Loading...
4314 Aries Ct - Permit 95574 Special Inspection ReportMetro Roof Products 3093 `A' Industry Street Oceanside CA 92054 Toll Frey: (866) METRO -4U PH: (760) 435 -9842 Order FX: (760) 435 - 1162 General FX: (760) 435 -9412 www.l'netroroofs.com #9S 5 7z/ SPECIAL INSPECTION REPORT INSPECTOR: Lifetime Metal Shingles, LLC. - Dan Henkel - PH (612) 221 -9825 EX: (952) 758 -5915 - 203 Music Street, New Prague MN 56071 INSPECTION SITE: 1313 Aries court, Egan MN ROOFING CONTRACTOR AT INSPECTION SITE: Next Generation Contracting 6043 Hudson Road, #140 E Woodbury MN 55125 - New Century Exteriors - Susie Case - ncesusieeaoLcom INSTALL DETAILS AT INSPECTION SITE: Metro panels when installed as described below and Metro's ICC ES Legacy Report ER -5626, April Pt, 2004, Sections 2.1 - 2.8, meet the following wind design. WIND SPEED: 90 -m.p.h - EXPOSURE: 'C' - HEIGHT- Buildings not over 40 /tin height, The contractor on this site used screws, #10 Dia., X 2 -112" Long X W Hex Washer Head which replaces the use of nails as stated in the ICC report. INSPECTION DETAILS: installation Process Qbserved- YES by Dan Henkel Product Descron- Stone - coated steel shake roofing panel & accessories, with exposed fasteners through the back heel & front downturn of each Metro Shake panel. Product Name - Metro Roof Products, MetroSHAKE' Stone- Coated Steel roof panel & accessories Product Dimension - Overall 52- inches wide X 16- inches deep, each panel covers 50- inches wide X 14 -1/2- inches deep Product Steel Thickness - Steel measured at 0.017- inches Product Fastener Type - #10 X 2-1/2-inches long X 1 /4 -inch hex washer head screws color matched to the roof stone chip Roof Sheathing Dimension - Exterior grade plywood V2 -inch thickness Roof Panel Installation- Metro Roof Products, Metro Shake panels installed over the existing asphalt shingle roof with #10 X 2 -1 /2" long 1 /4" Hex Washer Head screws that provide the required penetration into the roof deck a minimum of 3 /4 ", The panels are fastened to the roof deck using, a total of five (5) screws in the front downturned nose of each Metro Shake panel and five (5) in the back horizontal flange. P. Henkel 1 1 l ?ate- r Inspector Date the Vneture above certifies that theinspection details noted in this Inspection Roma have beenrollowed and the instaktion m e e t s M e ll o i n s t a t i r e q u i r e m e n t s and t h e M e t r o ICC L e g a c y E S R e p o r t 5 6 2 8 c r i t e r i a T h i s sae venfrcation and inspection orMe derails used. Mr+ LE9a7-.S pecia11AauecifonReporr- PH- 1 /IZ10 ReV. 1 1/W1A 1:97 PM