Loading...
4828 Steeplechase Cir 'L _74~0~0 5, 77 r. rq ~ 2007RESIDENTIAL BiTILDING rExMiT arrLicaTio City Of Eagan - 3830 Pilot Knob Road, Eagan NIN 55122 Telephone # 651-675-5675 FAX # 651-675-5694 lew ConslrucUon Re uiremenis RemodeVReoair ReoWremenls Office Use OnN 3 reqislered sile surveys showing sq. ft. of lof, sq. R of house; and all roofed areas 2 copies M plan shuxmg footinqs, beams, jasls Cert o( Survey Reoi. ~K ~N 0 manimum lot mverage allowed) 1 set of Energy Calculafions forheated addNons Soils RepoR -Y._N (20/o 1 Soils Report if proposed buildiig is lo be placed on tlislurbetl soil 1 site survey for addifbns 8 decks Tree Pres PWn Recd _Y ?2 copies of plan showing beam 8 window sizes; poured found desgn, elc. Add'tlion -indcate 8amsde septic sysfem Tree.Pres Required : _Y !'.N v1 sel of Energy Calculations On-Sile Sep6c System Y_ N Ri ~ copies of Tree Preservation PWn if lot plaHed after 711193 ym Joisl Detml OpUons seleclion sheef (buBdings wiN 3 or less uniLS) ,/N6nnegasco mechanical ventilation fortn Plans are considered ublic information unless ou state the are trade secret and the reason. Q Q~ Da[e Ce/ ~ Construction Cost ~ ~ Site Address UniUSte :5- 'S1, ~i i~ Description of Work ~ ~C""' ' " Multi-Family Bldg ~ Y - N Fireplace(s) _ 0 J( 1 J 2 Property Owoer -T?~> 1 Telephone # ( ) Contractor ~ Address CitY State Zip ,22_ Telephone # z COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING - - Minnesota Rules 7670 Cateeorv 1 _ Minnesota Rules 7672 Energy Code Category • Residential Ven6lation Calegory i Worksheet • New Energy Code Worksheet (Jsubmissiontype) Submitted Submittetl • Energy Envelope Calculations Submitted In the I st 12 monihs, has ihe City of Eagan issued a permit for a similar plan V on a~asTe~ pl 8 Y N If yes, date a d address of master plan: ~y t LicensedPlumber Tlr Telephone#('~'03) Mechanical Contractor Tlephone #(G1Z) OZS _ Sewer/Water Contracior phone #((sy) U I hereby apply for a Residential Building Perm' nd1~L`k 1 that the information is complete and accurate; that the work will be in confonnance with the ordinances and codes of the City of Eagan and the State of MN Statutes; I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the app4Applica he case of work which requires a review and a roval of 1 ns. PP 6 ~'P , ApplicanPs Printed Name gnature !•I .c 7~ (o DO NOT WRITE BELOW THIS LINE ' Sub Tvaes . ? 01 Foundation ? 07 05-plex ? 13 76-plex 20 Pool . ? 30 Accessory Bldg ? 02 SF Dwelling ? OB 06-plez ? 16 Fireplace ? 21 Porch (3-sea.) ? 31 Ezt. Alt - Multi ? 03 Ot of._ plex ? 09 07-plex 17 Garage ? 22 Porch/Addn. (4-sea.) ? 33 Ext. Alt- SF ? 04 02-plex ? 10 OS-plex ? 18 Deck ? 23 Porch (screenlgazebolpergola) ? 36 Multi Misc. /1"T OS 03-pfex O 11 10-plex ? 19 Lower Level ? 24 Storm Damage ? 06 04-plex ? 12 12-plex ? 25 Miscellaneous W rk T es 31 New ? 35 Int Improvement ? 38 Demolish Intenor ? 44 Siding ? 32 Addition ? 36 Move Building ? 42 Demolish Foundation ? 45 Fire Repair ? 33 Alteration ? 37 Demoiish Building' ? 43 Reroof ? 46 Windows/Doors ? 34 Replacemenf •Demolition (Entire Bldg) - Give PCA handout to applicant DBSCrIDtioO: Water Damage _ Yes Valuation 1131 e2'~' Occupancy , MCES System PlanReview 100%or~25% Census Code T(Oi Zoning City Water SAC Units Stories OBooster Pump # of Units Sq. Ft. ~L) PRV # of Bldgs Length Fire Sprinklered T Type of Const Width REQUII2ED INSPECTIONS ~ Footings (new bldg) . Sheetrock _ Footings (deck) 1( FinaUC.O. Footings (addition) Final/No C.O. ,~w Foundation _ HVAC _ Drain Tile Other Roof Ice & Wa[er Final Pool Ftgs Air as Tests Final ~ Framing _ Siding _ Stucco Lath Y tone La _Brick ~ Fireplace ~ R.I. XAirTest ~C Final - Windows r~~ Insulation Retaining Wall Approved By: 71~, guilding Inspector Base Fee Surcharge ~7 ~ I % )L- 'D Plan Review MGES SAC 711 B ~ ~ ` 13 3, IS~ ~ ~Z Citysac 7 1,7 1( 2'/ Utility Connection Charge S&W Permit & Surcharge P ! oa Treatment Plant h TV 0 License Search P~ Copies Other qV Total ETE r Use 4 J City of EaaR r A 7 u e: 31) 3830 Pilot Knob Road t Eagan MN 55122 Date Rece I Phone: (651) 675 -5675 Staff: Fax: (651) 675 -5694 2009 RESIDENTIAL BUILDING PERMIT APPLICATION 9 Date: 'TVA C Site Address: ��sr Q 6 1 l Z-. 