket No. : not given Concrete Temperature: not given Cylinders Per Set: 3 Air Temperature: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: 10 Piers: hiside--C5,C7,C9; Outside-D Line-1,2,3, 4 and A Line-1,2,3,4 Field Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 6A 7/22 7/25 4 3 7 93820 28.33 3310 F 6B 7/22 8/15 4 24 28 116790 28.31 4130 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K: The above 28-day test result meets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec M. Samuelson Manager 96164Ckonc.6 , BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: January 7, 1997 Project Number: BODX-96-164C Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 7 Mix Design: 4062 Cast: 7/19/96 Supplier. Cemstone e Cast: 1:30 p.m. Specified Air: not specified tsured Slump: 3'fr" Specified Strength: 4000 tsured Air: not given Truck or Ticket No. : 73 icrete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM aid Added at Site: none rple Location: 10: Inside-C9/Outside of Bldg. 5.5, 7 and 8.5; A Line-8, 10, 11; D Line-10,11,12 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 7A 7/24 7/26 5 2 7 87800 28.36 3100 B 7B 7/24 8/16 5 23 28 115650 28.28 4090 K Specified Strength at 28 Days (psi): 4000 Remarks: B: The 7-day test result projects that the specified strength will likely be met at the 28-day age according to a typical strength age relationship. K: The above 28-day test result meets the required design strength. c: Mr. Tim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec M. Samu Manager 96I64Clcanc.7 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: January 7, 1997 Project Number: BODX-96-164C Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota A: c: Number: 8 Mix Design: 4062 e Cast: 7/22196 Supplier. Cemstone to Cast: 2:15 p.m. Specified Air: not specified asured Slump: 4" Specified Strength: 4000 asured Air: not given Truck or Ticket No.: 354 tcrete Temperature: not given Cylinders Per Set: , 3 Temperature: not given inder Cast By: MRM uid Added at Site: none aple Location: Transformer pad Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 8A 7124 7126 2 5 7 99170 28.27 3510 B 8B 7/24 8/19 2 26 28 123930 28.50 4348 K Specified Strength at 28 Days (psi): 4000 Remarks: B: The 7-day test result projects that the specified strength will likely be met at the 28-day age according to a typical strength age relatiouship. K: The above 28-day test result meets the required design strength. Mr. Jim Miller; Brooks-Borg Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 96164C1conc.8 Braun Intertec Corporation BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" x 12" Cylinder Date: January 7, 1997 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number. BODX-96-164C Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number. 9 Mix Design: 3067 e Cast: 7/22/96 Supplier: Cemstone ie Cast: 1:15 P.M. Specified Air: not specified isured Slump: 3'A" Specified Strength: 3000 asured Air: 3ot given Truck or Ticket No.: 77 icrete Temperature: not given Cylinders Per Set: 3 Temperature: not given finder Cast By: MPM uid Added at Site: none rple Location: Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 9A 7/24 7126 2 5 7 102070 28.27 3610 F 9B 7124 8/19 2 26 28 134320 28.50 4713 K Specified Strength at 28 Days (psi): 3000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K. The above 28-day test result meets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec M. Samuelson Manager 96164C1conc.9 BRAUN I NTE RTEC Report of Field Compaction Tests Date: October 14, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoiness. Iowa 