1189 Eagan Industrial Rd - Coca Cola Vending Building RTU Notice6128882587
J ?l N= 1 5- 9 7 W E D 1-4 :Z4 W E N Z E L E N G I N E E R I N G
??TEI a<=>w
Wenzel
Erzgineering
Incorporated FAX
r, Je e V aal s
Company of
Fax number _Of$ 1` 4- (42 ot 4" I0700 Morgan Ave. South
B!oomiVon, MN $5431
??!' ?'^O ? PNONE 612-868-6516
From ?i? F,4X 612•838-2587
Regarding L-OC44- C01
Number ot pages ?
(Inciudlng
cover 6heet)
N
P _ 0 1
Date WEI Job numbes 9 7Z? IZ3•O?
Remarks LAS r"Je(Z(Ck c+-A (z1.Q A+'lAr}Ct,f"S V'tr
TRAAd^I ?,I,I F.'EPOPT
h
5END Jr.TJ-15-97 1tiED 14: 16 ?
?
?
# DATE S. T. n1AP1F.. 7' II';lE PGs DTOTE DP
01 JF1H-15 14;16 8814d94 l•$'^ ? OK
0 Urgen! 0 Pleasc Commcnt U Copy Maited
6128882587
•S A N? 1 5- 9 7 W E D 1 4:3 4 W E N Z E L E N G I N E E R I N G
WEI
Wenzel
Ertgineering
Irccorporated
January 15, 1997
10100 Morgart Ave. Sauth
BloornuWon. MN 55437 Mr. Mark Pope
PxoNE612-888•6516 RLP Architeets, ItIC.
FAX 612•888•2587 2570 Hvuy. 10 Suite 14
Moundsview, MN
Re: Coca-Cola Distribution
Vending Building
2750 Eagandale Boulevard
Eagan, MN
WEI Job No.: 972-123.01
Dear Mark:
P _ 0 2
At your request, we have reviewed the existing roof framing at the above
referenced building to suppon the additional weight of two new roof-top unils
(R.T.U.'s). Our review was based on the foAowing information provided by Yale
Inc. Mechanical Contractors- ,
1. A parlial floor plan showing sketches of the proposed locations of the
new R.T.U.'s.
2. A cut sheet showing size (3'-0" x 5'-7") and weight (approximately 600
pounds) af the proposed units.
3. Information on size and spacing of existing joists. (In addition, tttis
information was verified by WEI.)
Using a fotal roof load of 60 PSF and placing the R.T.U.'s as sketched on the
partial floor plan by Yale Inc., it is our professional judgment that the existing
"26H8" roof joists are adequate to support the two additional R.T. U.'s, provided
that each R.T.U. is supported by at least two joists, and na sing(e or pair ot joists
is used to support more than one new and/or existing R.T.U.
• 612888z587
J A N= 1 S- 9 7 W E D 1 4: 3 S W E N Z E L E N G I N E E R I N G
CoCa-Cola pistribution
WEI Job No.: 972-123.01
Page 2 0£ 2
P _ 03
Please see the attached details for racommended roof opening reinforcement,
and joist panel reinfarcement. If you have any questions, or if any of tha above
intormation is incorrect, pleasa contact us.
Sincerely,
WENZEL ENGINEERING, ING.
#H "6? dzze-r
Jeffery G. Weinberger, E.I.T.
Enciosure
Wen.zet
Engineering
Irccorporated
WEI ?
??? OAw
Patricia A. Co1a, P.E.
1010QM0t$Ntdve.S •$L»i?iup:inn LIN 4,1
TELE'.l'HONE GI Z-NN8di51G • k:IX bl?•; Nh !sn.'