2 Tenant: Suite RESIDENT OWNER Name: Phone: 6,S/ 113 Y-.• 2 Fn 3 Address /City Zip: e/-1145E e'fe_. E.4ciiJ /1 N.,s/ Applicant is: X Owner Contractor TYPE OF WORK Description of work: 276CR /1)0 Construction Cost: .3.5"o 421- Multi- Family Building: (Ye No 1J CONTRACTOR Name: License Address: f f City: C._ State: Zip: Phone: Contact Person: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING Minnesota Rules 7670 Category 1 Minnesota Rules 7672 Energy Code Residential Ventilation Category 1 Worksheet New Energy Code Worksheet Category Submitted Submitted (I submission type) Energy Envelope Calculations Submitted In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer Water Contractor: Phone: NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non public if you provide specific reasons that would permit the City to conclude that they are trade secrets. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. x .l'e i cs,Q,, x Applicant's Printed Name Applicant's Signature Page 1 of 3 1 /64 Ste e p le- ChaSC., DO NOT WRITE BELOW THIS LINE e%n SUB TYPES Foundation Fireplace Porch (3- Season) Storm Damage Single Family Garage Porch (4- Season) Exterior Alteration (Single Family) Multi 4 4 Deck Porch (Screen /Gazebo /Pergola) Exterior Alteration (Multi) 01 of Plex Lower Level Pool Miscellaneous Accessory Building WORK TYPES New Interior Improvement Siding Demolish Building* R Addition Move Building Reroof Demolish Interior Alteration Fire Repair Windows Demolish Foundation Replace Repair Egress Window Water Damage Retaining Wall *Demolition of entire building give PCA handout to applicant DESCRIPTION Valuation 3la, Occupancy 3 RC MCES System Plan Review /,q Code Edition a t c47 SAC Units (25 100 Zoning ,PA City Water Census Code 1 y 3 1 j Stories Booster Pump of Units Square Feet J .3 PRV of Buildings Length 7,...s,,,,, Fire Sprinklers Type of Construction -__O Width /6" REQUIRED INSPECTIONS Footings (New Building) Sheetrock f Footings (Deck) Final C.O. Required Footings (Addition) Final No C.O. Required Foundation HVAC Drain Tile Other: Roof: _Ice Water Final Pool: Footings _Air /Gas Tests _Final Framing Siding: _Stucco Lath Stone Lath Brick Fireplace: Rough In Air Test Final Windows Insulation Retaining Wall Meter Size: Radon Control Erosion Control Reviewed By: Building Inspector RESIDENTIAL FEES Base Fee 30 Surcharge Plan Review /1/ /9 MCES SAC City SAC Utility Connection Charge S &W Permit Surcharge Treatment Plant Copies TOTAL Page 2 of 3 Certificate of Survey k0 TOLL BROTHERS OF 1400 Corporate Center Curve L Eagan, MN Zip 55121 4826, 4828, 4830 STEEPLECHASE CIRCLE 3:1 Maximum Slopes or Retaining Wail Will Z 5 s Be Required e l, 9- "J :sr., 9$, g$,0.. SAN MH O L L L.L O. N o Q_// I/ t i ki n oo Snitary e wo ux•' 8 7 y Eo s ement per plot n 96 .6 t 9.27 n' 9 SCALE IN FEET 6 6� .Q 9::14.--"-"< to 1` e� .e�9: 12 v 97 1 3 r` 1 4.3` to.. cv _55.19 s i .;vo j INSTALL EROSION pkop. M j .9 I 33.p _t ^fo. 70 SLAC�6ZET� RR SOD ,o ve o, ,I tj eu h 28 Z.$� 1 R 1 1 4.° .1 El y v p LC 1�1 O 15. 4� I o o' 7.1 i 1 t 1 ti6 1 9 01 4.c 0 M .j G h. 96 a 'y6 etoo. ea 9 I t 14�,�/ ,ilt, Center of circ I 0.I 9 a G� 1 P� `t e O pro I 19. 1 b CO 9 `ti i .,1 t t\c I 'i y c :7 Q drivel 1 o 6$ i�� j 10, Wb House 9 1 3.0 I N `a or fi Ifl 91 floor •913.4 4 41 I LQ 56 0 f I NWL�983 elevotio9 977. 4 .v .e N HWL∎t96 .4 AL 1 P I r o I Sn. Water Prop/ 19.0 5 :i i 1 tl riv o► O v 1p co i nv I; elev. 970.0 a rn 'rye .2 ''ap p O o .0 '4740 v y 0 i I AN MH K"f 0 g a r o O E I i j J k fl a 1) 1;9 5 9.0 1 1- u. o 8 c I 1 Vf IJ 1 L. V T L_' 96 5.00 9 1, r a a i ii (1, O 1' -en 4,% s8 I t cell.- 4 to 5 to 1 11241 •0 ni 41.5 f# V 9.8. ev 0 1 BENCHMARK 9sL° r? >tic> gl 6 12 O I l i Nut Hydrant ots 1 and 2 L Top 't 9$b'` =i I g Elevation as 989.17 feet (NGVD 1988) and Utilit 1 Oroineig .y a i Eosement per plat 5' I E JVED s 0 s r' I la i)aw Z' .