50266 arvun Interlec Corporation 6950 West 146th Street, Suite 131 Apple Valley, Minnesota 551248520 612.431-4493 Fax: 4313084 Engineers and Scientists Serving the Built and Natural Environments Project: BODX-96-164C Report: 3 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan. Minnesota est ate ype Soil ID and Classifilatton Optimum Moisture* (%) Max. Lab Dry Density* (Std.Proc.) (pcfj Inpiace Moisture (96) Inplace Dry Density (pcf) Relative Compaction Specified Minimum Compact. omments 9 7/16/96 N P-2: ML 161% 1091h 8 108 99 95 A 10 7/16/96 N P-2: ML 161/2 1091h 7 105 96 95 A 11 7/17/96 N P-2: ML 161h 1091h 11 104 95 95 A 12 7/17/96 N P-2: ML 161/2 1091h 5 104 95 95 A Key: N = Nuclear, ASTM D 2922 A = Test results comply with specifications. SC = Sand Cone, ASTM D 1556 B = Test results do not comply with specifications. * = O.M. and M.L.D.D. rounded to nearest 0.5 Test Test Location Elevation 9 20'N, 40'E of NE building corner (watermain) 896 10 30'S, 40'E of NE building corner (waterma±n) 8951h 11 Column Pad, west of Grid Point 8-D 899 12 Column Pad, west of Grid Point 6-D 899 Elevation Reference: c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec M. Samuelson Manager 96164c1es.3 BRAUN' INTERTEC Report of Field Compaction Tests Date: October 14, 1996 Client: Mr. Joel Rlisart Farm Bureau Life Insurance 5400 University Avenue nya r,e..X.r..;.... r....,. CMAr Project: BODX-96-164C Report: 4 Project Description: Construction Testing Services Mmnesota Farm Bureau Center Interstate 35E and Lone Oak Road ra"n minnt!cnta est ate ype Soil ID and Classification Optimum Mokmm.* (5a) Max. Lab Dry Denny (Std.Prw-) (pcf) Inplace Moisture (%) Inplace Dry Density (pc[) Relative Compaction Specified Minimum Compact. omments N P-2: ML 16'% 109'/2 5 112 102 95 A N P-2: ML 16'h 109'h 4 110 100 95 A N P-2: ML 16'% 109th 9 105 96 95 A 16 7/22/96 t N P-2: ML 16% 109'% 9 112 102 95 A L Key: N = Nuclear, ASTM D 2922 SC = Sand Cone, ASTM D 1556 = O.M. and M.L.D.D. rounded to nearest 0.5 A = Test results comply with specifications- B = Test results do not comply with specifications. Test Test Location Elevation 13 20'N, 3'W of SE building corner (interior foundation backfill) 902'h 14 70'N, 3'E of SW building corner (interior foundation backfill) 902'% 15 15'E of NW building corner (interior foundation backfill) 9021/2 16 Column Pad Backfill at grid lines (interior foundation backfill) 902'% Elevation Reference: C Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Inteztec nnc?? - M. Samuelson Manager 96164ckU.4 BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, 6" a 1T' Cylinder Date: September 9, 1996 Client Mr. Joel Ica= Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Braun Interfec Corpora ion 6950 West 146th Street, Suite 131 Apple Valley, Minnesota 55124-8520 612-431-4493 Fax: 431-3084 Engineers and Scientists Serving the Built and Natural Environments Project Number: BODX-96-1640 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Set Number: 10 Date Cast: 8/6196 Tune Cast: 9:30 am. Measured Slump: 33/4" Measured Air: not given Concrete Temperature: not given Air Temperature: not given Cylinder Cast By: MRM Liquid Added at Site: none Sample Location: North end line 9 Notes: Design: 4001 lier: Cemstone lfied Air: not specified ified Strength: 4000 k or Ticket No. : 191 Iders Per Set: 3 Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 10A 8/8 8/13 2 5 7 135590 28.30 4790 F 10B 8/8 9/3 2 26 28 146640 28.29 5180 K Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was met at the 7-day age awarding to the above test results. K The above 28-day test result meets the required design strength. C'. Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 961640coac.10 Braun Intertec Corporation M. Samuelson Office Manager BRAUN' INTERTEC Compressive Test of Concrete Cylinder Test Method: ASTM C 39, G' x 12" Cylinder Date: September 9, 1996 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Number: BODX-96-164C Project Description: Construction Testing Services Minnesom Farm Bureau Center Interstate 35E and Lone Oak Road Eagan, Minnesota Number: 11 Mix Design: 4001 Cast: 8/6/96 Supplier: Cemstone e Cast: 7:10 a.m. Specified Air: not specified tsured Slump: 4%" Specified Strength: 4000 tsured Air: not given Truck or Ticket No.: 263 icrete Temperature: not given Cylinders Per Set: 3 Temperature: not given inder Cast By: MRM uid Added at Site: none tple Location: North end of floor line 12 Notes: Sample Date Test Field Lab Test Max Load Cyl Area Compressive Remarks No. Recvd Date Cure Cure Age (pounds) (sq in) Strength, psi Code(s) 11A 818 8/13 2 5 7 134200 28.30 4740 F 11B 8/8 9/3 2 26 28 139180 28.29 4920 K Specified Strength at 28 Days (psi): 4000 Remarks: F: The specified 28-day strength was met at the 7-day age according to the above test results. K: The above 28-day test result meets the required design strength. c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. 961640couc.11 Braun Intm= Corporation J M. Samuelson ffice Manager r BRAUN INTERTEC Laboratory Compaction Characteristics of Soil (Proctor) Date: July 8, 1996 Project: BODX-96-164C Client: Description: Mr. Joel Klisart Construction Testing Services Farm Bureau Life Insurance Minnesota Farm Bureau Center 5400 University Avenue Interstate 35E and Lone Oak Road West DesMoines Iowa 50266 Eagaan Minnesota Field Data: Date Sampled 6/29/96 Test Number P-1 Sampled By DWJ Location Sampled Classification SM: Silty Sand, fine-grained, brown Laboratory Data: ASTM D: 698-91 Procedure: standard B Date Tested: 7/3/96 As Received Water Content: Prep. Method: wet Ran= Type: manual Sieve Data, % on 3/4": % 3/4"-3/8": % 318" - #4: Size of "Oversize": Percent Oversize: Spec. Gravity: 2.55 Curve Values Corrected Values (ASTM D 4718) Maximum Dry Unit Weight, pcf 111 pd pcf Optimum Water Content, % 14 % % 114 112 110 r eo 3 108 106 104 Ur Voids a) tame 2.55 ned) Water Content, % 10 12 14 16 18 20 96164c\p-1 BRAUN' I NTE RTEC Laboratory Compaction Characteristics of Soil (Proctor) Date: July 8, 1996 Project: BODX-96-1640 Client: Description: Mr. Joel Klisart Construction Testing Services Farm Bureau Life Insurance Minnesota Farm Bureau Center 5400 University Avenue interstate 35E and Lone Oak Road West DesMoines, Iowa 50266 Eagan, Minnesota Field Data: Date Sampled 6/29/96 Test Number P-2 Sampled By DWJ Location Sampled Classification ML: Silt, fine-grained, brown Laboratory Data: ASTM D: 698-91 Procedure: standard B Date Tested: 7/2/96 As Received Water Content: Prep. Method: wet Rammer Type: manual Sieve Data, % on 314": % 314"-3/8": % 3/8" - #4: Size of "Oversize": Percent Oversize: Spec. Gravity: 2.60 Maximum Dry Unit Weight, pcf Optimum Water Content, % Curve Values Corrected Values (ASTM D 4718) 109'6 Pd Pd 16th % % ids 4.. V a ao 3 A Water Convent, % 12 14 16 18 20 22 961646p-2 BRAUN" INTERTEC Report Number: Project Name: Project Address: Client: Weather: Special Inspector Daily Report City of EAR AA/ M AI Page I of Date of This Report: 7 -1 -9(0 M 1NA( e4orA r-hkH BUREAU Project No.: R 0b-A96 -/4Lf G Client Project No.: P ,071-v r -L. d U b Y Temperature: Z 1 a Type of Inspection: Inspection Coverage: ? Continuous ? Masonry L?J Rebar