4314 Aries Ct - Permit 95574 Special Inspection ReportMetro Roof Products
3093 `A' Industry Street
Oceanside CA 92054
Toll Frey:
(866) METRO -4U
PH: (760) 435 -9842
Order FX: (760) 435 - 1162
General FX: (760) 435 -9412
www.l'netroroofs.com
#9S 5 7z/
SPECIAL INSPECTION REPORT
INSPECTOR:
Lifetime Metal Shingles, LLC. - Dan Henkel - PH (612) 221 -9825 EX: (952) 758 -5915 - 203
Music Street, New Prague MN 56071
INSPECTION SITE:
1313 Aries court, Egan MN
ROOFING CONTRACTOR AT INSPECTION SITE:
Next Generation Contracting 6043 Hudson Road, #140 E Woodbury MN 55125 - New Century
Exteriors - Susie Case - ncesusieeaoLcom
INSTALL DETAILS AT INSPECTION SITE:
Metro panels when installed as described below and Metro's ICC ES Legacy Report ER -5626,
April Pt, 2004, Sections 2.1 - 2.8, meet the following wind design.
WIND SPEED: 90 -m.p.h - EXPOSURE: 'C' - HEIGHT- Buildings not over 40 /tin height,
The contractor on this site used screws, #10 Dia., X 2 -112" Long X W Hex Washer Head which
replaces the use of nails as stated in the ICC report.
INSPECTION DETAILS:
installation Process Qbserved- YES by Dan Henkel
Product Descron- Stone - coated steel shake roofing panel & accessories, with
exposed fasteners through the back heel & front downturn of each Metro Shake panel.
Product Name - Metro Roof Products, MetroSHAKE' Stone- Coated Steel roof panel &
accessories
Product Dimension - Overall 52- inches wide X 16- inches deep, each panel covers 50- inches
wide X 14 -1/2- inches deep
Product Steel Thickness - Steel measured at 0.017- inches
Product Fastener Type - #10 X 2-1/2-inches long X 1 /4 -inch hex washer head screws color
matched to the roof stone chip
Roof Sheathing Dimension - Exterior grade plywood V2 -inch thickness
Roof Panel Installation- Metro Roof Products, Metro Shake panels installed over the existing
asphalt shingle roof with #10 X 2 -1 /2" long 1 /4" Hex Washer Head screws that provide the
required penetration into the roof deck a minimum of 3 /4 ", The panels are fastened to the roof
deck using, a total of five (5) screws in the front downturned nose of each Metro Shake panel
and five (5) in the back horizontal flange.
P. Henkel 1 1 l ?ate- r
Inspector Date
the Vneture above certifies that theinspection details noted in this Inspection Roma have beenrollowed and the instaktion
m e e t s M e ll o i n s t a t i r e q u i r e m e n t s and t h e M e t r o ICC L e g a c y E S R e p o r t 5 6 2 8 c r i t e r i a T h i s
sae venfrcation and inspection orMe derails used.
Mr+ LE9a7-.S pecia11AauecifonReporr- PH- 1 /IZ10 ReV. 1 1/W1A 1:97 PM