�i� 1 l EAGAN ENGINEERING DEPT. LEGEND II AREA Iron monument found Drainage I D irection Lot 2, Block 8 Area 19,001 sq. ft. Offset iron II -840- Prop. 10' contours from groding plan q l' -842 Prop. 2' contours from grading plan Total Condo area 703,324 sq. ft. Drainage Utility Eosement Ex san sewer 20% Max. Coverage 140,665 sq. ft. xaoo.o Existing Elevatio Existing storm sewer Foundation Lot 3, Block 6 9073 sq. ft I Existing water Foundation Lot 1, Block 7 9074 sq. ft. P elevation from grade or development Ion 0 Sanitary manhole Foundation Lot 2, Block 7 7106 sq. ft. Q oa Gate valve Foundation Lot 1, Block 8 6676 sq. ft. -840 Existing 10' contours Hydrant Foundation Lot 2, Block 8 6815 sq. ft. -8 42- Existing 2 cont Flared End Section Foundation Lot 5, Block 8 9072 sq. ft. k Total Foundation coverage 47,816 sq. ft. Bearings shown ore assumed Remaining coverage Available 92,849 sq. ft. CITY OF EAGAN PROP ELEVATIONS PROPOSED ELEVATIONS 4826 4828 4830 Lot 2 B I0I( 3 984.7 Gara floor elev. 984.0 Garage floor elev. 984.3 987.1 Top of elev. Top of block elev. S TEEPLECHASE 975.7 978.4 Lowest floor elev. Lowest floor elev. (Lookout), OF EAGAN DRAWN: JAG CHECKED:. 7 iJ Z18 -L288 Drawing WG 0 D File: g Project No 2006 r Subject to easements of record, if any. i a ulUth, N N I herety certify that this survey, plan or report was prepared by 1 Hi bing, N.N. 4 MN me or under my direct upervision and that I om o duly Licensed Mi L. nne t on ako k a, M N M. Land Surveyor under the laws of the State of Minnesota. "2), fel,(_44 LTD Phone: (952) 933 0972 June 15, 2007 Fax: (952; 933 -1153 1q 60 Michael.E. Cannon, MN License No. 40035 Date www.rlk- ku Js i sto.:corrt Revisd: 7 -5 -t)7 City Comments 6110 Blue Circle Dr. Suite #1 ao Minnetonka, MN. 55343 pp Revised: 7-40.L07 City Cem,ments i fF 1 r 64 9fl I1M 7I.l•.li r-r1 I REScheck Software Version 4.0.1 ~ Compliance Certificate Project Title: Medina Model Report Date: 12/13107 Data filename: K:\_ENGINEERING SERVICES\_HVAC DEPT1_Energy Calculations\MN1Steeple Chase of Eagan- Carnage-S ECR1005\Medina-Classic-005-20061 RC. rck Energy Code: 2006 IECC Location: Minneapolis, Minnesota Construction Type: Multifamily Builidng Orientation: Bldg. faces 45 deg. from North Conditionad Floor Area: 2910 ft2 Glazing Area Percentage: 15% Heating Degree Days: 7981 Climate Zone: 5 Construction Site: Owner/Agent: DesignerlContractor: Steeplechase of Eagan - Carriages- SECR Toll Brothers Ina Toll Brothers Inc. 4828 Steeplechase Court 250 Gibraltar Road Eagan, MN 55122 Horsham, PA 19044 Permit # 005 Permit Date: 12/1312007 . . D. Flat Ceiling: Flat Ceiling or Scissor Truss: 1726 44.0 0.0 47 Garagewall: Wood Frame, 16" o.c.: 179 19.0 0.0 10 Orientation: Front Door 5: Solid: 17 0200 3 Orientation: Front Band Joist: Wood Frame, tfi" o.c.: 332 19.0 0.0 20 Orientation: Front Exterior Wall 6": Exterior Wall 6": 1195 19.0 0.0 60 Orientation: Front Window 2: Vinyl Frame:Double Pane wilh Low-E: 151 0.350 53 SHGC: 0.33 Orientation: Front Door 7: Solid: 20 0.200 4 Orientafion: Front Door 8: Glass: 20 0.340 7 SHGC:027 Orientation: Fronl Knee Wall: Wood Frame, 16" o.c.: 60 19.0 0.0 4 Orientation: Front Basement Wall 1: Solid Concrete or Masonry: 424 0.0 10.0 18 Orientation: Back wall height 9.0' Depth below grade: 8.5' Insulation depth: 8.5' Window 3: Vinyl Frame:Double Pane with Low-E: 69 0.350 24 SHGC: 0.33 Orientation: Back Door 9: Glass: 40 0.340 14 SHGC: 0.27 Orientation: Back Floor Over Garage: All-WOOd JoisUTruss:Over Unconditioned 206 44.0 0.0 5 Space: Fumace 1: Forced Hot Air: 92 AFUE Medina Model Page 1 of 5 Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent wiih the 6uilding plans, specifications, and other calculations submiued with ihe permit appliration. The proposeQ uilding has been designed to meet ihe 2006 IECC requirements in REScheck Version 4.0.1 and ro comply