Placement ? Foundations Periodic ? Welding ? Concrete Placement ? Fireproofing ? Bolting ? Tendon Placement ? Other Did the architect or engineer authorize changes to city approved plans? Yes ? (Listed Below) No Description and location of work completed: CuF4 FD F007-LAI L 5 uB(- R 4b SoILS AND RE RAR PLAcbMEAt- 2 E7'w'EP-A/ 6R1b LINES B -/ AA/A r*F- a ASTERA)MO5r EJ6E of 6Q/JC1 I-J'IE S- RfF:eAZA/GF/? FouNDAnDA//5L/9B PI-AA/ 5HSS7- 3.1 DATED (a-5`2/6 AND r_A5r AEVISED 7-1 -5(a List tests performed: Are there any discrepancies noted from this day's observations? Yes ? No Are there any outstanding discrepancies on this project? Yes ? No If yes, see attached Summary Sheet. To the best of our knowledge, work inspected was done in accordance with the approved plans, specifications and applicable workmanship provisions of the UBC, except as noted above. Signed: d?w""-J ?WaoDate: -7 -13 Print Full Name: DA U1D W. Jv5M6 I.D. Number: 7_2 0 L4 -i (White copy to Braun intertec file. Blue copy to General Contractor.) tnn\specinsp.4 1/25/45 BRAUN` INTERTEC Report Number: Project Name: Project Address Client. Special Inspector Daily Report City of r A4/ AN M N Page of _I a Date of This Report: 7-15 -quo MtNNCSdrR FAA01 RVAGA! Project No.: BW96 -/WL Ir+vE oAY AN+J oAoavP&- pt Ar-F Client Project No.: Weather: 5Ll p/N;' Temperature: -29 Type of Inspection: Inspection Coverage: / Continuous ? El Masonry ,? Id Rebar Placement El Foundations E Periodic Er ? Welding ? Concrete Placement ? Fireproofing ? Bolting ? Tendon Placement ? Other Did the architect or engineer authorize changes to city approved plans? Yes ? (Listed Below) No Description and location of work completed: 0669"E D AND PR08ED Feor+iv& 4UB&RAQE Sotl-S. 80T-r&1 w:+5 1,1F-L)JV'1 DEN56 F1N5 60 av' D SI ,.TY SfrND RLSO c FfE(kED R- 8r4R P R,0rA GRA) PetnrTj- /ANO THE. SovrµFt}5T' r-AX R or 711E R(sTReMM`o TO 1O Fr-,c--r wE57 of GRID POINT A-12 - REFGRENec recN?AtrU/1?S+f?i3 Pt?N PREPA 5D fl'{ SAO&SS &A-!ShO,ARa a4l`5 4ND DArf5fl c)N1F 1 nett, List tests performed: Are there any discrepancies noted from this day's observations? Yes ? No Are there any outstanding discrepancies on this project? Yes ? No If yes, see attached Summary Sheet. To the best of our knowledge, work inspected was done in accordance with the approved plans, specifications and applicable workman n shippp rovisions of the UBC, except as noted above. Signed: Og ( Date: -7'l5-y(o Print Full Name: DRv 1 D 14, ,Je STfiS I.D. Number: ? 7 Oit:5 (White copy to Braun lntertec file. Blue copy to General Contractor.) I'rm\sptcinsp.4 1/25195 BRAUN" INTERTEC Report Number: Project Name: Project Address: Client: Weather: Special Inspector Daily Report Page of City of FAG AA/ M Al 3 Date of This Report: 7 -1 to- `16 miOVESoTA FA4RM 8UAEhV Project No.: 60,0X96 -164e, Sufi CA-IV AND E (9*,VbAL-F- Client Project No.: S?NVY Temperature: V(o Type of Inspection: - Inspection Coverage: ? Continuous ? Masonry ,/ LI Rebar Placement ? Foundations d Periodic ? Welding ? Concrete Placement ? Fireproofing ? Bolting ? Tendon Placement ? Other Did the architect or eng ineer authorize changes to city approved plans? Yes ? (Listed Below) No Description and location of work completed: C_HEr kEh F& brtA/b SC,?BcQAh SOILS B©r7QM V-'1+5 M6OIvM DENSE FINF ? AAhNE4 1 1t TY 5 ?AVD f} L 5 o c tl'aeIt>?( 1 RFBr ?R >=RoM FRAM GRID Poi/VT-5- 7-0 10 dN LIAVE -0 t-hAA PRcPRALD B 4*b DA-TE-D IIANc S, 19yL List tests performed: PcAFAM6O "MA&.TJVIV 7'F-9TS CA/ Wltl- R Mfg/A/ E A57' 67P BVII-61 M(o COM PAC-rrON O IT Are there any discrepancies noted from this day's observations? Yes ? No 9 Are there any outstanding discrepancies on this project? Yes ? No If yes, see attached Summary Sheet. To the best of our knowledge, work inspected was done in accordance with the approved plans, specifications and applicable workmanship provisions of the UBC, except as noted above. Signed: ??? t_Q 4 Date: 7 -l6 -c? Print Full Name: PAV 10 W, I-M5M,7- I.D. Number: 7(: OO (White copy to Braun Inrenec file. Blue copy to General Contractor.) 1'nn\specinsp 3 IM/95 BRAUN" INTERTEC Report Number: Project Name: Project Address: Client: Weather: Special Inspector Daily Report Page of City of r-h&,4A) Mn/ L} Date of This Report: '7-17-% M/Nm5so*/f -FARM 8vRE,4& Project No.: 800%A WO Lemg OAA- AA/,o SAGAVb4LLE Pt /ham Client Project No.: c1.ou DY Temperature: 7y ° Type of Inspection: Inspection Coverage: Continuous ? ? Masonry E( Rebar Placement ? Foundations _,/ LAG Periodic ? Welding ? Concrete Placement ? Fireproofing ? Bolting ? Tendon Placement ? other Did the architect or eng ineer authorize thanes to city roved plans? Yes ? (Listed Below) No Description and location of work completed: r_HF_re,*66 So1c5 BC?ow? AND RF8A W r'tE THRFE GofvMA15' ou_r4tDE eivYRh/NLE DF Sutb-D/N6, A,10AT G211) L/V 5 SG?74?-,, AVD7c, Rer-P,zRF?GF' FouNoR--ioiv. 151-Ag8 pkhAJ VA-rF-P JVJVF- Z 19y(?' U27-F,- 7l4a COLUMN PAD5 wEke lNe-RE F_b +N 51ZE FROM 3\ x 3\ TV L Y ro A"c9mi n -rE TfIF Hook FROM 7Ha c.o1_?hN5. List tests performed: Pi;RFORMED GOM?Ae,7-01(J -LEST 6A-' La (pyyER coLumy Pt,t05 Ar Ovr51pE e1L17-RAr1cE nF Aun pl#G Are there any discrepancies noted from this day's observations? Yes ? No? Are there any outstanding discrepancies on this project? Yes ? No If yes, see attached Summary Sheet. To the best of our knowledge, work inspected was done in accordance with the approved plans, specifications and applicable workmanship provisions s of the UBC, except as noted above. Signed: 4w OV l.e vi& Date: -7 Print Full Name: iiV I A W JO 57-Erj I.D. Number: 7`/0 q 3 (White copy to Braun Interrec file. Blue copy to General Contractor.) inn\sp.6nsp.4 125/95 Farm Bureau Life Insurance Project BODX-96-1640 January 15, 1997 Page 2 deep) hand auger probes. Soil classifications were also determined by observing the hand auger probe cuttings. The excavating contractor typically removed up to 7 feet of topsoil, fill and loose silts from the building area with dozers and scrapers. Soils encountered in the excavation bottoms primarily consisted of silty sand and poorly graded sand with silt which were judged to be in a medium dense condition. The building was excavated to an approximate elevation of 899 on the north end to 9001h on the south end. The proposed building finished floor elevation is 903.5. Based on the construction staking, the oversizing achieved by the contractor was in excess of 1H: IV (one horizontal:one vertical). Engineered Fill The engineered fill was typically placed in 8 to 12 inch thick lifts with scrapers and dozers and then compacted with a large, self-propelled, vibratory sheepsfoot roller. The engineered fill consisted mainly of silt and silty sand. A total of 16 compaction tests were performed in the engineered fill placed during the site wall backfill/utilities grading. All tests met or exceeded the minimum density requirement of 95 percent of standard Proctor density (ASTM D 698). The compaction test results and Proctor curves have been previously submitted and are attached to this report. Concrete Reinforcement Concrete reinforcement special inspection observations were conducted from July 12 to July 22, 1996, by an ICBO certified special inspector for