with the mandatory requ~r ~I~SPe'~~~p't~&$nl~pd$t~~~ipn Checklist. fication, pr report was prc;parcd by ~jw%6 -Aq~{- (>fLAor me or undermy dired su e' tvame - Tine ar eazn a duly i.icensed Dale F'ro essior.al Engineer under the Project Notes laws of tae StaCe of A~I~anesota. : ~ Elevation: Classic PrintName: SAM. GROSSE Options: 007, 016, 017, 070 B. Leonards Sipatuic: dw Order 19018 Task 67230 Data 4407 Licens #44835 Medina Model Page 2 of 5 REScheck Software Version 4.0.1 Inspection Checklist Date: 12/13/07 Ceilings: ? Flat Ceiling: Flat Ceiling or Scissor Tmss, R-44.0 cavity insulation Comments: Above-Grade Walis: ? Garage wall: Wood Frame, 16" o.c., R-19.0 cavity insulation Commen4s: ? Band Joist: Wood Frame, tfi" o.c., R-19.0 cavity insulation Comments: ? Ettterior Wall 6". Exterior Wall 6", R-19.0 wvity insuiation Comments: ? Knee Wall: Wood Freme, 16" o.c., R-19.0 cavity insulation Comments: Basement walls: 0 Basement Wall 1: Solid Concrete or Masonry, 9.0' ht / 85bg /8.5' insul, R-10.0 continuous insulation Comments: Windows: ? Window 2: Vinyl Frame:DOUble Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes - Frame Type Thermal Break? - Yes - No Comments: ? Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes - Frame 7ype Thermal Break? _ Ves - No Comments: Note: Up to 15 sq.R. of glazed fenestration per dwelling is exempl from U-factor and SHGC requirements. Doors: ? Door 5: Solid, U-faclor: 0.200 Comments: ? Door 7: Solid, U-factor: 0.200 Comments: ? Door 8: Glass, U-factor: 0.340 Comments: ? Door 9: Glass, U-factor: 0.340 Commenis: Floors: ? Floor Over Garage: All-Wood Jois7Truss:Over Unconditioned Space. R-44.0 cavity insulation Commenls: Floor insulation is installetl in permanent contact with the underside of Ihe subfloor decking. Medina Model Page 3 of 5 Heating and Cooling Equipment: ? Furnace 7: Forced Hot Air: 92 AFUE or higher Make and Model Number: ? Air Conditioner 1: Electric Centwl Air 73 SEER or higher Make and Model Number: AirLeakage: n Joints, penetrations, and all other such openings in the building emelope that are sources of air leakage are sealed. Fl Recessed lights are either 1) Type IC rated with enclosures sealedlgasketed against leaks to the ceiling, or 2) Type IC rated and ASTM E283 labeled, or 3) installed inside an air-tight assembly with a 0.5" clearance from combustible materials and a 3" clearance from insulation. Vapor Retarder: El Vapor retarder is installed on the warm-in-winter side of all non-vented framed ceilings, walls, and fioors; or it has been determined that moisture or its freezing will not damage the materials; or other approved means to avoid condensation are provided. Comments: Materials Identification: Fl Materials and equipment are identified so that compliance can be determined. 11 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. F-I Insulation R-values, glazing U-factors, and heating equipment efficiency are clearly marked on the building plans or specifcations. ~ Insulation is installed according to manufacturer's instructions, in substantial wntact with the surtace being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ~ Ducts in unconditioned spaces are insulated to R-S. Fl Ducts in Ooor trusses are insulated to R-6. Duct Construction: cl Air handlers, filter boxes, and duct connections to flanges o( air dishibution system equipment or sheet metal fittings are sealed and mechanically fastened. F-I All joints, seams, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved dosure systems. Tapes and mastics are rated UL 181A or UL 1876. [-I Building framing cavities are not used as supply ducts. Fl Automatic or graviry dampers are installed on all outdoor air intakes and exhausts. r-I Additional requirements for tape sealing and me[al duct crimping are included by an inspaction for compliance with the Intema[ional Mechanical Code. Temperature Controls: ~ Thermoslats exist for each dwelling unit (non-dwelling areas must have one