reinforced concrete. Copies of the special inspector daily report (reports 1 through 7) are attached to this report. In summary, the observed reinforcing was placed in accordance with the available plans and specifications. Concrete Placement Braun Intertec did not observe the concrete placement procedures being used for this project. A representative of Taylor Ball performed the on-site concrete testing and prepared the compressive strength test cylinders. Concrete Testing Concrete compressive strength test cylinders were picked up from the site and delivered to the laboratory for curing and compression testing. The results of the compressive strength testing were previously submitted and are attached to this report. Review of the attached 28-day test results indicate the concrete represented by the cylinders has exceeded the required minimum compressive strengths. The concrete test results were previously submitted and are attached to this report. Conclusion Based on the results of our soil borings and excavation observation, it is our opinion that the excavation bottom soils are adequate for fill and foundation support. Farm Bureau Life Insurance Project BODX-96-164C January 15, 1997 Page 3 Based on the construction staking provided by others, it appears the excavation was adequately oversized. Based on the results of the compaction tests, it appears the fill has been placed adequately for foundation and floor slab support. Based on our concrete reinforcement observations and compressive strength tests, it appears the concrete reinforcement was placed in accordance with the project plans and specifications and the compressive strength results met or exceeded the minimum strength requirements. General Services performed by the geotechnical engineers for this project have been conducted with that level of care and skill ordinarily exercised by members of the profession currently practicing in this area. No warranty, expressed or implied; is made. If you have any questions regarding the information contained in this report, please call David Jostes or Greg Bialon at (612) 431-4493. Sincerely, Wcw?C (V? David W. Jostes Senior Engineering Assistant Professional Certification: I hereby certify that this report was prepared under my direct supervision and that I am a duly Registered Professional Engineer under the laws of the State of Minnesota. Grego J. Bialon, PE Project Engineer Registration Number: 24017 Attachments: Report of Field Compaction Tests, Reports I through 4 Proctors P-1 and P-2 Special Inspector Daily Reports, Reports 1 through 7 Concrete Compressive Strength Results, Sets 1 through 9 c: Mr. Jim Miller; Brooks Borg Skiles Architecture Engineering Mr. Joe Voels; City of Eagan dwjlgjb:rib\ 64.9 ug Ohde; Taylor Ball, L.C. ' BRAUN'" INTERTEC Report of Field Compaction Tests Date: July 9, 1996 Project: BODX-96-164C Report: 1 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines, Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Fagan. Minnecnta est ate ype Soil H) and Classification Optimum Moisture* (%) Max. Lab Dry Density* (Std.Proc.) (pd) Inplace Moisture (%) Inplace Dry Density (pd) Relative Compaction (%) Specified Minimum Compact. (%) omments 1 6/29/96 N P-2: ML 16'2 109'/2 16 110 100 95 A 2 6129/96 N P-2: ML 16'2 109'/2 15 110 100 95 A 3 7/1/96 N P-1: SM 14 111 11 114 103 95 A 4 7/1/96 N P-1: SM 14 111 12 113 102 95 A Key: N = Nuclear, ASTM D 2922 SC = Sand Cone, ASTM D 1556 * = O.M. and M.L.D.D. rounded to nearest 0.5 A = Test results comply with specifications. B = Test results do not comply with specifications. Test Test Location