thermostat for each system or zone). A manual or automalic means to partially reslrict or shut off the heating andlor cooling input to each room is provided. Electric Systems: Fl Separate electric meters exist for each tlwelling unit. Heating and Cooling Equipment Sizing: ~ Additional requirements for equipment sizing are included by an inspection for compliance with the International Mechanical Code. Circulating Hot Water Systems: Fl Circulating hot water pipes are insulafed to R-2. F-I Circulating hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Heating and Cooling Piping Insulation: ~ HVAC piping conveying Fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-2. Certificate: D A permanent certificate is provided on or in the elec}ricai tlis[ribution panel listing the predominant insulation R-values; window U-factors; type and efficiency of space-conditioning and water heating equipment. . ~ .............M...__.... Medina Model Page 4 of 5 NOTES TO FIELD: (Building Department Use Only) Medina Model Page 5 of 5 ~ 2006 IECC Energy Efficiency Certificate Ceiling 1 Roof 44.00 Wall 19.00 Floor I Foundation 44.00 Ductwork (unconditioned spaces): Window 0.35 0.33 Door 0.34 0.27 Forced Not Air Furnace 92 AFUE Electric Central Air Conditioner 13 SEER Water Heater: Name: Date: Comments: ~-T LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICA710N • PROPERTY LEGAL: ~o-I Z~~ S'I I ~ ncrF nF SURVEY: ~~s` ~ LATEST REVISION: -)QLO'7 m m c m t U 9 O Z a DOCUMENT STANDARDS • Registered Land Surveyor signature and company ~j ? ? . Building Permit Applicant Jd' ? 0 • Legal description ,g ? ? • Address ',g ? ? • North arrow and scale 0 ? p . House type (rambler, walkout, split wlo, spl'd entry, lookout, etc.) ,e( ? p • Diredional drainage arr(yws with slope/gradient °/a ,g . Proposed/existing sewer and water services & invert elevation p -Z . Streetname- Lade-I 5-fe~p~ec~aSE-l-ane -l°° . ~ O 0 • Driveway (grade 8 width - in RNJ and back of curb, 22' max.) )ff p ? • Lot Square Footage , -0 0 O • Lot Coverage ELEVATIONS 6cistin .z ? ? . Property comers • Top of wrb at the driveway and property line eztensions ~g- • Elevations of any existing adjacent homes ? • Adequate footing depth of structures due to adjacent utility trenches _0 ? ? - . Waterways (pond, stream, etcJ . Prooosed ` ~~J p ~ . Garage floor - G~G~~ P.l~A/~- ? p . Basement floor ~ p ~ . Lowest exposed elevation (walkoutlwindow) - ? 0 • Property comers "t . Front and rear of home at the foundation - ~,pzlM U PONDING AREA (if apolicable) ~ ? p . Easement line ~ p ? . NWL ,B p ? • HWL ,zf ? ? . Pond # designation .Z ? p . Emergency Overflow Elevation 0 ? p . PondlWetland buffer delineation y . Shoreland Zoning Overlay District y ~ • Conservation Easements DIMENSIONS }d' p ? . Lot lineslBearings & dimensions (~aJ~ p~ . Right-of-way and sVeet width (to back of curb) ~ Slwu/ w, S~eePf°-~'a Se G ref~ ?,~f . Proposed home dimensions induding any proposed decks, overhangs greater than 2', porches, etc. (i.e. 211 structures requl~.q PertnanPnt fnotin-~Sel A~P.~-r S~~awn aS • Show all easements of record and any CRy utdities within those easements ,9 p? . Setbacks of proposed structure and sideyard setback of adjacent existing structures ,B ? ? • Retaining wall requirements: Reviewed By: Date 7//0/ol ti/z7/o7 G:/FORMS/Building Pertnit Application Rev. 11-26-04 ~ `?~oll Architecture ~ August 12, 2008 Jon Henson Steeplechase of Eagan - Carriages ~ 4876 Steeplechase Way Eagan, MN 55122 RE: TBI Lots #004, 005 & 006 Dear Jon, For TBI Lots #004, 005, and 006, I have reviewed the revised construction documents for structural integrity. I find no exceptions to the roof framing, floor framing, and foundations including "ta11 wall" assemblies. If you have any questions or concerns, please do not hesitate to call. Sincerely, Toll Brothers, Inc. I he.eby cc-tify t`a21?tis r1an, spwi- fication, or res.urt was p:x:pured by rne o: under my direct sui+ervuiom end tha: Ixr:-i a duly Licensed Rolessinnal Engineer undar the la,vs o,the Sta:e of 44ir.nesata. P:int?;ama: ISA M. GROSSE Signatare_ K'W Date LMLL 1/44935 Lisa M. Grosse, P.E. Assistant Director of Engineering MN License#44835 CC: Rusty Thurlow LMG/II SECR_1tr0016a Structural Integrity EASTERN D[VISION 250 Gibraltar Road o Horsham, PA 19044 m (215) 293-5300 s FAR: (215) 293-5313 PHILADELPH(A m ORLANDO a SCOTTSDALG v DACLA5 o DENVF,R n LOS ANGELES d `r011 ~B1'OtlElS COMP4NY REScheck Software Version 4.1.3 Compliance Certificate Project Title: Medina Model Report Da[e: 08/12l08 Data filename: K:\_ENGINEERING SERVICES\_HVAC DEP-R_Energy Calculations\MN1Steeple Chase of Eagan- Carriage-5 EC R10055Medina-Classic-0O5-Revised_8_12_08. rck Energy Code: 2006 IECC Location: Minneapolis, MinnesoW Construction 7ype: Multifamily Builidng Oriantation: Bldg. faces 45 deg. from North Conditioned Floor Area: 2910 ft2 Glazing Area Percentage: 12% Heating Degree Days: 7981 Climate Zone: 6 Construction Site: OwnedAgent: DesignedContrector. Steeplechase of Eagan - Carriages- SECR Toll Brothers Inc. Toll Brothers Inc. 4828 Steeplechase Court 250 Gibraltar Road Eagan, MN 55122 Horsham, PA 19044 Pertnit # 005 Permit Date: 0811212008 Compliance: 3.3% Better Than Code Maximum UA' 302 Your UA: 292 • . D.. Perimeter . Basement Wall 1: Solid Concrete or Masonry 1190 0.0 10.0 64 Orientation: Back Wall height: 9.0' Depth 6elow grade: 8.5' Insulation dapth: 8.5' Window 3: Vinyl Frame:Double Pane with Low-E 4 0.350 1 SHGC: 0.33 Orientation: Back Door 9: Glass 40 0.340 14 SHGC:027 Orientation: Back . E#enor Wall 6": Wood Frame, 16" o.c. 1195 19.0 0.0 60 Orientation: Front Window 2: Vinyl Frame:Double Pane wilh Low-E 151 0.350 53 SHGC: 0.33 Orientation: Front Door 7: Solid 20 0.200 4 Orientation: Front Door B: Glass 20 0.340 7 SHGC:027 Orientation: Front Knee Wall: Wood Frame, 16" o.c. 60 19.0 0.0 4 Orientation: Front Band Joist: Wood Frame, 16" o.c. 332 19.0 0.0 20 Orientation: Front Garage wall: Wood Frame, 16" o.c. 179 19.0 0.0 10 Orientation: Front Door 5: Solid 17 0200 3 Orienlation: Front Flat Ceiling! Flat Ceiling or Scissor Truss 1726 44.0 0.0 47 Floor Over Garage: All-Wood JoisUTruss:Over Unconditioned 206 44.0 0.0 5 Space Project Title: Medina Model RepoA date: 08/12108 Data filename: K:1_ENGINEERING SERVICES\_HVAC DEP71_Energy Calculations\MN1Steeple Chase of Eagan- Carriage-SECR10051Medina-Classic-ODS-Revised_8_72_OB.rck Page 1 of 5 Fumace 1: Forced Hot Air92 AFUE Air Conditioner t Electric Central Air13 SEER Compliance Statemenf: The proposed building design described here is consistent with the building plans, specifica[ions, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in RESchack Version 4.1.3 and to comply with the mandatory reqWffih@b~ 6sL$d6s ftP4§g7pW1ospea9n Checklist. ficatory or report was prepamd by ~5k ?NoSSG - Aw(- Diftc{-or~ E,,,a [ne or undcrmv directx14mivisapn Name - Title an$ipruiNrem a dcly l.icenyeti oate YroFcssiOnal Engineer under the Project Notes: laws of `WC Sta:e cf h9innesotg. Elevation: Classic Opfions: 007, 016, 017, 029, 070 Fr~nt Natl7et j,I$p jyf. GROSSE t MikeB oland SIgtIStrL'C: A,r~, Order 24218 Task 80725 Date ~ L' ~l44&35 I Project Title: Medina Motlel Report date: 08/12108 I Da[a flaname: Ki ENGWEERING SERVICES\_HVAC DEPIl_Energy Calculations\MN\Steeple Chase of Eagan- Carriage-SECR1005\Medina-Classic-005-Revised_8_12_08.rck Page 2 of 5 1 REScheck Software Version 4.1.3 Inspection Checklist Date: 08/12/08 Ceilings: ? Flat Ceiling: Flat Ceiling or Scissor Truss, R44.0 cavity insulation Commenis: Above-Grade Walls: ? Exterior Wall 6": Exterior Wall 6", R-19.0 cavity insulation Comments: ? Knee Wall: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: ? Band Joist: Wood Freme, 16" o.c., R-19.0 ravity insulation Comments: ? Garage wall: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Basement Walls: ? Basement Wall 1: Solid Concrete or Masonry, 9.0' ht / 8.5' bg / 8.5' insul, R-10.0 continuous insulation Comments: Windows: ? Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without la6eled U-factors, describe features: #Panes - Frame Type Thertnal Break? - Yes - No Comments: ? Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes - Frame Type Thermal Break? - Yes - No Comments: Note: Up to 15 sq.ft. of glazed fenestration per dwelling is exempt 6om U-factor and SHGC requirements. Doors: ? Door 9: Glass, U-factor: 0.340 Comments: ? Door 7: Solid, U-faciw: 0.200 Comments: ? Door 8: Glass, U-factor: 0.340 Comments: . ? Door 5: Solid, U-factor: 0200 Comments: Floors: ? Floor Over Garage: All-Wood JoisVTruss:Over Unconditioned Space, R-44.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the untlerside of the subfloor decking. Heating and Cooling Equipment: Project Titte: Medina Model ~ RepoA date: 08112l08 Dffia filename: K:\_ENGINEERING SERVICES\ HVAC DEPII_Energy Calculations\MN15teeple Chase of Eagan- Carriage-SECR10051Medina-Classic-005-Revised_8_12_OB.rck Page 3 of 5 ? Furnace 1: Forced Hot Air 92 AFUE or higher Make and Model Number: ? Air Conditioner 1: Electric Centrel Air: 13 SEER or higher Make and Model Number: Air Leakage: n Joints, penetrations, and all other such openings in the 6uilding envelope that are sources of air leakage are sealed. ~ Recessed lights are either 1) Type IC rated with enclosures sealed/gasketed against leaks lo Ihe ceiling, or 2) Type IC rated and ASTM E2831abeled, or 3) installed inside an air-tight assembly with a 0.5" clearance from combustible matenals and a 3" clearance hom insulation. Vapor Retarder: ~ Vapor retarder is installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors; or it has been determined that moisture or its freezing will not damage the materials; or other approved means to avoitl condensalion are provided. Comments: Materials Identification: ~ Materials and equipment are identified so that compliance can 6e determined. F-1 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. n Insulation R-values, glazing U-tactors, and heating equipment eTficiency are clearty marked on the building plans or specifications. F-1 Insulation is installed according to manufacturer's ins[ructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value withoul compressing the insulation. Ductlnsulatlon: F-I Ducts in unconditioned spaces or outside the builtling are insulaled to at least R-8. Fl Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to a[ least R-6. Duct Construction: ~ Air handlers, flter boxes, and duct connections to Flanges of air distribution system equipment or shest metal fittings are sealed and mechanically (astened. ~ All joints, seams, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved closure systems. Tapes and mastics are reted UL 181A or UL 181 B. 0 Building framing cavities are not used as supply ducts. ~ Automatic or greviry dampers are installed on all outdoor air intakes and exhausts. ~ Additional requirements for tape sealing and metal ducf crimping are included by an inspection for compliance with the International Mechanical Code. Temperature Controls: ~ Thermostats exist for each dwelling unit (non-dwelling areas must have one thermostat for each system or zone). A manual or automatic means to partially resirict or shut off the heating andlor cooling input to each room is providad. Electric Systems: ~ Separate electric maters ezist for each dwelling unit. Heating and Cooling Equipment Sizing: F-I Additionai requirements for equipment sizing are included by an inspection for compliance with the International Mechanical Code. Circulating Hot Water Systems: Q Circulating hot water pipes are insulated to R-2. F I Circulating hot water systems include an automatic or accessible manual switch to tum off the circulating pump when ihe system is not in use. Heating and Cooling Piping Insulation: F-I HVAC piping conveying fluids a6ove 105 degrees F or chilled fluids below 55 degrees F are insulated to R-2. Certifcate: F-I A permanent