Elevation 1 10'S, 10'E of NW building comer, floor slab subgrade 8981/2 2 15'S, 5'E of NW building corner, floor slab subgrade 901 3 40'S, 20'E of NW building comer, floor slab sub grade 903 4 20'N, 20'E of SW building comer, floor slab subgrade 903 Elevation Reference: c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Brent Cooper; Taylor Ball Braun Intertec M. Same Manager 961646as.I BRAUN' INTERTEC Report of Field Compaction Tests Date: July 9, 1996 Project: BODX-96-164C Report: 2 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue West DesMoines. Iowa 50266 Project Description: Construction Testing Services Minnesota Farm Bureau Center Interstate 35E and Lone Oak Road Vann" mi".Pentn est ate ype Soil II) and Classification Optimum Moisture* M Max. Lab Dry Density* (Std.Proc.) (pef) Inplace Moisture M Inplace Dry Density (pct) Relative Compaction (%) Specified Minimum Compact. (%) omments 5 7/2/96 N P-1: SM 14 111 10 114 103 95 A 6 712/96 N P-1: SM 14 111 11 114 103 95 A 7 7/5/96 N P-1: SM 14 111 10 116 104 95 A 8 7/5/96 N P-1: SM 14 111 12 114 103 95 A Key: N = Nuclear, ASTM D 2922 SC = Sand Cone, ASTM D 1556 * = O.M. and M.L.D.D. rounded to nearest 0.5 A = Test results comply with specifications. B = Test results do not comply with specifications. Test Test Location Elevation 5 60'N, 80'E of SE building corner (parking lot sub grade) 900'h 6 100'N, 60'E of SE building comer larking lot subgrade) 900 7 180'E of NE building comer (parking lot subgrade) 896 8 180'N, 120'E of SE building comer (parking lot subgrade) 898 Elevation Reference: c: Mr. Jim Miller; Brooks-Borg-Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Brent Cooper; Taylor Ball Braun Intertec M. Samuelson Manager 9616kkew.2 BRAUN' I NTE RTEC Report of Field Compaction Tests Date: January 7, 1997 Client: Mr. Joel Misart Farm Bureau Life Insurance 5400 University Avenue lir T WR..:--- T--... &MeZ Project: BODX-96-164C Project Description: Construction Testing Services Minnesota Farm Bureau Center interstate 35E and Lone Oak Road F?nan Minnecnfa Report: 3 est ate ype Soil ID and Classification Optimum Moisture* (%) Max. Lab Dry Density* (Std.Proc.) (pct) Inplace Moisture M Inplace Dry Density (pcf) Relative Compaction (%) Specified Minimum Compact. (%) omments 9 7/16/96 N P-2: ML 161/2 1091h 8 108 99 95 A 10 7/16/96 N P-2: ML 161h 1091/2 7 105 96 95 A 11 7117/96 N P-2: ML 161h 1091h 11 104 95 95 A 12 7/17/96 N P-2: ML 161h 109% 5 104 95 95 A F 4 - Key: N = Nuclear, ASTM D 2922 SC = Sand Cone, ASTM D 1556 * = O.M. and M.L.D.D. rounded to nearest 0.5 A = Test results comply with specifications. B = Test results do not comply with specifications. Test Test Location Elevation 9 20'N, 40'E of NE building comer (watermain) 896 10 30'S, 40'E of NE building comer (watermain) 8951/2 11 Column Pad, west of Grid Point 8-1) 899 12 Column Pad, west of Grid Point 6-1) 899 EH Elevation Reference: c: Mr. Jim Miller; Brooks-Borg Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec Corporation M. Samuelson Manager 9616Ac'xu.3 BRAUN NTE RTEC Report of Field Compaction Tests Date: January 7, 1997 Client: Mr. Joel Klisart Farm Bureau Life Insurance 5400 University Avenue Walt T)aclbfninec. Tnwa 'WMA, Project: BODX-96-164C Project Description: Construction Testing Services Minnesota Farm Bureau Center interstate 35E and Lone Oak Road FaQan_ Minnesota Report: 4 est ate ype Soil ID and Classification Optimum Moisture* M Max. Lab Dry Density* (Std.Proc.) (pct) Inplace Moisture (%) Inplace Dry Density (pcf) Relative Compaction (%) Specified Minimum Compact (%g) omments 13 7/22/96 N P-2: ML 161h 1091h 5 112 102 95 A 14 7/22196 N P-2: ML 161h 1091/2 4 110 100 95 A 15 7122/96 N P-2: ML 161h 1091h 9 105 96 95 A 16 7/22/96 N P-2: ML 16th 1091h 9 112 102 95 A Joey: N = Nuclear, ASTM D 2922 A = Test results comply with specifications. SC = Sand Cone, ASTM D 1556 B = Test results do not comply with specifications. * = O.M. and M.L.D.D. rounded to nearest 0.5 Test Test Location Elevation 13 20'N, 3'W of SE building comer (interior foundation backfill) 9021/2 14 70'N, 3'E of SW building comer (interior foundation backfill) 9021/2 15 WE of NW building comer (interior foundation backfill) 9021h 16 Column Pad Backfill at grid lines (interior foundation backfill) 902'/2 E E Elevation Reference: c: Mr. Jim Miller; Brooks-Bore Skiles Arch. Engineering Mr. Joe Voels; City of Eagan Mr. Doug Ohde; Taylor Ball, L.C. Braun Intertec M. son Manager 96164c1cm.4 y B RAU N'" INTERTEC January 15, 1997 Brown Intertec Corporation 6950 West 146th Street, suite 131 Apple Volley, Minnesota 55 1 24-85 20 612431-4493 Fax: 4313084 Engineers and scientists serving the Built and Natural Emironments Project BODX-96-1640 Z8s33 Mr. Joel Misart M u Farm Bureau Life Insurance 0?9t? PL 5400 University Avenue 3a So cy9 ?vt West Des Moines, IA 50266 /- 1 1= 4eAAt D.+L E tE A,4 Srh' Dear Mr. Klisart: Re: Summary of Excavation Observations, Compaction Testing, Concrete Testing and Concrete Steel Reinforcement Special Inspections for the Minnesota Farm Bureau Center, I-35E and Lone Oak Road, Eagan, Minnesota As authorized by Mr. Brent Cooper of Taylor Ball on June 20, 1996, Braun Intertec has performed periodic excavation observations, compaction testing, concrete testing and concrete steel reinforcement special inspections at the Minnesota Farm Bureau Center. Our work was performed in general accordance with our cost estimate dated June 5, 1996. This report provides a summary of our services. Background Information Braun Intertec Corporation (Braun Intertec) performed a geotechnical evaluation for the project. The report is dated February 26, 1996, Project BODX-96-012. We were provided with a "Grading and Drainage Plan" prepared by Westwood Professional Services, Inc., dated April 21, 1996, last revised June 21, 1996. We were also provided with a "Foundation/Slab Plan" prepared by Brooks Borg Skiles Architecture Engineering dated June 5, 1996, last revised July 1, 1996. Parking lot and building corner stakes were set in the field by Westwood Professional Services, Inc. Typically, cut or fill to establish grade was indicated on the stakes. Braun Intertec excavation oversizing measurements, bottom of excavation elevations and compaction test locations and elevations were referenced from these stakes. The location of the graded building pad and parking lot is the responsibility of Westwood Professional Services, Inc. Proposed Construction The project consists of constructing a single story, slab-on-grade structure. The structure will utilize wood and metal framing. The building will be supported by conventional spread footings designed for a soil bearing pressure not exceeding 3,000 pounds per square foot (psf). The site work will also involve construction of a parking lot to the northeast of the building. Excavation Observations The excavation observations were conducted by a senior engineering assistant from June 27 to July 5, 1996. The excavation observations consisted of observing the soils exposed in the bottom and side walls of the excavations. The approximate density or consistency of the soils encountered was estimated by judging the force required to advance random, shallow (up to 3 feet