certificate is provided on or in the electrical disiribution panel listing the predominant insulation R-values; window U-factors: rype and eificiency of space-conditioning and water heating equipment. NOTES TO FIELD: (Building Department Use Only) Project Title: Medina Model Report date: 08/12108 Data filename: K:\_ENGINEERING SERVICES\_HVAC DEP71_Energy Calculations\MMSteeple Chase of Eagan- Carriage-SECR1005\Medina-Classic-005-Revised_8_12_08.rck Page 4 of 5 I~I Projecl Title: Medina Model ^ Report date: 08112108 Data filename: K:\_ENGINEERING SERVICES\_HVAC DEPT\_Energy Calculations\MN\Steeple Chase of Eagan- Carnage-SECR\005\Medina-Classic-005-Revised 8_72_08.rck Page 5 of 5 ' ONK 2 6 1 C nergY Efficiency Certificate Ceiling ! Roof 44.00 Wall 19.00 Floor 1 Foundatian 10.00 Ductwork (unconditloned spaces): eo Window 0.35 033 Door 0.3-0 027 MIMMINIMME= Forced Hot Alr Fumace 92 AFUE Electric Centrel Air Cond'rtioner 13 SEER Water Heater: Name: Date: Comments: Address: 4828 Steeplechase Circle Zip: 55122 Per it•79060 THE FOLLOWING ITEMS WERE/WERE NOT COMPLETE AT F[IYAL INSPECTION ON :~(I) vlV 0 Yes No Comments Final grade - 6" from sidin Permanent ste s- aza e Permanent ste s- main entry Permanent drivewa Permanent as Retaining Wall or 3:1 Max Slo e Sod/Seeded lawn Trail/curb damage Porch Lower level finish Deck Fire lace • Verify with your builder that roof test caps from the pWmbing system have been removed. • Tum off water supply to the outside lawn faucets before freeze potential exisu. • Call the Ciry's Engineering Department at 651-675-5646 prior to working in right-of-way or installing irrigation system. ~ BUILDING INSPECTOR: . GBldg Insp/Formy2007/Checklisu Date: 6/11/07 Revision Date: 6/11/07 New Construction Site Infortnation Address 1: 4828 Steeplechase Circle Project Steeplechase of Eagan Address 2: Lot: 5 Biock: 8 City: Eagan County: Subdivision: Application Information Businass Name: Ray N Welter HVAC MN Contractor License Contact Person: JOE Office Ph: 612-8256867 Fax: Cell Ph: Address 1:' 4637 Chicago Ave. So. City: MPLS. State: MN. Zip Code: 55407 House Details Square Feet: 3767 sq. ft. Avg. Ceiling Ht: 10 ft. Number of Bedrooms: 2 Ventilation : Balanced Total Ventilation Capacity : 165 cfm. Minimum Continuous Ventilation :45cfm. Intermittent Ventilation: 120 cfm. Combustion Aaaliance Water Heater: Power Vent Input BTUs: 80,000 Independently Vented Fumace/Boiler: Direct VenUSealed Combustion Input BTUs: 80,000 Independently Vented Other Combustion Aoqliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No 5olid Fuel Appliance(s): No Exhaust Epuipment Continuous Exhaust Ventilation Capacity (cfm): NA Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 300 Make-Ua Air No Make-Up Air Required by Code Combustion Air Minimum Combustion Air Requirements Met. Appiicant Name (print): Signature/Date/• Q r C/~, Code Official (print): Signature/Dat : (D 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1 PERMIT City of Eagan Permit Type:Building Permit Number:EA179750 Date Issued:10/19/2022 Permit Category:ePermit Site Address: 4828 Steeplechase Cir Lot:2 Block: 8 Addition: Steeplechase Of Eagan PID:10-72540-10-005 Use: Description: Sub Type:Reroof Work Type:Replace Description:Includes Skylight Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. If water damage is encountered, please call (651) 675-5675 to schedule a site visit to verify the extent of the damage. Any repairs must be inspected prior to covering. The inspector will determine if an additional permit will be required to repair the water damage. Valuation: 5,000.00 Fee Summary:BL - Base Fee $5K $118.00 0801.4085 Surcharge - Based on Valuation $5K $2.50 9001.2195 $120.50 Total: This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Lawrence L Lesniak 4828 Steeplechase Cir Eagan MN 55122 Parkway Custom Construction Llc 1303 S Frontage Rd Suite 199 Hastings MN 55033 (651) 480-3797 Applicant/Permitee: Signature Issued By: Signature